[. . . ] 15V826 Gun Flush Box Kit
312784C
ENG
Kit includes parts to install a Graco Gun Flush Box in a ProMix® 2KS Proportioning System. Bare Gun Flush Box is approved for use in explosive atmospheres. See manual 309227.
100 psi (0. 7 MPa, 7 bar) Maximum Air Inlet Pressure Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
Related Manuals
Contents
Related Manuals . [. . . ] The other end must be sized to mate with your main air supply line.
Install AFS#2 here (if used).
K L 105 103
TI13350a
2 1
102 104 105
102
Install Air Flow Switch on Back of Fluid Station Panel
1
User supplied air inlet fitting (L) must be 1/4 npt(m) to mate with bulkhead fitting (105). Route AFS wires through this strain relief (K) to Fluid Station Control Board. Connect AFS#1 wires to J1 pins 1 and 2 on Fluid Station Control Board. Connect AFS#2 wires to J1 pins 3 and 4 on Fluid Station Control Board.
TI15099a
2
Back View of Fluid Station Panel
3
4
J1
1 2 3 4
3 4
AFS Wire Connections at Fluid Station Control Board
TI13347a
FIG. 3: Installing the Air Flow Switch
312784C
7
Installation
8
312784C
Installation
Install the Pressure Switch
2. Position the pressure switch (107) as shown. Install the bulkhead fitting (108) to secure the switch to the side of the panel. Install the tubing adapter (118) in the bulkhead fitting. Route the pressure switch wires through the designated strain relief (K, see FIG. Connect PS#1 wires to J1 pins 7 and 8 on the Control Board. Connect PS#2 wires (if used) to J1 pins 9 and 10. (4 mm) OD air tube from the tube adapter (118) to the A port on the bottom of the gun flush box. 8.
NOTE: Each gun flush box includes one pressure switch (PS). Install the pressure switch in the fluid station panel, as shown in FIG. If you are using a second gun flush box, install its pressure switch next to the first switch, as shown. Follow Before Installing, page 5.
118 108 K
2
107
TI14162a
Install PS#2 here (if used).
107
Install Pressure Switch on Back of Fluid Station Panel
J1
Back View of Fluid Station Panel
2
TI15099a
7 8 9 10
3 4 3
Route PS wires through this strain relief (K) to Fluid Station Control Board. Connect PS#1 wires to J1 pins 7 and 8 on Fluid Station Control Board. Connect PS#2 wires to J1 pins 9 and 10 on Fluid Station Control Board.
PS Wire Connections at Fluid Station Control Board FIG. 4: Installing the Pressure Switch
312784C
TI13347a
4
9
Installation
Gun Flush Box Solenoid
2. Install the solenoid valve (109) in the correct position as shown in FIG. Connect the GFB#1 solenoid wires to J8 pin 3 (red) and 4 (black) on the Control Board. Connect GFB#2 wires (if used) to J8 pin 1 (red) and 2 (black). [. . . ] Minimum Air Flow required to activate Air Flow Switch 100 psi (0. 7 MPa, 7 bar)
312784C
19
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO GUN FLUSH
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO GUN FLUSH will begin.