If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual GTO PRO-SW 1000SERIES. We hope that this GTO PRO-SW 1000SERIES user guide will be useful to you.
Lastmanuals help download the user guide GTO PRO-SW 1000SERIES.
Manual abstract: user guide GTO PRO-SW 1000SERIES
Detailed instructions for use are in the User's Guide.
[. . . ] Installation Manual for the
¨
+
LIS
TED
75
Series
Automatic Gate Operator
for Vehicular Swing Gates
WARNING!
READ ALL INSTRUCTIONS CAREFULLY AND COMPLETELY before attempting to install and use this automatic gate operator. This gate operator produces a high level of force. Stay clear of the unit while it is operating and exercise caution at all times.
, INC.
3121 Hartsfield Road · Tallahassee, Florida, USA 32303 Telephone (800) 543-GATE or (850) 575-0176 · Fax (850) 575-8912 · www. gtoinc. com
© 2000 GTO, Inc.
RB918
rev-04/22/02
This product meets and exceeds the requirements of UL 325, the standard which regulates gate operator safety, as established and made effective March 1, 2000, by Underwriters Laboratories Inc.
GTO/PRO 1000 series automatic gate operators are intended for use with vehicular swing gates. These operators can be used in Class I, Class II and Class III applications. [. . . ] If your gate type matches this configuration, you DO NOT need to adjust the DIP switches; proceed to the Potentiometers section on the next page. NOTE: To change the DIP switch settings, you must turn the control box power switch OFF; move the switch; then turn the power back ON. Use a small screwdriver to move the switches. PULL/PUSH: Set to PULL for swing gates that pull-to-open [factory setting]; PUSH for swing gates that push-to-open (see Push to Open Installation on pages 30-31). NOTE: The direction a gate opens is determined by standing inside the property and facing toward the gate. SNGL/DUAL: Set to SNGL for a single gate leaf [factory setting]; DUAL for dual gate leaves. SEQ1: Controls the opening order of dual gate leaves. See Setting the Control Board for Dual Gate Installations on page 39 for more information. SEQ2: Controls the opening order of dual gate leaves. See Setting the Control Board for Dual Gate Installations on page 39 for more information. S
DIP switches
OBSTRUCT SENS.
PULL/PUSH SNGL/DUAL SEQ1 SEQ2
4
ON
1
2
3
MIN
MAX
LEARN
AUTOC 60 STATUS
LOSE
+
BATT
120 OFF
INERTIA
MAX MIN
UCT OBSTRS. SEN
MAX
USH PULL/P L UA SNGL/D EQ1 S SEQ2
MIN
LEARN
G RB
OPN EDG
CLS EDG
OPN EDG
CLS EDG
ORG BLU GRN
RED
BLK
ORG BLU GRN
GRN
ORG
BLU WHT
BLK
RED
SOLAR 18VAC + ~ ~
SECO FIRST
POWE R IN
ND O
TOR PERA
ALAR
M
ACCE
SSOR
Y
RCVR
OPER
ATOR
23
Potentiometers
The three (3) potentiometers on the control board operate like a volume control on a radio. They control the auto close timer, inertia, and obstruction sensitivity of the operator. Use a small slotted screwdriver to turn the arrow in the center of the potentiometer. Clockwise rotation increases the setting (MAX). Counterclockwise rotation decreases the setting (MIN). AUTO CLOSE (auto close timer): Determines how long the gate will remain open before it automatically closes. INERTIA: Fine tunes obstruction sensitivity in the opening and closing modes. INERTIA allows the operator to attempt to push an obstruction clear of the gate path. When INERTIA is set to MIN the operator will obstruct quickly (i. e, . will attempt to push an obstruction briefly); when set to MAX, the operator will obstruct slowly (will attempt to push against an obstruct for a longer period). (obstruction sensitivity): Determines the amount of force exerted by the gate on an obstruction before the operator stops and reverses. [. . . ] The kit comes with the battery and wiring harness for easy installation. Battery life 3 to 5 years.
GTO NEMA Box (FM317)
GTO's NEMA 4X rated weatherproof box is large enough (14" W x 6" D x 16" H) to accommodate all add-on items necessary for custom gate operator installations. It is made of fire retardant ABS plastic and comes with a heavy duty 14 gauge steel backing plate for mounting accessories. The unique, lockable cover (use the Master® Pin lock RB975 for added security) can be completely removed for easier access during installation and service. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE GTO PRO-SW 1000SERIES Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual GTO PRO-SW 1000SERIES will begin.