If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09LEK03-Y2. We hope that this HAIER HSU-09LEK03-Y2 user guide will be useful to you.
Lastmanuals help download the user guide HAIER HSU-09LEK03-Y2.
Manual abstract: user guide HAIER HSU-09LEK03-Y2INSTALLATION
Detailed instructions for use are in the User's Guide.
[. . . ] Installation Manual of Room Air Conditioner
Read this manual before installation Explain sufficiently the operating means to the user according to this manual.
Necessary Tools for Installation
1. Driver 2. Hacksaw 3. Hole core drill 4. Spanner(17, 19 and 26mm) 5. Torque wrench(17mm, 22mm, 26mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap-and-water solution 11. Measuring tape 12. Reamer
Drawing for the installation of indoor and outdoor units
Accessory parts
more than 5cm
mo re tha n1 0cm
No. [. . . ] Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. [. . . ] Length: for 5K 7K 9K 10K: A=7m for 12K 13K: A=10m for 18K 22K 24K: A=20m
CAUTION In case more than 5 metres oil trap C should be installed every 5~7m.
4 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09LEK03-Y2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.