User manual GIGABYTE GS-R12T4H2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GIGABYTE GS-R12T4H2. We hope that this GIGABYTE GS-R12T4H2 user guide will be useful to you.

Lastmanuals help download the user guide GIGABYTE GS-R12T4H2.


Mode d'emploi GIGABYTE GS-R12T4H2
Download
Manual abstract: user guide GIGABYTE GS-R12T4H2

Detailed instructions for use are in the User's Guide.

[. . . ] GIGABYTE GS-R12T4H2-RH 1U Rack Mount Server Service Guide Dual Intel® Xeon LGA1366 Processor Serverboard Rev. 1. 0 Preface Before using this information and the product it supports, please read the following general information. This Service Guide provides you with all technical information relating to the BASIC CONFIGURATION decided for GIGABYTE's "global" product offering. To better fit local market requirements and enhance product competitiveness, your regional office MAY have decided to extend the functionality of a machine (e. g. [. . . ] Connect the keyboard and mouse devices to this port. Connect a RJ-45 jack to this port to link to a 10/100/1000 Megabit Ethernet LAN. Connect the monitor device to this port. Connect a RJ-45 jack to this port to link to a 10/100 LAN. Connect USB devices to these four ports. Remove this cover before installing a PCIE card. Remove this cover before installing a PCIE card. 30 LED Description Front Panel LED Indicator 6 5 4 3 2 1 No 1 Indicator Color Power status Green Green N/A State On Blink Off Description System has power applied to it or ACPI S0 state System is in ACPI S1 state (sleep mode) System is not powered on or in ACPI S5 state (power off) System is in ACPI S4 state (hlbernate mode) System identification is active System identification is disabled Running or normal operation System degraded due to CPU or DIMM error Critical or non-recoverable condition (Power module or voltage power supply failure or critical temperature) Non-critical condition System not ready May indicate the following: POST error NMI event Processor or terminator missing HDD access No access 2 3 System ID Blue System status Green Green Amber On Off On Blink On Amber N/A Blink Off 4 HDD activity Green N/A Blink Off 31 GS-R12T4H2-RH Rack Mount Server No 5 Indicator Color LAN1 activity Green Green Green Green State On Blink On Blink Description Link between system and network or no access Network access Link between system and network or no access Network access 6 LAN2 activity 32 GS-R12T4H2-RH Rack Mount Server LAN port LED Indicator No 1 Name Speed indicator Color N/A Green Orange State Off On On Description 10Mbps connection 100Mbps connection 1000Mbps connection Note: The server management port does not support 1000Mbps connection Active connection Transmit or receive connection 2 Link/activity Green indicator Green On Blink 33 LED Description Hard Disk Drive LED Description Description HDD Prsent HDD access HDD failure HDD removed HDD connected and rebuilding data HDD locate SAS/SATA HDD indicator Green On Blink (4Hz) Off Off On Blink (4Hz) Red Off Off On On Blink (1 Hz) Blink (4Hz) 34 GS-R12T4H2-RH Rack Mount Server GC-BS14U-RH Back plane board Components 13 18 19 17 11 16 15 12 9 10 7 8 2 14 5 6 3 4 1 20 24 21 25 22 26 23 27 No 1 2 3~14 15 16 17 18 19 20~23 24~27 Code P2 P1 SF1~SF12 CD-ROM_PWR1 J3 J2 SGPIO_JP2 SGPIO_JP1 SATA0~SATA3 SAS0~SAS Description Power Connector (14-pin) Power Connector (14-pin) System fan connectors #1~12 CD-ROM power connector CD-ROM power connector SMBUS connector from M/B to B/P SGPIO connector from RAID card SGPIO connector from Enclosure IC(Motherboard) SATA cable connectors #0~3 HDD connector #0~3 (SAS & SATA) 35 GS-R12T4H2-RH Rack Mount Server System Block Diagram DDR3 DDR3 DDR3 DDR3 RMII DDR3 DDR3 DDR3 CH0 DDR3 DDR3 DDR3 DDR3 CH1 LGA1366 Port 1 QPI LGA1366 Port 1 QPI CH2 DDR3 DDR3 DDR3 DDR3 PCIE x16 (x8 bandwidth) PCIE X8 (x8 bandwidth) SODIMM (x4 bandwidth) PCI slot (3. 3V) PCIE x8 GEN2 INTEL Tylersburg-24D IOH CLINK ESI PCIEx4 Kawela RMI ID Switch GLAN port x2 COM2 COM1 Rear VGA BCM5221 KVM LAN PS/2 PCIE x8 GEN2 PILOT II LPC USB x 1 *2 (USB0/1) PCIE x1 USBX1 *4 PCIE x4 GEN1 PCI SATAII INTEL ICH10R ITE8720 USB port x4 USBX1 *2 USBX1 *2 Front USB1 Front USB2 SATA1 SATA2 SATA3 SATA4 SATA5 SATA6 36 DDR3 DDR3 CPU1 Nehalem-EP Processor QPI CPU2 Nehalem-EP Processor DDR3 VRD 11. 1 VRD 11. 1 GS-R12T4H2-RH Rack Mount Server Connector Icon Description Suggest Icon Description Keyboard Mouse VGA COM LAN USB 37 Motherboard Compononts Motherboard Placement and Jumper Setting GA-7TTSE-RH Motherboard Component 15 12 8 11 5 21 6 4 13 7 16 14 3 2 17 22 10 18 19 9 20 24 23 1 38 GS-R12T4H2-RH Rack Mount Server Item 1. 24. Component Processor 1 socket Processor 2 socket SATA data cable cable connectors USB connector for internal USB (Tape device) CMOS battery 3-pin IPMB connector LPT_DEBUG connector Serial port connector HDD back plance borad connector Front panel connector SO-DIMM I/F PCI 32/33 MHz slot PCI- E x12 slot PCI- E x8 slot Rear I/O ports DDR3 DIMM slots x 9 for secondary processor DDR3 DIMM slots x 9 for primary processor 8-pin Power connector for primary processor 8-pin Power connector for secondary processor 24-pin Power connector SGPIO connector 1 for ICH10R SGPIO connector 2 for RAID card System fan connector 1 for back plance board System fan connector 2 for back plance board 39 Jumper Setting Jumper Setting 6 1 2 3 4 5 7 1 ) BIOS_RVCR1 (BIOS Revocery jumper) 1 1 1-2 close: Normal operation. (Default setting) 2-3 close: Enable BIOS Recovery function. 2 ) CLR_CMOS1 (Clear CMOS jumper) You may clear the CMOS data to its default values by this jumper. Default value doesn't include the "Shunter" to prevent from improper use this jumper. To clear CMOS, temporarily short 2-3 pin. 1 1 1-2 close: Normal operation (Default setting) 2-3 close: Clear CMOS 40 GS-R12T4H2-RH Rack Mount Server 3 ) CLR_RTC1 (Clear RTC jumper) 1 1 1-2 close: Normal operation. (Default setting) 2-3 close: Clear RTC status 4 ) ME_ENABLE (BMC Selection jumper) 1 1 1-2 Close: Normal operation. (Default setting) 2-3 Close: Enable BMC function. 5 ) PASS_DIS1 (Skip Supervisor password jumper) 1 1 1-2 Close: Normal operation. (Default setting) 2-3 Close: Clear Supervisor Password in BIOS setup menu. 6/7 ) JP_STRAP2/ JP_STRAP8 (PilotII firmware upgrade jumper) JP_STRAP2 1 1 1 JP_STRAP8 1 1 1 Descripeion Boot from BMC BOOT SPI Interface. (Default setting) Boot From BMC LPC BOOT ROM interface. Boot From internal ROM(Scratchpad Registers) Boot From internal ROM(Scratchpad Registers) 1 1 41 Jumper Setting Expansion Card Components Description The two riser cards installed in the PCI riser card bracket assembly povides support for both fullheoght and low-profile expansion cards. Full height and low profile PCI Express riser cards 1 2 No. 1 2 Code PCI-E_X16_1 PCI-E_2 Description Full-height riser slot Low-profile riser slot 42 GS-R12T4H2-RH Rack Mount Server BIOS Setup BIOS (Basic Input and Output System) includes a CMOS SETUP utility which allows user to configure required settings or to activate certain system features. The CMOS SETUP saves the configuration in the CMOS SRAM of the motherboard. When the power is turned off, the battery on the motherboard supplies the necessary power to the CMOS SRAM. ENTERINGSETUP When the power is turned on, press the <F2> button during the BIOS POST (Power-On Self Test) will take you to the CMOS SETUP screen. You can enter the BIOS setup screen by pressing "Ctrl + F1". CONTROLKEYS <> <> <> <> <Esc> Move to previous item Move to next item Move to the item in the left hand Move to the item in the right hand Main Menu - Quit and not save changes into CMOS Status Page Setup Menu and Option Page Setup Menu - Exit current page and return to Main Menu <+/PgUp> Increase the numeric value or make changes <-/PgDn> <F1> <F2> <F3> <F4> <F6> <F7> <F8> <F9> <F10> Decrease the numeric value or make changes General help, only for Status Page Setup Menu and Option Page Setup Menu Reserved Reserved Reserved Reserved Reserved Reserved Load the Optimized Defaults Save all the CMOS changes, only for Main Menu 43 BIOS Setup GETTINGHELP Main Menu The on-line description of the highlighted setup function is displayed at the bottom of the screen. Status Page Setup Menu / Option Page Setup Menu Press F1 to pop up a small help window that describes the appropriate keys to use and the possible selections for the highlighted item. To exit the Help Window press <Esc>. [. . . ] On-board COM A On-board COM B Disabled Use Serial Port A as the COM port address. Use Serial Port B as the COM port address. (Default setting) Flow Control This option provide user to enable the flow control function. (Default setting) Baud Rate 77 BIOS Setup This option allows user to set the specified baud rate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GIGABYTE GS-R12T4H2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GIGABYTE GS-R12T4H2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag