Manual abstract: user guide HAIER HSU-09LE04
Detailed instructions for use are in the User's Guide.
[. . . ] Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked is available as illustrated in the above figure.
Power Source
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate. [. . . ] Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape
Heat insulation material Lid for right piping Lid for under piping Lid for left piping
Piping
Drain hose
Indoor/outdoor electric cable
Fix with adhesive tape
Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.
[Other direction piping]
Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. When bending, be careful not to crash pipes. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially.
Fixing the indoor unit body
Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly.
4. Connecting the indoor/outdoor Electric Cable Removing the wiring cover
Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop.
4
Indoor unit
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm.
4
4
1(L) 2(N)
Indoor unit
HSU-09LE04 HSU-07LD03
Outdoor unit
Indoor unit
HSU-12LE04 FJT-12L
Outdoor unit
1 2
4
4
Outdoor unit
HSU-18LE04 FJT-18L FJT-24L connecting wiring: -mod 07-12: 3G1. 0mm -mod 18: 3G1. 5mm -mod 22: 4G0. 75mm -mod 24: 3G1. 5mm
POWER PLUG
Indoor unit
HSU-22LE04
power
LN
{
L N
Indoor unit
{
Outdoor unit
Power cable: -mod 07-12: 3G1. 0mm -mod 18: 3G1. 5mm -mod 22: 3G2. 5mm -mod 24: 3G1. 5mm
5
Outdoor unit
Outdoor unit 1. Installation of Outdoor Unit
Install according to Drawing for the installation of indoor and outdoor units
2. Connection of pipes
To bend a pipe, give the roundness as large as possible not to crush the pipe Connecting the pipe of gas side first makes working easier. [. . . ] (4) Open 2-way and 3-way valves using specified torque. (5) Tighten the caps on the valves with specified torque.
Tighten torque N. m Valve rod Valve cap 7-9 20-25 HSU-12LE04 HSU-18LE04 2-way valve 9. 52mm(3/8") FJT-24L FJT-18L 3-way valve 15. 88mm(5/8")
2-way valve 6. 35mm(1/4") 3-way valve 9. 52mm(3/8") 12. 7mm(1/2")
HSU-09LE04 HSU-07LD03 2-way valve 6. 35mm(1/4")
FJT-12L 3-way valve 12. 7mm(1/2") 15. 88mm(5/8")
When connecting pipe exceeds 5 meters, 20g or 60g (only for 22k 24k) refrigerant shall be added per exceeding meter. Charge according to the following list.
for 7k 9k 12k 18k
Piping length Additional amount 5m No need 7m 40g 10m 100g
for 22k 24k
Piping length 5m 7m 120g 10m 300g 20m 900g Additional amount No need HSU-22LE04
Indoor unit
Outdoor unit
A
Outdoor unit
A B
Indoor unit
B
Outdoor unit
A
C
Oil trap Indoor unit
B
Max. Elevation: Max. Length:
for 7K 9K 12K: B=5m for 18K 22K 24K: B=10m
for 7K 9K : A=7m for 12K : A=10m for 18K22K 24K : A=20m
CAUTION In case more than 5 metresoil trap C should be installed every 5~7m.
Note: When extending piping, air inside piping shall be removed by using external refrigerant gas, charge according to the following list. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09LE04
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.