[. . . ] This symbol indicates the possibility of injury or damage to properties only.
s Meanings of symbols used in this manual are as shown below.
Be sure not to do this. Be sure to follow the instructions.
WARNING
Plug in the power plug properly.
· Otherwise, it will cause electric shock or fire due to heat generation.
Do not operate or stop the unit by inserting or pulling out the power plug.
· It will cause electric shock or fire due to heat generation.
Do not damage or use an unspecified power cord.
· It will cause electric shock or fire. · If the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
Do not modify power cord length or share the outlet with other appliances.
· It will cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
· It will cause electric shock.
Do not direct air flow at room occupants only.
· This could lead to health problems.
3
Safety Precautions
When the air filter is to be removed, do not touch the metal parts of the unit.
· They are sharp and may cause an injury.
Do not clean the air conditioner with water.
When the unit is to be cleaned, switch the unit off, and unplug it.
· Since the fan rotates at high speed during operation, it may cause an injury.
· Water may enter the unit and degrade the insulation. It may cause an electric shock.
Do not operate the unit without the air filter or when the front intake grille has been removed.
· It could cause dust to accumulate on the heat exchanger.
Do not put a pet or house plant where it will be exposed to direct air flow.
· This could injure the pets or plants.
Do not use for special purposes.
· Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. [. . . ] The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. The top of the wood strip should be approximately 3/4" higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside. Install a second wood strip (approximately 6" long by 11/2" wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as shown Fig. If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1", two of wood strips are not necessary.
INNER SILL
WOOD STRIP MOUNTED ON TOP OF INNER SILL
1" MAX.
/4" CLEARANCE STORM WINDOW FRAME
3
Features and Installation
INNER SILL OUTER SILL INDOORS
Fig. 5-1
WOOD STRIP FOR L BRACKET OUTER SILL
OUTDOORS
INDOORS
Fig. 5-2
OUTDOORS
Installation
HARDWARE
TYPE A: 11EA (SHORT SCREW) 10mm TYPE B: 5EA (WOOD SCREW) 16mm TYPE C: 3EA (L BRACKET)
TYPE D: 1EA (SEAL STRIP)
TYPE E: 1EA (SASH SEAL)
TYPE F: 2EA (GUIDE PANEL)
TYPE G: 1EA (SUPPORT BRACKET)
(Adhesive backed)
(Not adhesive backed)
8
A. Insert the guide panels into the guides of the air conditioner. Fasten the curtains to the unit with screws (TYPE A), as shown Fig. Cut the adhesive-backed seal strip (TYPE D) to the window width. Remove the backing from the seal strip and attach the seal strip to the underside of the bottom window. LOCATING UNIT IN WINDOW Open the window and mark center line on the center of the inner sill, as shown in Fig. Install the L brackets behind the inner window sill, with short side of bracket as shown. The bracket helps to hold unit securely in place. Be sure to place bracket edge flush against back of inner sill. 7
CENTER LINE
INNER SILL
ROOM SIDE
Fig. 8
INNER SILL TYPE A OUTER SILL INSIDE
CAUTION
During the following step, hold unit firmly until window sash is lowered to top channel behind side panel frames. Personal injury or property damage may result if unit falls from window. INSTALL THE AIR CONDITIONER IN THE WINDOW a. Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the L bracket. IMPORTANT : When the air conditioner drops into the L bracket, the air conditioner will be centered in window opening as shown in Fig. [. . . ] Repairs when your LG product is used in other than normal, single-family household use. Damage resulting from accident, alteration, misuse, abuse, or improper installation. Therefore, these costs are paid by the consumer. If the product is installed outside the normal service area, any cost of transportation involved in the repair of the product, or the replacement of a defective parts, shall be borne by the owner. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GOLDSTAR R5207
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.