[. . . ] SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
Contents
AS18GS1ERA AS24GS1ERA
PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLAION MAINTENANCE CAUTIONS TROUBLE SHOOTING 2 3 5 9 10 11
Please read this operation manual before using the air conditioner. Keep this operation manual for future reference.
NO. 0010535426
Parts and Functions
Indoor Unit
1 8
11 10 9 8
Remote controller
12
2
ON/OFF
13 14 15 16 17
18
9. Mode display
Operation mode Remote controller
AUTO COOL DRY FAN HEAT
7
6
FAN
5
3 4 5 1 2 3 4 5 6 7
4 3 2
MODE
SWING
POWER/SOFT
19 20 21 22
TIMER
CLOCK
LIGHT
SET
SLEEP
Inlet Inlet grille Outlet Vertical blade
(adjust left and right air flow)
6 7 8
Display board Emergency Switch Air Purifying Filter
(inside)
23 24
1
LOCK
RESET
12. HOUR / POWER/SOFT button Used to set clock and timer setting. [. . . ] In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened.
Accessory Parts
Remote controller (1) Drain hose (1)
R-03 dry battery (2) Mounting plate (1)
Plastic cap (4) Ø4X25 Screw (4) Air purifying filter(Optional) (1)
Selection of Pipe
FOR 18K FOR 24K
Drawing for the installation of indoor units
The models adopt HFC free refrigerant R410A
Attention must be paid to the rising up of drain hose
more than 15 cm
Arrangement of piping directions Rear left
more than 10cm
Left
Rear right Right Below
more than 10cm
The distance between the indoor unit and the floor should be more than 2m. Please be subject to the actual product purchased, the above picture is just for your reference.
6
Indoor Unit Installation
Fitting of the Mounting Plate and Positioning of the wall Hole When the mounting plate is first fixed
1. Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be fixed against the wall, then temporarily fasten the plate with one steel nail. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. Find the wall hole location A using a measuring tape
1. Insert the drain hose into the dent of heat insulation materials of indoor unit. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Indoor/outdoor electric cable Heat insulation material
Lid for right piping Lid for under piping pipe Fix with adhesive tape
Piping Pipe supporting plate
Lid for left piping Drain hose
B= Ø 70mm
Indoor/outdoor electric cable and drain hose must be bound with efrigerant piping by protecting tape.
[ Other direction piping ]
A=145mm
Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to theposition of wall hole. When bending, be careful not to crash pipes. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially.
B= 70mm
30mm
Fixing the indoor unit body
A=150mm
35mm
When the mounting plate is fixed side bar and lintel
Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting bar. Refer to the previous article, " When the mounting plate is first fixed ", for the position of wall hole.
Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly. mounting plate
Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 70 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation
Wall hole
Unloading of indoor unit body
When you unload the indoor unit, please use your hand to arise the body to leave agraffe, then lift the bottom of the body outward slightly and lift the unit aslant until it leaves the mounting plate.
Ø70mm
Indoor side
Outdoor side Thickness of wall
(Section of wall hole)
G Piping hole pipe
agraffe
mounting plate
Installation of the Indoor Unit Drawing of pipe
Connecting the indoor/outdoor Electric Cable Removing the wiring cover
Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws.
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
7
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop.
Correct
Incorrect
Lean
Damage of flare
Crack
Partial
Too outside
On Drainage
Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. [. . . ] During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system. ) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes.
During COOL or DRY operation, indoor unit may blow out mist. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER AS24GS1ERA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.