User manual HAIER HPU-18CA03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HPU-18CA03. We hope that this HAIER HPU-18CA03 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HPU-18CA03.


Mode d'emploi HAIER HPU-18CA03
Download
Manual abstract: user guide HAIER HPU-18CA03

Detailed instructions for use are in the User's Guide.

[. . . ] Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal. Safety Instructions and Warnings Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very important observations relating to the assembly , operation and maintenance of the air conditioner. The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction. [. . . ] Press CLOCK button, "AM" or "PM" flashes. Each press will increase or decrease 1 min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM" or "PM" stop flashing, while clock starts working. E. HEAT Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw or knock the remoter controller. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter. Loading of the battery Load the batteries as illustrated right 2 R-03 (7#) batteries Remove the battery cover: Slightly press" as illustrated. "area and push down the cover Load the battery: Be sure that the loading is in line with the "+" / "-". request as illustrated on the bottom of the case. Put on the cover again. Confirmation indicator: After pressing power ON/OFF, if no display, reload the batteries. Note: Full display or unclear display during operation indicates the batteries have been used up. Used two new same-typed batteries when loading. In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode. E. HEAT 4. 5. Set the wind speed change when sleeping If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. If it is low wind, no change. 14 TIMER 10 10 15 Operation TIMER On-Off Operation Control panel Set clock correctly before starting TIMER operation. After unit starts, select your desired operation mode. Operation mode will be displayed on LCD. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: RemoteController E. HEAT Then select your desired TIMER mode (TIMER ON or TIMER OFF). Every time the button is pressed, time setting increases 10min, if kept depressed, it will increases rapidly. Every time the button is pressed, time setting decreases 10min, if kept depressed, it will decreases rapidlly. Time confirming for TIMER ON After setting correct time, press TIMER button to confirm. " " on the remote controller stops flashing. [. . . ] (4) Open 2-way and 3-way valves using specified torque. (5) Tighten the caps on the valves with specified torque. Pipe Diameter ( ) Fastening Torque 18N. m 50N. m 42N. m 60N. m 2-way valve 3-way valve 3-way valve 2-way valve Liquid side Gas side Liquid side Gas side Forced fastening without careful centering may damage the threads and cause a leakage of gas. Liquid Side 6. 35mm(1/4") Gas Side 15. 88mm(1/2") Liquid Side 9. 52mm(3/8") Gas Side 15. 88mm(5/ 8") Outdoor unit Max. Length: Oil trap for 18K 24K: A=20m Outdoor unit A Indoor unit Max. Elevation: for 18K 24K: 10m CAUTION In case more than 5m Oil trap shoud be installed every 5~7m Indoor unit no more gas if the length of connecting pipe is less than 20m(18K 24K). The height difference between any two indoor or outdoor units can not be more than 10m(18K 24K). Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according to the following list. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HPU-18CA03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HPU-18CA03 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag