Detailed instructions for use are in the User's Guide.
[. . . ] Operation
309551H
Electric, Heated, Plural Component Proportioner
For spraying polyurethane foam and polyurea coatings. Not for use in explosive atmospheres.
See Models and Maximum Working Pressures on page 3.
Important Safety Instructions
Read all warnings and instructions in this manual. Save these instructions.
TI3764a-1
Graco Inc. Box 1441 Minneapolis, MN 55440-1441
Copyright 2003, Graco Inc. [. . . ] Be sure cables have slack when hose bends. Wrap cable and electrical connections with electrical tape.
Y
V
TI2727A
309551H
21
Setup
8. Close gun fluid manifold
valves A and B
9. Connect whip hose to
gun fluid manifold
Do not connect manifold to gun.
TI2417A TI2411A
10. If no leaks, wrap hose and electrical connections to protect from damage.
22
309551H
Setup
11. Set transformer wire
taps
WARNING 100 ft 50 ft 150 ft 200 ft 250 ft 300 ft
Read warnings, page 5.
Turn main power switch OFF
. Transformer tap
wire connections vary depending on length of heated hose. Verify that tap wire connections are correct.
50 ft
100 ft
150 ft
TI3470a
200 ft
Hose Length* ft (m) 60-85 (18. 3-25. 9) 110-135 (33. 5-41. 2) 160-185 (48. 8-56. 4) 210-235 (64. 1-71. 7) 260-285 (79. 3-86. 9) 310 (94. 6)
TI3469a
Tap Terminal Label (ft) 50 100 150 200 250 300
* Length includes heated fluid hose and whip hose. 8: Model E-30 and E-XP2 Transformer Wire Taps
. Hose Length* ft (m) 60-85 (18. 3-25. 9) 110-135 (33. 5-41. 2) 160-185 (48. 8-56. 4) 210-235 (64. 1-71. 7) Tap Terminal Label (ft) 50 100 150 200
* Length includes heated fluid hose and whip hose. 7: Model E-20 and E-XP1 Transformer Wire Taps
309551H
23
Setup
12. e.
Object being sprayed: follow your local code.
Solvent pails used when flushing: follow your local code. Use only metal pails, which are conductive, placed on a grounded surface. Do not place pail on a nonconductive surface, such as paper or cardboard, which interrupts grounding continuity.
Read warnings, page 5.
a. b.
Reactor: is grounded through power cord. See page 17.
Spray gun: connect whip hose ground wire to FTS, page 20. Do not disconnect wire or spray without whip hose.
f.
To maintain grounding continuity when flushing or relieving pressure, hold a metal part of spray gun firmly to the side of a grounded metal pail, then trigger gun.
c.
Fluid supply containers: follow your local code.
24
309551H
Setup
13. Supply wet-cups with
Throat Seal Liquid
WARNING
b.
Component B (Resin) Pump: Check felt washers in packing nut/wet-cup (R) daily. Keep saturated with Graco Throat Seal Liquid (TSL), Part No. 206995, to prevent material from hardening on displacement rod. Replace felt washers when worn or contaminated with hardened material.
Pump rod and connecting rod move during operation. Moving parts can cause serious injury such as pinching or amputation. [. . . ] 246033, 246034, 246035, 246036, 248658: 195-264 Vac, 50/60 Hz See TABLE 1, page 16. Model E-20: 6000 Watts Model E-30 and E-XP1: 10200 Watts Sound Power, per ISO 9614-2 Models E-XP2 and E-30 with 15. 3kW of heat: 15300 Watts Model E-20: 80 dB(A) at 2000 psi (14 MPa, 140 bar), 0. 5 gpm (1. 9 lpm) Model E-30: 93. 5 dB(A) at 1000 psi (7 MPa, 70 bar), 3. 0 gpm (11. 4 lpm) Model E-XP1: 80 dB(A) at 2000 psi (14 MPa, 140 bar), 0. 5 gpm (1. 9 lpm) Model E-XP2: 83. 5 dB(A) at 3000 psi (21 MPa, 210 bar), 1. 0 gpm (3. 8 lpm) Sound Pressure, 1 m from equipment Model E-20: 70. 2 dB(A) at 2000 psi (14 MPa, 140 bar), 0. 5 gpm (1. 9 lpm) Model E-30: 83. 6 dB(A) at 1000 psi (7 MPa, 70 bar), 3. 0 gpm (11. 4 lpm) Model E-XP1: 70. 2 dB(A) at 2000 psi (14 MPa, 140 bar), 0. 5 gpm (1. 9 lpm) Fluid Inlets Fluid Outlets Fluid Circulation Ports Weight Model E-XP2: 73. 6 dB(A) at 3000 psi (21 MPa, 210 bar), 1. 0 gpm (3. 8 lpm) 3/4 npt(f), with 3/4 npsm(f) union Component A (ISO): #8 JIC (3/4-16 unf), with #5 JIC adapter Component B (RES): #10 JIC (7/8-14 unf), with #6 JIC adapter 1/4 npsm(m), with plastic tubing Model E-20 and E-XP1: 342 lb (155 kg) Model E-30: 400 lb (181 kg) Wetted Parts Models E-XP2 and E-30 with 15. 3kW of heat: 438 lb (198 kg) Aluminum, stainless steel, carbon steel, brass, carbide, chrome, chemically resistant o-rings, PTFE, ultra-high molecular weight polyethylene
309551H
41
Graco Standard Warranty
Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations. [. . . ]