Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09LEA03-N. We hope that this HAIER HSU-09LEA03-N user guide will be useful to you.
Lastmanuals help download the user guide HAIER HSU-09LEA03-N.
You may also download the following manuals related to this product:
HAIER HSU-09LEA03-N annexe 1 (1635 ko)
Manual abstract: user guide HAIER HSU-09LEA03-N
Detailed instructions for use are in the User's Guide.
[. . . ] Installation Manual of Room Air Conditioner
Read this manual before installation Explain sufficiently the operating means to the user according to this manual.
Necessary Tools for Installation
1. Driver 2. Hacksaw 3. Hole core drill 4. Spanner(17, 19 and 26mm) 5. Torque wrench(17mm, 22mm, 26mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap-and-water solution 11. Measuring tape 12. Reamer
Drawing for the installation of indoor and outdoor units
Accessory parts
1 2 3
Mounting plate Remote controller
1 2 1 1 6 4 1 4 1
Optional parts for piping Mark
A B C D E F G Parts name Non-adhesive tape Adhesive tape Saddle(L. S) with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover
mo re th an
R-03 dry battery
10c
m
4 5 6 7 8 9
more than 5cm
No.
Accessory parts
Number of articles
Drain hose 4X50 Steel nail, cement 4X25 Screw Plastic cap Cover Cushion
mo
re th
an
10c
m
Attention must be paid to the rising up of drain hose
A
Arrangement of piping directions
Rear left Left Rear right Below Right
mo re tha n1 0c m
C
Pipe supporting plate
mo
re th
an
10c
m
D E
more
than
60cm
more
than
15c
m
The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m.
No. 0010515136
256
140
415
140
140
500
140
113. 5
583
113. 5
Floor fixing dimensions of the outdoor unit (Unit:mm)
Floor fixing dimensions of the outdoor unit (Unit:mm)
HSU-12LEA03 HSU-18LEA03 HSU-18LEA13-W HSU-10LEA03-T HSU-13LEA03-T HSU-09LEB13-H HSU-09LEA13-H HSU-12LEA13-H HSU-14LEA13-H HSU-12LEB13-H HSU-14LEB13-H HSU-18LEA13-H HSU-12CRA03-T HSU-18CRA03-T AMS12H03-N AMS18H03-N PAS18L03-N(T3) HSU-18HEA13(T3) HSU-18HEA03(T3)
HSU-09HEA03/(DB) HSU-09HEA03/(BP) HSU-12HEA03/(DB) HSU-12HEA03/(BP) HSU-12LEA13-M HSU-18LEA13-M HSU-18LEA03(T3) HSU-18LEA13(T3) HSU-12LEA13-F HSU-12HEA03 HSU-18HEA03 YKS-12HEA03 YKS-18HEA03 HSU-10LED03-T HSU-13LED03-T HSU-12LEN03 HSU-18LEN03 HSU-09HEC03 HSU-12HEC03
Floor fixing dimensions of the outdoor unit (Unit:mm)
HSU-05LEA03 HSU-07LEA03 HSU-09LEA03 HSU-09LEA13-W HSU-12LEA13-W HSU-09LEA13-F HSU-07HEA03 HSU-09HEA03 HSU-12HEB03 HSU-09CRA03-T AMS09H03-N YKS-09HEA03 HSU-09LEA03-N HSU-09LEN03
HSU-22LEA03 HSU-24LEA03 HSU-22LEA13-W AMS22H03-N HSU-22HEA03 HSU-24HEA03 YKS-22HEA03 HSU-18LED03-T HSU-18LED03-T1
HSU-18LEA03-T
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated as they become Iow temperature in operation. [. . . ] Pull out the cable on the front side, and connect the cable making a loop.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. A breaker should be incorporated into fixed wiring. [. . . ] Charge according to the following list.
for 5k 7k 9k 10k 12k 13k 18k
Piping length Additional amount 5m No need 7m 40g 10m Piping length 5m 100g Additional amount No need
Outdoor unit
for 22k 24k
7m 120g 10m 300g 20m 900g
Indoor unit
A
Outdoor unit
A B
Indoor unit
B
Outdoor unit
A
C
Oil trap Indoor unit
B
Max. Elevation: for 5K 7K 9K 10K 12K 13K: B=5m for 18K 22K 24K: B=10m Max. Length: for 5K 7K 9K 10K: A=7m for 12K 13K: A=10m for 18K 22K 24K: A=20m
CAUTION In case more than 5 metresoil trap C should be installed every 5~7m.
4 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09LEA03-N
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09LEA03-N will begin.