[. . . ] Install an exclusive branch circuit of the power. A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated as they become Iow temperature in operation. Use optional parts for piping set or pipes covered with equivalent insulation material. [. . . ] Then temporarily fasten the plate with one steel nail. Make sure once more the proper level of the plate, by hanging a thread with a weight from the central top of the plate, then fasten securely the plate with the attachment steel nail. Find the wall hole location A using a measuring tape
A=80mm
35
120mm
Fit the level line
For the units with fresh air function
When the mounting plate is fixed side bar and lintel
Fix to side bar and lintel a mounting bar, Which is separately sold, and then fasten the plate to the fixed mounting bar. Refer to the previous article, " position of wall hole. When the mounting plate is first fixed ", for the
2. Making a Hole on the Wall and Fitting the Piping Hole Cover
Make a hole of 70 mm in diameter, slightly descending to outside the wall. Install piping hole cover and seal it off with putty after installation Indoor side Wall hole 70mm Outdoor side Thickness of wall
(Section of wall hole) G Piping hole pipe
3. Installation of the Indoor Unit Drawing of pipe
[ Rear piping ]
Draw pipes and the drain hose, then fasten them with the adhesive tape
[ Left
Left-rear piping ]
In case of left side piping, cut away, with a nipper, the lid for left piping. In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
3
70mm
70mm
Indoor unit
1. Insert the drain hose into the dent of heat insulation materials of indoor unit. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them. Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Heat insulation material
signal wire
Piping
Lid for right piping Lid for left piping Lid for under piping Fix with adhesive tape Drain hose
Drain hose Indoor/outdoor electric cable
Change-for-fresh-air tube
Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.
[Other direction piping]
Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. Insert the cable according to terminal number in the same manner as the indoor unit. If wiring is not correct, proper operation can not be carried out and controller may be damaged. Fix the cable with a clamp.
4. Attaching Drain-Elbow
If the drain-elbow is used, please attach it as figure. (Note: Only for heat pump unit. )
6
Outdoor unit
6. Purging Method:
Push the air out of the indoor unit and piping as followes: (1) Remove the valve cap on 2-way valve in outdoor unit. (2) Loosen by 1/2 turn the flare nut of gas pipe, which is conneted to 3-way valve. (3) Loosen 2-way valve by 90 using hexagon wrench, and after approx. Gas comes out through flare nut on wide pipe. If no gas is discharged, tighten flare nut with specified torque. (4) Open 2-way and 3-way valves using specified torque. (5) Tighten the caps on the valves with specified torque.
o
2-way valve Liquid Side 6. 35mm(1/4") Gas Side 9. 52mm(3/8") 12. 7mm(1/2")
3-way valve
Flare nut
2-way valve 6. 35mm(1/4")
3-way valve 9. 52mm(3/8") 12. 7mm(1/2")
Freshair-3 Freshair-2 HSU-09H03/U(ZXF) HSU-12H03/U(ZXF)
2-way valve 6. 35mm(1/4") 3-way valve 9. 52mm(3/8") 12. 7mm(1/2")
HSU-09C03/U(ZXF) HSU-12C03/U(ZXF)
Tighten torque N. m Valve rod Valve cap 7-9 20-25
When connecting pipe exceeds 5 meters, 16g refrigerant shall be added per exceeding meter. Piping length Additional amount 5m No need 7m 32g
10m
80g
Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according to the following list. [. . . ] Only for first installation, this extra 50g can be used to purge air in pipes. During this procedure, 50g refrigerant will be discharged in piping. (This must be strictly controlled within 90 and 10 sec. )
o
7
1. Power Source Installation
The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09HJ03/R1
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.