Huskyt Leak Detectors
For use with air operated double diaphragm pumps. Shuts off pump and prevents fluid from escaping. Not for use in explosive atmospheres.
60 psi (0. 41 MPa, 4. 1 bar) Maximum Incoming Air Pressure
Model 239080, Series A
polypropylene housing, PVC wetted parts Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.
Contents
Symbols . [. . . ] 3
W
TI14900a
6
308702
Notes
308702
7
Operation
Pressure Relief Procedure Operating Instructions
See Parts Drawing on page 13. D When compressed air is applied to the pump and the leak detector, the pump operates as it would under normal operating conditions. Exhaust air from the pump flows into the leak detector and out of the leak detector silencer (R). D If the pump diaphragm leaks, liquid may enter the pump's air exhaust and be carried to the leak detector. When liquid accumulates in the leak detector, the float (4) rises, and air flow is diverted to a different hose in the the three-way valve (M). As a result, air pressure is removed from the shut-off valve (1), which closes it and stops the pump. When the leak detector triggers a pump shutdown, you should suspect that a pump diaphragm has failed, and you should respond as follows: 1. Shut off all air to the pump and the leak detector.
WARNING
PRESSURIZED EQUIPMENT HAZARD The equipment stays pressurized until pressure is manually relieved. To reduce the risk of serious injury from pressurized fluid, accidental spray, or splashing fluid, follow this procedure whenever you: D D D D Are instructed to relieve pressure Stop pumping Check, clean, or service any system equipment Install or clean fluid nozzles
1. Open the fluid drain valve to relieve all fluid pressure, and have a container ready to catch the drainage.
WARNING
TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. D Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer's warnings.
2. Drain the liquid from the leak detector through the drain valve (B) into a suitable container, depending on the liquid being pumped. If the liquid that comes out of the drain valve (B) is only water condensation, no corrective action is necessary. Close the drain valve, open the fluid supply line, and resume pumping. If the liquid being pumped comes out of the drain valve (B), repair the pump immediately to minimize internal damage to the pump. Additionally, the leak detector must be serviced. See Cleanup After a Leak.
WARNING
FIRE AND EXPLOSION HAZARD Never pump flammable fluids with polypropylene units. Such use could cause a fire or an explosion.
Cleanup After a Leak
If a spill occurs with tacky or viscous fluid, the fluid could solidify and interfere with the action of the moving parts. It is recommended that you check the following parts for cleaning or replacement any time the leak detector is activated (See Parts Drawing on page 13): D D D D D D Concentrator (3) Float (4) Push rod (5) Compression nut (6) Converter o-ring (12) Drain valve (B)
8
308702
Maintenance
For instructions on cleaning the inside of the leak detector and performing an actuator valve test, see Routine Cleaning and Test on page 10. For a function test that does not involve any disassembly, perform the following steps (See Parts Drawing on page 13): 1. [. . . ] (356 mm) widest dimension
TI14898a
14
308702
Notes
308702
15
Graco Standard Warranty
Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO HUSKY LEAK
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO HUSKY LEAK will begin.