Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAFLER GX 2300. We hope that this HAFLER GX 2300 user guide will be useful to you.
Lastmanuals help download the user guide HAFLER GX 2300.
Detailed instructions for use are in the User's Guide.
[. . . ] Table of Contents
DECLARATION OF CONFORMITY . . 9 What else distinguishes these amplifiers?. 21 SERVICE POLICY AND LIMITED WARRANTY . provide the same three wire grounded connection. [. . . ] This thermally-tracking fan speed circuit keeps fan noise to a minimum when power demands are low. Typically the fans will be turning slowly even at idle conditions - although abnormally low room temperatures may allow the fans to turn off completely. The fan control circuit also has a turn-on blast feature that runs the fans at full speed for a few seconds every time the amplifier is turned on. This serves the dual function of cleaning out the air tunnel, and providing a simple means to check the fans for proper operation. If you suspect that the fans are not operating correctly, try turning the amplifier off, then listening or feeling for the turn-on blast when the amplifier is turned back on. Thermal Standby - If excessive heatsink temperature is detected, the individual amplifier channel will go into thermal standby mode. The amplifier will be turned off, and the THERMAL LED illuminates until heatsink temperatures return to normal. At that time the amplifier automatically turns back on, and continues operating normally. NOMAD protection - The amplifier output MOSFETs are protected from excessive power dissipation by NOMAD protection circuitry. NOMAD (Non-Multiplying Advance Decision) limits the power when it measures signal voltage and current conditions that will exceed the pre-determined power limit of the MOSFETs. This instantaneous power calculation is performed on each output MOSFET, causing the amplifier to automatically limit power when needed. In this way, a speaker load with an impedance "dip" over a particular frequency range will only activate the NOMAD protection when sufficient audio is present at that same frequency range, but continue operating normally otherwise. Short protection - The NOMAD protection circuit also protects against shorts, and will instantly limit the output power if speaker wires are shorted together. Normal operation will continue immediately after the short is removed. Power Supply Current Limiting protection- The switching power supply will protect itself from excessive power dissipation by continuously monitoring currents in the switching MOSFETs. The Current Limiting circuit measures the currents in the switching MOSFETs and will instantly limit them to a safe level. Soft turn-on/fast turn-off - Speaker loads are protected from turn-on/turn-off transients by a circuit that monitors the power supply, and controls the amplifier when power on/off events are detected. At turn-on, this circuit waits for power supply voltages to settle, then sends a turn-on ramp signal to slowly turn the amplifier on. At turn-off, this circuit acts quickly to turn off the amplifier before power supply capacitors discharge, and voltages collapse into the output signal - causing speaker "pops".
10
Design Features
-18-15 -12 -21 -9 -24 -6 -27 -3 -32 -38
OFF
70V 100v 4 8 2
CH A
signal
Channel A
0dB
protect
Load
Power
Stereo Mono 70V 100V
-18-15 -12 -21 -9 -24 -6 -27 -3 -32 -38
OFF
2300
clip
thermal
70V 100v 4 8 2
CH B
Channel b
0dB
1
9
2
3 12
HP
4
180° 0°
6 0"6"12"18"24"30"ON
7
8
A Division of Rockford Corp. Tempe, AZ 85281
Crossover LP CD EQ +0 2
+10 dB Full
Phase choose
one only
Audio GND Chassis Float
Delay must
300W 2 8
--
For 70V, 100V, or Mono · Use CH B input · Load across RED terminals · Set load switches to one half load impedance Attention: Utiliser un fusible de rechange de même type. CAUTION: For continued protection from risk of fire, replace only with same type and rating of fuse.
®
G X 2 3 0 0 Made in the U. S. A.
300 W Stereo, 2 8 600W Mono, 70V, 100V
Freq
CH A IN
500Hz 800Hz
BIAMP STEREO Crossover LP CD EQ Freq
Full +0 2 6 HP
180° 0°
Phase
-- +
Delay must choose one only 600W
+ +
300W 2 8
+10 dB
500Hz 800Hz
0"6"12"18"24"30"-
--
CH B IN (Mono)
4 16 ON Mono, 70V, 100V Class 2 wiring
250V T7A
250W 115V~ 50-60Hz
5
15
6
10
11
13
14
16
1. Recessed Front Panel - Prevents switches and controls from accidentally being adjusted or broken. [. . . ] CH B input sensitivity controls 70V mono output level. Amplifier will clip at 70Vrms level.
20
100V MONO MODE (GX2300/GX2600)
1. Connect signal from source to CH B input. Stereo/Biamp switch not active (Stereo/Mono switch overrides this switch when in mono/70V/100V mode). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAFLER GX 2300
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAFLER GX 2300 will begin.