Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HPU-123C01. We hope that this HAIER HPU-123C01 user guide will be useful to you.
Lastmanuals help download the user guide HAIER HPU-123C01.
Detailed instructions for use are in the User's Guide.
[. . . ] Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly, operation and maintenance of the air conditioner. The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction. Damaged air conditioners are not to be put into operation. [. . . ] LOCK
Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears.
6. HOUR button
Used to set clock and timer setting.
NOTE: 1. Cooling only unit do not have functions and displays related with heating.
7
Parts and Functions
Clock Set
When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: 1. Press CLOCK button, "AM" or "PM" flashes. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working.
Remote controller's operation
When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw or knock the remoter controller. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.
Loading of the battery
Load the batteries as illustrated right 2 R-03 (7#) batteries
Remove the battery cover:
Slightly press" as illustrated. 4
Pos. 1 Pos. 2 Pos. 3
(Auto swing)
Fig. 3
2. Up and down air flow direction
For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN: remote controller: Vertical flap: AUTO: remote controller: Vertical flap:
Pos. 1 Pos. 1 Pos. 2 Pos. 2 Pos. 3 Pos. 3 Pos. 4 Pos. 4 Pos. 6 Pos. 5
Fig. 3
Pos. 1 Pos. 1
Pos. 2 Pos. 2
Pos. 3 Pos. 3
Pos. 4 Pos. 4
Pos. 5 Pos. 5
Pos. 6 Pos. 6
Fig. 4
The vertical flap will swing according to the above positions NOTE: When we stop the air conditioner with remote controller or controlling plate, the flap will close automatically. If we cut off the power directly, the flap could not close itself. So you should shut off the machine with remote controller or controlling plate, You MUST NOT cut off the power when the machine is running.
3. Left and right air flow direction
For each press of remote controller: Horizontal louvers: button, remote controller displays as follows :
Pos. 1 Pos. 1 Pos. 2 Pos. 2 Pos. 3 Pos. 3 Pos. 4 Pos. 4 Pos. 5 Pos. 5 Pos. 6 Pos. 6 Pos. 7 Pos. 7 Pos. 8 Pos. 8
Fig. 5
The horizontal louvers will swing according to the above positions.
14
Operation
Display board
TEMP
Sleep Operation
SLEEP
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. In COOL, DRY mode 1 hours after SLEEP mode starts, temp. The unit will run for further 6 hours then stops. setting so that room temperature won't be too Iow for your sleep.
SLEEP operation starts
SLEEP operation stops Approx. 6hrs Rises 1OC
1 hr
1 hr
Rises 1OC
Temp. setting
Unit stop
In COOL, DRY mode
Remote Controller
2. [. . . ] If you install the peripheral equipment according to the manual of the matching remote control detector, it can realize the computer management or remote monitoring of the conditioner. Please refer to the manual of the "Conditioner remote control detector " for the details.
Trouble display
If the conditioner has trouble, the control panel will display "E ". Please switch off the power supply, and restart the machine. If it still displays the error code, please switch off the power supply, and contact the local after-sales technicians for maintenance.
Power failure resume (please set and apply as necessary)
With setting of power failure resume, if sudden power failure occurs, the unit will resume original operation when power is supplied again.
Setting method:
With ON of remote controller(except TIMER and FAN), repeatedly press SLEEP button 10 times in 5 seconds, after 4 Beep from the buzzer, the unit comes into power failure resume mode.
To cancel:
Press SLEEP button continuously 10 times in 5 seconds, the buzzer sounds Beep twice and power failure resume function is canceled.
Note:
When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFF to turn off the unit when power resumes.
19
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Do not block the air inlet or outlet
Proper temperature
Close doors and windows during operation
Use the timer effectively
During cooling operation prevent the penetration of direct sunlight with curtain or blind
If the unit is not to be used for a long time, turn off the power supply main switch.
Use the louvers effectively
SET HUMIDITY TEMP.
HEALTH TIMER SLEEP
ON/OFF
FAN
TEMP +
TEMP -
OFF
20
Maintenance
For Smart Use of The Air Conditioner
WARNING
Before maintenance, be sure to turn off the system and the circuit breaker.
Remote Controller
Indoor Body
Do not use water, wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth.
Wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping. then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline, benzine, thinner or cleanser may damage the coating of the unit.
Hot water over 40 C(104 F) may cause discoloring or deformation.
O
O
Air Filter cleaning
Press the clasp on the top of the grill and pull the grill out, and then the filter will be taken out along a gradient way.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HPU-123C01
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HPU-123C01 will begin.