User manual HAIER HSU-07HEK03 HSU-09HEK03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-07HEK03 HSU-09HEK03. We hope that this HAIER HSU-07HEK03 HSU-09HEK03 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-07HEK03 HSU-09HEK03.


Mode d'emploi HAIER HSU-07HEK03 HSU-09HEK03
Download

You may also download the following manuals related to this product:

   HAIER HSU-07HEK03 HSU-09HEK03 annexe 1 (1786 ko)

Manual abstract: user guide HAIER HSU-07HEK03 HSU-09HEK03

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual. Necessary Tools for Installation 1. Driver 2. Hacksaw 3. Hole core drill 4. Spanner(17, 19 and 26mm) 5. Torque wrench(17mm, 22mm, 26mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap-and-water solution 11. Measuring tape 12. Reamer Drawing for the installation of indoor and outdoor units Accessory parts 1 2 3 Mounting plate Remote controller 1 2 1 1 6 4 1 1 4 1 1 Optional parts for piping Mark A B C D E F G Parts name Non-adhesive tape Adhesive tape Saddle(L. S) with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover mo re tha n R-03 dry battery 10c m 4 5 6 7 8 9 10 11 more than 5cm No. Accessory parts Number of articles Drain hose 4X50 Steel nail, cement 4X25 Screw Plastic cap mo re tha n1 0cm Attention must be paid to the rising up of drain hose A Drain-elbow Cover Cushion Arrangement of piping directions Rear left Left Rear right Below Right mo re tha n1 0c m C re t mo m 10c han Pipe supporting plate Connecting cable Note:Cooling only units don't have Drain-elbow E D more than 60cm mor e than 15c m The marks from A to G in the figure are the parts numbers. [. . . ] After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. The wiring method should be in line with the local wiring standard. [. . . ] Length: for 5K 7K 9K 10K: A=7m for 12K 13K: A=10m for 18K 22K 24K: A=20m CAUTION In case more than 5 metresoil trap should be installed every 5~7m. C 4 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-07HEK03 HSU-09HEK03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-07HEK03 HSU-09HEK03 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag