User manual HAIER HSU-07HC03/R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-07HC03/R2. We hope that this HAIER HSU-07HC03/R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-07HC03/R2.


Mode d'emploi HAIER HSU-07HC03/R2
Download
Manual abstract: user guide HAIER HSU-07HC03/R2

Detailed instructions for use are in the User's Guide.

[. . . ] SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-07HC03/R2 HSU-09HC03/R2 HSU-12HC03/R2 Please read this operation manual before using the air conditioner. No. 0010551787 Contents Cautions Parts and functions Operation Maintenance Trouble shooting 1 2-4 5-12 13-15 16 Cautions The machine is adaptive in following situation 1. Applicable ambient temperature range: Indoor Cooling Outdoor Indoor Heating Outdoor Maximum: D. B / W. B Minimum: D. B / W. B Maximum: D. B Minimum: D. B Maximum: D. B Minimum: D. B Maximum: D. B / W. B Minimum: D. B / W. B 32 C/23 C o o 18 C/14 C o o 43 C/26 C o 18 C o 27 C o 15 C o o 24 C/18 C o o -7 C/-8 C o o 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F Cooling Heating 3G1. 0mm2 3G1. 0mm2+2x1. 0(0. 75)mm2 3. [. . . ] (Not Timer setting) Power indicator on indoor unit lights up. Use COOL in summer. Use HEAT in winter Use DRY in spring, autumn and in damp climate. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: ON/OFF TEMP AUTO COOL DRY HEAT FAN 6 1 3 3 SET MODE Unit will run in operation mode displayed on LCD. Stop display at your desired mode. 2 (3) Select temp. o Every time the button is pressed, temp. setting increases 1 C o Every time the button is pressed, temp. setting decreases 1 C Unit will start running to reach the temp. setting on LCD. FAN TIMER 4 SWING CLOCK 5 SLEEP (4) Fan speed selection Press FAN button. For each press, fan speed changes as follows: LOCK RESET AUTO LO MED HI COOL operation starts when room temp. setting. Ultra-low air flow Unit runs at the speed displayed on LCD. setting, unit will run intermittently at LO speed regardless of FAN setting. o Temp. setting, unit will run in mild DRY mode. Hints On cooling only unit, heating mode is not available. Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status. 7 Operation (5) Air flow direction adjustment After operation mode is selected, vertical flap will open automatically according to the mode. COOL About 10 o HEAT About 60o Up and down (Use remote controller) Left and right air flow adjustment Press SWING button, vertical flap will move within (manual) the range shown in the Fig. Press SWING button stop it at a fixed position. Move the horizontal blade by a knob on air conditioner to adjust left and right direction referring to Fig. About 10o COOL About 45o HEAT About 60o Cautions: It is advisable not to keep vertical flap at downward position for a long time in COOL or DRY mode, otherwise, condensate water might occur. Cautions: When humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right. (6) Unit stop Press ON/OFF button. Vertical flap closes automatically. Cautions: Unit won't restart until 3 minutes have elapsed, due to system protection. HEAT mode is not available on cooling only unit. Hints As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEAT mode, adjusting air flow downward will be much more helpful for a better air circulation. Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference of 3-5 C will remove your fatigue. [. . . ] The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. The solarization time will last no less than 8 hours under the state of abundant sun. The bacteria-killing medium air purifying filter is available for a long time and neednít to be changed. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-07HC03/R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-07HC03/R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag