Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GIGABYTE GS-R12T102. We hope that this GIGABYTE GS-R12T102 user guide will be useful to you.
Lastmanuals help download the user guide GIGABYTE GS-R12T102.
Detailed instructions for use are in the User's Guide.
[. . . ] GIGABYTE GS-R12T4H2-RH 1U Rack Mount Server Service Guide
Dual Intel® Xeon LGA1366 Processor Serverboard Rev. 1. 0
Preface
Before using this information and the product it supports, please read the following general information. This Service Guide provides you with all technical information relating to the BASIC CONFIGURATION decided for GIGABYTE's "global" product offering. To better fit local market requirements and enhance product competitiveness, your regional office MAY have decided to extend the functionality of a machine (e. g. [. . . ] Connect the keyboard and mouse devices to this port. Connect a RJ-45 jack to this port to link to a 10/100/1000 Megabit Ethernet LAN. Connect the monitor device to this port. Connect a RJ-45 jack to this port to link to a 10/100 LAN. Connect USB devices to these four ports. Remove this cover before installing a PCIE card. Remove this cover before installing a PCIE card.
30
LED Description
Front Panel LED Indicator
6 5 4 3 2 1
No 1
Indicator Color Power status Green Green N/A
State On Blink Off
Description System has power applied to it or ACPI S0 state System is in ACPI S1 state (sleep mode) System is not powered on or in ACPI S5 state (power off) System is in ACPI S4 state (hlbernate mode) System identification is active System identification is disabled Running or normal operation System degraded due to CPU or DIMM error Critical or non-recoverable condition (Power module or voltage power supply failure or critical temperature) Non-critical condition System not ready May indicate the following: POST error NMI event Processor or terminator missing HDD access No access
2 3
System ID Blue System status Green Green Amber
On Off On Blink On
Amber N/A
Blink Off
4
HDD activity
Green N/A
Blink Off
31
GS-R12T4H2-RH Rack Mount Server
No 5
Indicator Color LAN1 activity Green Green Green Green
State On Blink On Blink
Description Link between system and network or no access Network access Link between system and network or no access Network access
6
LAN2 activity
32
GS-R12T4H2-RH Rack Mount Server
LAN port LED Indicator
No 1 Name Speed indicator Color N/A Green Orange
State Off On On Description 10Mbps connection 100Mbps connection 1000Mbps connection Note: The server management port does not support 1000Mbps connection Active connection Transmit or receive connection
2
Link/activity Green indicator Green
On Blink
33
LED Description
Hard Disk Drive LED Description
Description HDD Prsent HDD access HDD failure HDD removed HDD connected and rebuilding data HDD locate SAS/SATA HDD indicator Green On Blink (4Hz) Off Off On Blink (4Hz) Red Off Off On On Blink (1 Hz) Blink (4Hz)
34
GS-R12T4H2-RH Rack Mount Server
GC-BS14U-RH Back plane board Components
13 18 19 17 11 16 15 12
9
10
7 8
2
14
5 6
3 4 1
20
24
21
25
22
26
23
27
No 1 2 3~14 15 16 17 18 19 20~23 24~27
Code P2 P1 SF1~SF12 CD-ROM_PWR1 J3 J2 SGPIO_JP2 SGPIO_JP1 SATA0~SATA3 SAS0~SAS
Description Power Connector (14-pin) Power Connector (14-pin) System fan connectors #1~12 CD-ROM power connector CD-ROM power connector SMBUS connector from M/B to B/P SGPIO connector from RAID card SGPIO connector from Enclosure IC(Motherboard) SATA cable connectors #0~3 HDD connector #0~3 (SAS & SATA)
35
GS-R12T4H2-RH Rack Mount Server
System Block Diagram
DDR3 DDR3 DDR3 DDR3
RMII
DDR3
DDR3
DDR3
CH0
DDR3
DDR3
DDR3
DDR3
CH1
LGA1366 Port 1
QPI
LGA1366 Port 1
QPI
CH2
DDR3
DDR3
DDR3
DDR3
PCIE x16 (x8 bandwidth) PCIE X8 (x8 bandwidth) SODIMM (x4 bandwidth) PCI slot (3. 3V)
PCIE x8 GEN2
INTEL Tylersburg-24D IOH
CLINK ESI
PCIEx4
Kawela
RMI ID Switch
GLAN port x2 COM2 COM1 Rear VGA BCM5221
KVM LAN PS/2
PCIE x8 GEN2
PILOT II
LPC USB x 1 *2 (USB0/1) PCIE x1 USBX1 *4
PCIE x4 GEN1 PCI SATAII
INTEL ICH10R
ITE8720
USB port x4
USBX1 *2 USBX1 *2
Front USB1 Front USB2
SATA1
SATA2
SATA3
SATA4
SATA5
SATA6
36
DDR3
DDR3
CPU1 Nehalem-EP Processor
QPI
CPU2 Nehalem-EP Processor
DDR3
VRD 11. 1
VRD 11. 1
GS-R12T4H2-RH Rack Mount Server
Connector Icon Description
Suggest Icon Description Keyboard Mouse VGA
COM LAN USB
37
Motherboard Compononts
Motherboard Placement and Jumper Setting
GA-7TTSE-RH Motherboard Component
15 12
8 11 5
21
6 4
13
7
16
14
3 2 17
22
10 18 19
9
20
24 23
1
38
GS-R12T4H2-RH Rack Mount Server
Item 1. 24.
Component Processor 1 socket Processor 2 socket SATA data cable cable connectors USB connector for internal USB (Tape device) CMOS battery 3-pin IPMB connector LPT_DEBUG connector Serial port connector HDD back plance borad connector Front panel connector SO-DIMM I/F PCI 32/33 MHz slot PCI- E x12 slot PCI- E x8 slot Rear I/O ports DDR3 DIMM slots x 9 for secondary processor DDR3 DIMM slots x 9 for primary processor 8-pin Power connector for primary processor 8-pin Power connector for secondary processor 24-pin Power connector SGPIO connector 1 for ICH10R SGPIO connector 2 for RAID card System fan connector 1 for back plance board System fan connector 2 for back plance board
39
Jumper Setting
Jumper Setting
6
1 2 3 4 5
7
1 ) BIOS_RVCR1 (BIOS Revocery jumper)
1 1
1-2 close: Normal operation. (Default setting) 2-3 close: Enable BIOS Recovery function.
2 ) CLR_CMOS1 (Clear CMOS jumper)
You may clear the CMOS data to its default values by this jumper. Default value doesn't include the "Shunter" to prevent from improper use this jumper. To clear CMOS, temporarily short 2-3 pin.
1 1
1-2 close: Normal operation (Default setting) 2-3 close: Clear CMOS
40
GS-R12T4H2-RH Rack Mount Server
3 ) CLR_RTC1 (Clear RTC jumper)
1 1
1-2 close: Normal operation. (Default setting) 2-3 close: Clear RTC status
4 ) ME_ENABLE (BMC Selection jumper)
1 1
1-2 Close: Normal operation. (Default setting) 2-3 Close: Enable BMC function.
5 ) PASS_DIS1 (Skip Supervisor password jumper)
1 1
1-2 Close: Normal operation. (Default setting) 2-3 Close: Clear Supervisor Password in BIOS setup menu.
6/7 ) JP_STRAP2/ JP_STRAP8 (PilotII firmware upgrade jumper)
JP_STRAP2
1 1 1
JP_STRAP8
1 1 1
Descripeion Boot from BMC BOOT SPI Interface. (Default setting) Boot From BMC LPC BOOT ROM interface. Boot From internal ROM(Scratchpad Registers) Boot From internal ROM(Scratchpad Registers)
1
1
41
Jumper Setting
Expansion Card Components Description
The two riser cards installed in the PCI riser card bracket assembly povides support for both fullheoght and low-profile expansion cards. Full height and low profile PCI Express riser cards
1
2
No. 1 2
Code PCI-E_X16_1 PCI-E_2
Description Full-height riser slot Low-profile riser slot
42
GS-R12T4H2-RH Rack Mount Server
BIOS Setup
BIOS (Basic Input and Output System) includes a CMOS SETUP utility which allows user to configure required settings or to activate certain system features. The CMOS SETUP saves the configuration in the CMOS SRAM of the motherboard. When the power is turned off, the battery on the motherboard supplies the necessary power to the CMOS SRAM.
ENTERINGSETUP
When the power is turned on, press the <F2> button during the BIOS POST (Power-On Self Test) will take you to the CMOS SETUP screen. You can enter the BIOS setup screen by pressing "Ctrl + F1".
CONTROLKEYS
<> <> <> <> <Esc> Move to previous item Move to next item Move to the item in the left hand Move to the item in the right hand Main Menu - Quit and not save changes into CMOS Status Page Setup Menu and Option Page Setup Menu - Exit current page and return to Main Menu <+/PgUp> Increase the numeric value or make changes <-/PgDn> <F1> <F2> <F3> <F4> <F6> <F7> <F8> <F9> <F10> Decrease the numeric value or make changes General help, only for Status Page Setup Menu and Option Page Setup Menu Reserved Reserved Reserved Reserved Reserved Reserved Load the Optimized Defaults Save all the CMOS changes, only for Main Menu
43
BIOS Setup
GETTINGHELP Main Menu
The on-line description of the highlighted setup function is displayed at the bottom of the screen.
Status Page Setup Menu / Option Page Setup Menu
Press F1 to pop up a small help window that describes the appropriate keys to use and the possible selections for the highlighted item. To exit the Help Window press <Esc>. [. . . ] On-board COM A On-board COM B Disabled Use Serial Port A as the COM port address. Use Serial Port B as the COM port address. (Default setting)
Flow Control
This option provide user to enable the flow control function. (Default setting)
Baud Rate
77
BIOS Setup This option allows user to set the specified baud rate. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GIGABYTE GS-R12T102
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GIGABYTE GS-R12T102 will begin.