[. . . ] FLOOR UNIT OPERATION MANUAL
HFU-09HA03(B)/R1 HFU-12HA03(B)/R1 HFU-09H03/R2(DB) HFU-12H03/R2(DB) HFU-18H03/R2(DB)
Please read this operation manual before using the air conditioner.
No. 0010557172
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled . Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. [. . . ] Operation mode will be displayed on LCD 2. Timer mode selection Press TMIER button to change TIMER mode. Every time' the button pressed, display changes as follows:
Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash. Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidly. 4. Confirming your setting After setting correct time, press SET button to confirm " "or" "on the remote controller stops flashing. Time displayed: Unit starts or stops at x hour x min. 5. Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one.
16
Operation
TIMER On-Off Operation
Set clock correctly before starting TIMER operation. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Remote Controller
Then select your desired TIMER mode (TIMER ON - OFF). Every time the button is pressed, time setting increases 1 min, if kept depressed, it will increase rapidly. Every time the button is pressed, time setting decreases 1 min, if kept depressed, it will decrease rapidlly. 4. Timer confirming for TIMER ON After setting correct time, press TIMER button to confirm " " on the remote controller stops flashing. Time displayed: Unit starts or stops at x hour x min. 5. Time setting for TIMER OFF Just press HOUR button , follow the same procedure in "Time setting for TIMER ON" 6. Time confirming for TIMER OFF After time setting, press SET button to confirm. " " on the remote controller stops blinking. Time displayed:Unit stops at x hour x min. To cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. [. . . ] Vacuumize first, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate.
Valve rod cap
Valve rod cap
3-way valve 12. 7mm(1/2") 2-way valve 6. 35mm(1/4")
2-way valve 6. 35mm(1/4") 3-way valve 9. 52mm(3/8")
HFU-12HA03(B)/R1
HFU-09HA03(B)/R1
28
Installation Manual of Room Air Conditioner
Note: When additional refrigerant is necessary, first purge air out of connecting pipe by external gas, then drive out the excessive refrigerant by purging method. . Brand new unit is charged 80g more refrigerant than spec. This is only for first installation to purge air in the indoor unit and connecting pipe. When piping is longer than 5m, change additional refrigerant specified in this list. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HFU-18H03/R2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.