User manual GRACO VOLUMETRIC FLUID FLOW METER 308778M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GRACO VOLUMETRIC FLUID FLOW METER. We hope that this GRACO VOLUMETRIC FLUID FLOW METER user guide will be useful to you.

Lastmanuals help download the user guide GRACO VOLUMETRIC FLUID FLOW METER.


Mode d'emploi GRACO VOLUMETRIC FLUID FLOW METER
Download
Manual abstract: user guide GRACO VOLUMETRIC FLUID FLOW METER308778M

Detailed instructions for use are in the User's Guide.

[. . . ] Instructions-Parts Volumetric Fluid Flow Meter 308778M ENG For precise metering of plural component fluids or solvents (depending on model). For professional use only. See page 2 for model information, including maximum working pressure. Important Safety Instructions Read all warnings and instructions in this manual. S3000 Solvent Meter G3000 and G3000HR (Model 289813 with 90° Sensor Connector Shown) Recognized Component 9902471 Conforms to UL2279 Certified to CAN/CSA E79-0 CAN/CSA E79-11 TI11579a TI14674a II 1 G * 0359 EExia II A T3 ITS03ATEX21212X G250 and G250HR Intrinsically Safe for Hazardous Locations (Class I; Division 1; Group D) when used with an approved barrier only. * CE mark approvals only apply to meters used as part of Graco ProMix, ProMix 2KS, and PrecisionMix II Systems. TI13038a Models Contents Models . [. . . ] The G3000HR and G250HR meters flow volume range is 0. 01-0. 5 gal. /min. Shut off all electrical power to the fluid system. Follow the Pressure Relief Procedure for your fluid system dispensing device. The S3000 solvent meter flow volume range is 0. 01-0. 5 gpm (38-1900 cc/min). NOTICE The flow meter gears and bearings can be damaged if they rotate at too high a speed. To avoid high speed rotation, open the fluid valve gradually. Do not over-speed the meter with air or solvent. To prolong meter life, do not exceed the meter's maximum flow rate. Flow Meter Function This is a positive displacement, gear flow meter. The gear flow meter is highly accurate, even with low flow rates. The fluid flowing through the meter rotates the gears. The gear tooth is picked up by a sensor device, which produces an impulse for every gear tooth passing by. Checking the Meter Accuracy 1. To check the accuracy of the meter, turn your gun fan and atomizing air off, then trigger the fluid into a graduated cylinder; dispense at least 500 cc of fluid. Measure the volume of fluid in the beaker in cubic-centimeters (cc) and read the volume on the flow meter monitor. G3000 and G250: If the flow meter scale factor is not between 0. 112-0. 140 cc/pulse, follow the cleaning procedure on page 10, then recalibrate the flow meter. G3000HR and G250HR: If the flow meter scale factor is not between 0. 05-0. 07 cc/pulse, follow the cleaning procedure on page 10, then recalibrate the flow meter. Air purge is not recommended for any gear-type flow meter. Air purges do not provide the lubrication the meter gears require. Residue Build-up on the Meter Gears Residue build-up may cause the meter gears to bind or stop rotating, which decreases the meter accuracy and makes meter recalibration necessary. As more build-up occurs, recalibration is required more often. The frequency that your meter requires cleaning depends on the type of fluid being used. Excessive residue build-up usually means that you are using improper cleaning solvents and/or cleaning sequences or processes. · Check the meter routinely to develop the correct cleaning schedule. Use the proper cleaning solvent for the fluid being metered. · 308778M 9 Maintenance Cleaning or Servicing the Meter Chamber NOTICE Clean and service the meter at a clean workbench. [. . . ] With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco's written recommendations. This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GRACO VOLUMETRIC FLUID FLOW METER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GRACO VOLUMETRIC FLUID FLOW METER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag