User manual HAIER HSU-09HEA13-B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09HEA13-B. We hope that this HAIER HSU-09HEA13-B user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-09HEA13-B.


Mode d'emploi HAIER HSU-09HEA13-B
Download

You may also download the following manuals related to this product:

   HAIER HSU-09HEA13-B annexe 1 (601 ko)

Manual abstract: user guide HAIER HSU-09HEA13-B

Detailed instructions for use are in the User's Guide.

[. . . ] Operation mode display O Operation mode AUT COOLDRY HEAT FAN Remote controller 22. RESET Used to select TIMER ON, TIMER OFF, TIMER ON-OFF Used to set correct time Display board Used to reset the controller back to normal condition. Used to operate the healthy function 2. [. . . ] After another 1 hours, temp decrease by 2 O C further. The unit will run for further 3 hours then stops. setting so that room temperature won't be too high for your sleep. 2. In HEAT mode LOCK RESET Temp. setting 1 hr 1 hr O Unit stop Decreases 2 C O Decreases 2 C 3 hrs Rises 1 C 3 hrs SLEEP SLEEP operation stops operation starts In HEAT mode O Operation Mode 1. In COOL, DRY mode 1 hours after SLEEP mode starts, temp. The unit will run for further 6 hours then stops Temp. setting so that room temperature won't be too Iow for your sleep. SLEEP operation stops SLEEP operation starts Approx. 6hrs 3. In AUTO mode The unit operates in corresponding sleep mode corresponding sleep mode adapted to the automatically selected operation mode. In FAN mode It has no SLEEP function. 5. When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted. When TIMER function is set, the quiet sleeping function can't be set up. After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on, if the two modes are set up at the same time, either of their operation time is ended first , the unit will stop automatically, and the other mode will be cancelled. 1 hr 1 hr Rises 1 C O O Rises1 C Unit stop Temp. setting In COOL, DRY mode Power Failure Resume Function If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. The green side of the bacteria-killing medium air purifying filter face outside, and the white side face the unit. 5. Close the Inlet Grille Close the Grille surely Detach old Air Purifying Filter NOTE: The photocatalyst air purifying filter will be solarized in fixed time. In normal family, it will be solarized every 6 months. 3. Attach Air Purifying Filter Put air purifying filter appliances into the right and left filter frames. The bacteria-killing medium air purifying filter will be used for a long time, no need for replacement. But in the period of using them , you should remove the dust frequently by using vacuum cleaner or flaping them lightly, otherwise , its performance will be affected. Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it, or its ability of sterilization will be reduced. 5 Cautions When abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. STRICT ENFORCEMENT Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. Use an exclusive power source with a circuit breaker WARNING WARNING Check proper installation of the drainage securely STRICT ENFORCEMENT OFF Connect power supply cord to the outlet completely Use the proper voltage STRICT STRICT ENFORCEMENT ENFORCEMENT Do not use power supply Take care not to damage the power supply cord. cord in a bundle. 1. Do not use power supply cord extended or connected in halfway 2. Do not install in the place where there is any possibility of inflammable gas leakage around the unit. 3. Do not get the unit exposed to vapor or oil steam. PROHIBITION Do not insert objects into the air inlet or outlet. PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on. PROHIBITION Do not channel the air flow directly at people, especially at infants or the aged. [. . . ] 5. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. . 7. The used batteries should be disposed of properly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09HEA13-B

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09HEA13-B will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag