[. . . ] Air Conditioner
Edition:2006/02/11
OPERRATION
Air Conditioner
Edition:2006/02/11
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled . Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. [. . . ] If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
POWER/SOFT
FRESH
16
Air Conditioner
Edition:2006/02/11
Operation
HEALTH operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts. Health function includes health anion function, UV light degerming function.
2. Health anion function
Press HEALTH button. Air conditioner starts health anion function operation. For twice press, disappears, the operation stops.
3. Change-for-fresh-air function(optional)
Press FRESH button , " "displayed on the remote controller and the change-for-fresh-air function operation begins. For twice press , the display " "disappears and the change-for-fresh-air function operation is canceled
When indoor fan motor is running, it has healthy process function. About Auto Operation Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature.
18
Air Conditioner
Edition:2006/02/11
Operation
Cool Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select COOL operation
3. Select temp. setting
FRESH
POWER/SOFT
Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5. Unit stop
Press ON/OFF button, the unit stops.
19
Air Conditioner
Edition:2006/02/11
Operation
Dry Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select DRY operation
3. Select temp. setting
FRESH
POWER/SOFT
Press TEMP. button Every time the button is pressed, temp. setting increase 1oC, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting decrease 1oC, if kept depressed, it will decrease rapidly Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
COOL operation starts when room temp. is higher than temp. setting. Temp. setting+2oC Temp. setting
Ultra-low air flow
Air conditioner is running under displayed fan speed. In DRY mode, when room temperature becomes lower than temp. setting+2oC, unit will run intermittently at LOW speed regardless of FAN setting.
5. Unit stop
On reaching temp. setting +2oC unit will run in mild DRY mode.
Press ON/OFF button, the unit stops.
20
Air Conditioner
Edition:2006/02/11
Operation
Fan Operation
1. Unit start
Press ON/OFF on the remote controller, unit starts.
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select FAN operation
3. Fan speed selection
FRESH
Press FAN button. For each press, fan speed changes as follows: Remote controller:
POWER/SOFT
LOW
MED
HI
4. Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. [. . . ] 2. In heating, it is better to select the mode. 3. In cooling, it is better to select the mode. 4. In cooling and dry, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille . 5. Select the appropriate fan direction according to the actual conditions.
28
Air Conditioner
Edition:2006/02/11
Operation
Emergency and Test Operation
Emergency operation:
Use this operation only when the remote controller is defective or lost. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09H03/U
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.