Manual abstract: user guide GRASS VALLEY 8972PXDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] 78
8972PX Protection Switch
Key Features
· Two-input robust failure-proof changeover switch · Third alternate input, available for switching, non relay-protected · Supports HD-SDI, SD-SDI, and DVB ASI with auto-sensing capability · Will maintain signal path in the event of power failure or when the front card is removed · Eight outputs, including: -- One main relay-protected output with passive bypass path -- One electronic output follows main -- Three output pairs can be set to follow main or backup or can be switched to primary, secondary or alternate inputs · Line switching in driven switch mode (SD/HD-SDI syncronous input signals) · External control via GPI or Ethernet · Autonomous control by: -- Signal (carrier) loss detection -- Incorrect signal format -- EDH/CRC error (selectable threshold) -- DVB-ASI PID loss -- DVB-ASI packet loss · GeckoFlex dual-slot rear module · Asserting external control of the module automatically turns off autonomous control
The 8972PX is a full-time signal protection switch. [. . . ] The 8972PX fulfils the basic requirement of any protection system by not adding failure modes to the existing signal path. In the event of a power failure, or even if the front control module is completely removed, the Program Output signal will continue to pass from the previously selected input as a fail-safe relay path will latch the selected signal to the output. In driven mode it can be configured by GPI or Ethernet.
Alternate in Switchable Distributed Out Switchable Distributed Out GPI I/O Switchable Distributed Out Relay Protected Out Primary In
8900PX-DR
J1 J2
Switchable Distributed Out Switchable Distributed Out Switchable Distributed Out Main Distributed Out Secondary In
J3
J4
J5
J6
J7
J8
J9
J10
All parameters can be configured via the web browser interface and main parameters via the Newton Control Panel. NetConfig and NetCentral are supported respectively for remote configuration and product health monitoring. [. . . ] Asserting GPI control or other manual controls will disable autonomous control.
Primary Secondary Alternate GPI In
Equalization & Reclocking Equalization & Reclocking Equalization & Reclocking Input Signal Monitors
Autonomous Control
Main Protected Output
Bypass Relay Controls Latching Relay Control
REAR MODULE FRONT MODULE Main Distributed Output GPI Out
Main
Local Control
Switch Manager
Backup
GPI Out
Applications
· Select between primary, secondary, and alternate inputs paths · Switch to alternate input (i. e. , apology slide) when primary and secondary inputs are both failing
Configurable Output Pairs
Network Control GPI Control
Switchable Distributed Outputs
Network Interface
GPI In
Specifications
Supported Frame Types
GeckoFlex with 8900NET (Net Card) for configuration
Ordering Information Specifications
GPI
·Switchtoprimaryinput ·Switchtosecondaryinput ·Switchtoalternateinput This module can be mounted in a GeckoFlex frame but not in other 8900 series frames, including Gecko-A or Gecko-V frames and it requires two slots.
Power Rating
9. 0 Watts dual slot
Inputs
SD/HD-SDI or ASI: Three ·Input equalization: up to 125m HD/330m SD/ASI (when signal is not bypassed) ·Formatssupported:1080i@59. 94, 50, 720p @ 59. 94, 50, 480i @ 59. 94 576i @ 50 ·DVBASI:yes
GPO
Primary input status (failed/good) Secondary input status (failed/good) Alternate input status (failed/good) Switch state (primary/secondary/alternate)
8972PX
SD/HD/ASI protection switch, front and dual rear module set 8900PX-DBS D-connector backshell option, fitting with rear high density
Control and Monitoring
SNMP: Monitoring and switching control Web page configuration: Yes Local configuration: Switching control only Newton support: Yes NetConfig support: Yes
Outputs
Protected outputs: One Insertion loss on protected output when bypassed: Equivalent to less than 20m of Belden 1694A cable Return loss: <15 dB (when signal is not bypassed) Distributed outputs: Seven Return loss: <15 db
For detailed specifications, installation, and setup instructions see: www. grassvalley. com/docs/modular [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GRASS VALLEY 8972PX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.