User manual HAIER HSU-09HEK103/R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09HEK103/R2. We hope that this HAIER HSU-09HEK103/R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-09HEK103/R2.


Mode d'emploi HAIER HSU-09HEK103/R2
Download

You may also download the following manuals related to this product:

   HAIER HSU-09HEK103/R2 annexe 1 (2398 ko)

Manual abstract: user guide HAIER HSU-09HEK103/R2

Detailed instructions for use are in the User's Guide.

[. . . ] Place where the distance of more than lm from televisions, radios, wireless apparatuses and fluorescent lamps can be left. In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened. Place, which is less affected by rain or direct sunlight and is sufficiently ventilated. Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. [. . . ] In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials. 3 30mm Indoor unit Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 1(L ) 2(N) 34 3 4 Indoor unit HSU-09HEK03/R2 HSU-12HEK03/R2 Outdoor unit connecting wiring: -mod 09-12: 3G1. 0mm 2 + 2G0. 75mm2 Power cable: -mod 09-12: 3G1. 0mm 5 Outdoor unit 1. Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2. Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening torque 18N. m 42N. m 50N. m Liquid side 6. 35mm(1/4") Gas side 9. 52mm(3/8") Spanner Gas side 12. 7mm(1/2") Torque wrench Be careful that matters, such as wastes of sands, etc. shall not enter the pipe. When connecting pipe exceeds 7 meters, 20g refrigerant shall be added per exceeding meter. Charge according to the following list. for 9k 12k Piping length Additional amount 7m No need Outdoor unit 10m 60g Indoor unit A for 09K : A=15m for 12K : A=15m Oil trap Indoor unit Outdoor unit Max. Elevation:10 m CAUTION In case more than 5m Oil trap shoud be installed every 5~7m no more gas if the length of connecting pipe is less than 7m. The height difference between any two indoor or outdoor units can not be more than 10m. 3. Connection Use the same method on indoor unit. [. . . ] If the scale-moves back in spite of tightening, make flaring work again, the return to the beginning of . Close Liquid Side Gas Side 6. 35mm(1/4") 9. 52mm(3/8") 12. 7mm(1/2") 3-way valve Open the valve rod for the 2-way valve to an angle of anticlockwise 90 degrees. After 6 seconds, close the 2-way valve and make the inspection of gas leakage. 2-way valve Open 2-way valve 3-way valve Service port 90o 90ofor 6 sec. No gas leakage? In case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed steps. If it does not stop gas leakage, discharge whole refrigerants from the service port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder Detach the charge hose from the service port, open 2-way valve and 3-way. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09HEK103/R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09HEK103/R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag