User manual HAIER HSM-12RUC03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSM-12RUC03-R2. We hope that this HAIER HSM-12RUC03-R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSM-12RUC03-R2.


Mode d'emploi HAIER HSM-12RUC03-R2
Download
Manual abstract: user guide HAIER HSM-12RUC03-R2

Detailed instructions for use are in the User's Guide.

[. . . ] If the button is kept pressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working. MODE HEALTH AIRFLOW is in line with the " + "/"-"; Load the battery, then put on the cover again. SWING SLEEP FRESH SWING CLOCK TIME + SET POWER /SOFT Note: The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the recei ver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter. Full display or unclear display during operation indicates the batteries have been used up. [. . . ] Note: when the function is running, don't open the inlet grille. In HEAT mode 3. In AUTO mode The unit operaters in corresponding sleep mode adapted to the automatically selected operation mode. 4 Operation Timer On/Off On-Off Operation Set clock correctly before starting TIMER operation. 1. After unit starts, select your desired operation mode. 2. Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS CE All the products are in conformity with the following European provision: - Low Voltage Directive 73/23/EEC - Low Voltage Directive 2006/95/EC -Electomagnetic CompatibilitY 89/336/EEC -Electomagnetic CompatibilitY 2004/108/EC ROHS The products are fulfilled with the requirements in the directive 2002/95/EEC of the European parliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment (EU RoHS Directive) Then select your desired TIMER mode (TIMER ON or TIMER OFF or TIMER ON-OFF). " "or " "will flash. 3. Press TIME+ /TIME- button to set time. 4. After setting correct time, press SET button to confirm " "or" " on the remote controller stops flashing. 5. Cancel TIMER mode Just press TIMER button several times until TIMER mode disappears. Hints: After replacing batteries or a power failure happens, time setting should be reset. Remote controller possesses memory function, when use TIMER mode next time, just press SET button after mode selecting if time setting is the same as previous one. According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved. WEEE In accordance with the directive 2002/96/CE of the European parliament, herewith we inform the consumer about the disposal requirements of the electrical and electronic products. DISPOSAL REQUIREMENTS: Your air conditioning product is marked with this symbol. This means that electrical and electronic products shall not be mixed with unsorted household waste. The filled out label must be adhered in the proximity of the product charging port (e. g. onto the inside of the stop value cover). A contains fluorinated greenhouse gases covered by the Kyoto Protocol B factory refrigerant charge of the product: see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging 5 Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Proper temperature Do not block the air inlet or outlet Remote Controller Indoor Body Do not usewater, wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth. wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping, then wipe off the detergent completely. Do not use the following for cleaning Close doors and windows during operation Use the timer effectively Gasoline, benzine, thinner or cleanser may damage the coating of the unit. Hot water over 40 O C(104O F) may cause discoloring or deformation. During cooling operation prevent the penetration of direct sunlight with curtain or blind Air Filter cleaning Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. If the unit is not to be used for a long time, turn off the power supply main switch. Use the louvers effectively Clean the filter. Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects. OFF Once every two weeks Close the inlet grille. Replacement of Air Purifying Filter 1. Open the lnlet Grille Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit. 4. Attach the standard air filter (Necessary installation) ATTENTION: The white side of the photocatalyst air purifying filter face outside, and the black side face the unit The green side of the bacteria-killing medium air purifying filter face outside, and the white side face the unit. 2. Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 5. Close the Inlet Grille Close the Grille surely Detach old Air Purifying Filter NOTE: The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The bacteria-killing medium air purifying filter will be used for a long time, no need for replacement. But in the period of using them , you should remove the dust frequently by using vacuum cleaner or flaping them lightly, otherwise , its performance will be affected. Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it, or its ability of sterilization will be reduced. 3. Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames. 6 Cautions WARNING Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. WARNING When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. [. . . ] A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 11 . The power plug and connecting cable must have acquired the local attestation. 12. In order to protect the units, please turn off the A/C first, and at least 30 seconds later, cutting off the power. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSM-12RUC03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSM-12RUC03-R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag