User manual HAIER HSU-07CM03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-07CM03. We hope that this HAIER HSU-07CM03 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-07CM03.


Mode d'emploi HAIER HSU-07CM03
Download
Manual abstract: user guide HAIER HSU-07CM03

Detailed instructions for use are in the User's Guide.

[. . . ] The power source is the same as the corresponding name plate. Install an exclusive branch circuit of the power. A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it. Selection of pipe To this unit, both liquid and gas pipes shall be insulated as they become Iow temperature in operation. [. . . ] Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. A breaker should be incorporated into fixed wiring. For installation in other places, use a circuit breaker as far as possible. 2. Cutting and Flaring Work of Piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. A Liquid side Pipe diameter( 6. 35mm(1/4") 9. 52mm(3/8") 12. 7mm(1/2") ) Size A(mm) 0. 8~1. 5 1. 0~1. 8 1. 2~2. 0 Flare tooling die Gas side Gas side Correct Incorrect Lean Damage of flare Crack Partial Too outside 3. On Drainage Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below. Less than 5cm It becomes high midway. The gap with the ground is too small There is the bad smell from a ditch Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out surely to outdoor. In case that the attached drain hose is in a room, please apply heat insulation to it without fail. Check for Installation and Test Run Put check mark in boxes Check Items for Test Run Please kindly explain to our customers how to operate through the instruction manual. Is drainage securely carried out?Is power source voltage abided by the code?Are cooling and heating (when in heat pump) performed normally?Is the operation of room temperature regulator normal? Gas leak from pipe connecting?Are the connecting wirings of indoor and outdoor firmly inserted to the terminal block?Is the connecting wiring of indoor and outdoor firmly fixed? 8 Haier Industrial Park, No. 1 Haier Road, Qingdao, P. R. China IT CONFORMITÀ ALLE DIRETTIVE EUROPEE PER I MODELLI: CE Tutti i prodotti sono conformi alle seguenti normative europee: - Direttiva 73/23/EEC Basso Voltaggio - Direttiva 2006/95/EC Basso Voltaggio - Direttiva 89/336/EEC Compatibilità elettromagnetica - Direttiva 2004/108/EC Compatibilità elettromagnetica ROHS Il prodotto è conforme alla normativa 2002/95/EEC sulla restrizione d'uso di sostanze inquinanti negli apparecchi elettrici ed elettronici. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery. [. . . ] A B C D E F contiene gas fluorurati ad effetto serra inclusi nel protocollo di Kyoto carica di refrigerante di fabbrica del prodotto: vedi targhetta con il nome dell'unità quantità di refrigerante aggiuntiva nel campo carica di refrigerante totale unità esterna cilindro del refrigerante e collettore di carica Questo prodotto contiene gas fluorurati ad effetto serra inclusi nel Protocollo di Kyoto. Non liberare tali gas nell'atmosfera. Tipo di refrigerante: R410A Valore GWP*: 1975 *GWP = potenziale di riscaldamento globale Compilare con inchiostro indelebile, ·1 la carica di refrigerante di fabbrica del prodotto ·2 la quantità di refrigerante aggiuntiva nel campo e · 1+2 la carica di refrigerante totale sull'etichetta di carica del refrigerante fornita con il prodotto EN IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED The filled out label must be adhered in the proximity of the product charging port (e. g. onto the inside of the stop valve cover). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-07CM03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-07CM03 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag