User manual GRACO HV-35 63942-1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GRACO HV-35. We hope that this GRACO HV-35 user guide will be useful to you.

Lastmanuals help download the user guide GRACO HV-35.


Mode d'emploi GRACO HV-35
Download
Manual abstract: user guide GRACO HV-3563942-1

Detailed instructions for use are in the User's Guide.

[. . . ] HV-20/35 Series Proportioning Unit with AmpLok® Operating Manual 63942-1 November 24, 2004 Issue 2 GUSMER CORPORATION ® One Gusmer Drive Lakewood, New Jersey, USA 08701-8055 Toll Free 1-800-367-4767 (USA & Canada) Phone: (732) 370-9000 Fax: (732) 905-8968 Copyright 2004, GUSMER CORPORATION ® http://www. gusmer. com NOTICE: This manual contains important information about your GUSMER equipment. Read and retain for future reference. HV-20/35 Series Proportioning Unit NOTICE: The equipment described in this technical manual must only be operated or serviced by properly trained individuals, thoroughly familiar with the operating instructions and limitations of the equipment. For technical service, call your local distributor. Call: 1-800-FOR-GSMR (1-800-367-4767) for the name and telephone number of your local distributor. NOTICE: All statements, information and data given herein are believed to be accurate and reliable but are presented without guarantee, warranty or responsibility of any kind expressed or implied. [. . . ] Turn ON the green A- and R- heater switches. The lights within the switches will light up and the temperature controllers should begin to cycle toward their set points. If either set point needs to be changed, see page 23. IMPORTANT: Primary heating is almost instantaneous. Do not turn on the primary heaters until required for operation. Turn off the primary heaters during shutdowns exceeding one half-hour. WARNING: TO PREVENT EXCESSIVE PRESSURE BUILDUP IN THE HEATED HOSES, ALWAYS BRING THE HOSE UP TO THE SET POINT TEMPERATURE BEFORE TURNING ON THE HYDRAULIC SYSTEM. 24 63942-1, Issue 2 Operating Manual Operation 12. Turn ON the green hydraulic motor switch. The light within the switch will light up. One of the amber directional indicator lights will light and the proportioning pumps should move a short distance and pressurize. NOTE: The pump switch must be in the RETRACT or NORMAL position to adjust the hydraulic pressure. 14. Adjust the hydraulic pressure as required. Check the pressure of each proportioning pump. After setting the pump switch to NORMAL, monitor both pressure gauges. The resin and isocyanate pressures should be approximately equal and the pressures must remain fixed. Set the pump switch to RETRACT and observe the pressures again; they must remain fixed. If the pressure bleeds off on either stroke, see Proportioning System on page 30 before continuing. To equalize the upstroke pressure, turn the pressure reducing valve counterclockwise until it equals the chemical pressure reading on the down stroke. The proportioning unit is now ready for operation. Consult the spray gun operating manual and test spray as per the directions. Daily Shut-down Procedure 1. Trigger the spray gun off target until the isocyanate proportioning pump stops in the retracted position and the pressure of both pumps bleeds off to a point where the spray pattern begins to diminish. IMPORTANT: DO NOT bleed the pressure to zero, as some pressure is required to keep the packings operating normally and prevent seepage during shutdown. Turn OFF the green hydraulic motor switch. [. . . ] The lubrication system is now ready for operation. No priming is required. 6. 7. Hydraulic Drive System The hydraulic drive system should be checked annually for cleanliness and the fluid changed in accordance with the manufacturer's recommendation. Recommended hydraulic fluid: Mobil DTE 24 or 25. To service the hydraulic drive system, proceed as follows: 1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO HV-35

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO HV-35 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag