Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09LH04. We hope that this HAIER HSU-09LH04 user guide will be useful to you.
Lastmanuals help download the user guide HAIER HSU-09LH04.
You may also download the following manuals related to this product:
HAIER HSU-09LH04 annexe 1 (194 ko)
Manual abstract: user guide HAIER HSU-09LH04
Detailed instructions for use are in the User's Guide.
[. . . ] SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-09LH03(DB) HSU-09LH04(DB)
Please read this operation manual before using the air conditioner
No. 00105
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that hoes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled . Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. [. . . ] Confirmation indicator: After pressing power ON/OFF, if no display, reload the batteries. Note: Full display or unclear display during operation indicates the batteries have been used up. Used two new same-typed batteries when loading. If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.
POWER/SOFT
7
Operation
HEALTH operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts. Health function includes health anion function, UV light degerming function.
2. Health anion function
Press HEALTH button. Air conditioner starts health anion function operation. For twice press, disappears, the operation stops. When indoor fan motor is running, it has healthy process function. (It's available under any mode)
POWER/SOFT
When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
BRIEF INTRODUCTION TO HEALTH ANION FUCTION
The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
8
Operation
Auto Operation
Remote controller
1. Unit start
Press ON/OFF on the remote controller, unit starts.
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN
Then
Select Auto operation
3. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
POWER/SOFT
LOW
MED
HI
AUTO
Air conditioner is running under displayed fan speed. Unit start
Press ON/OFF on the remote controller, unit starts.
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN
Then Select FAN operation
3. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
POWER/SOFT
LOW
MED
HI
4. Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in COOL mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP operation is not available.
12
Operation
Air Flow Direction Adjustment
1. Status display of air sending
Vertical flap
Pos. 1 Pos. 2 Pos. 3 Pos. 4
POWER/SOFT
Pos. 5 Pos. 6
(Auto swing)
2. Up and down air flow direction
For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN: remote controller: AUTO: remote controller:
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Pos. 6
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Pos. 5
Pos. 6
The vertical flap will swing according to the above positions
Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position.
14
Operation
Sleep Operation
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. In COOL, DRY mode 1 hours after SLEEP mode starts, temp. The unit will run for further 6 hours then stops. setting so that room temperature won't be too Iow for your sleep.
SLEEP operation starts SLEEP operation stops Approx. 6hrs Rises 1OC 1 hr
1 hr
Rises 1OC
Temp. setting
Unit stop
In COOL, DRY mode
2. In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode. [. . . ] Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
POWER
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects.
Once every two weeks
Close the inlet grille.
22
Maintenance
Replancement of Air Purifying Filter
1. Open the lnlet Grille
Open the inlet grille by pushing each ends of the inlet grille upward. (use thumbs to push up)
2. Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
3. Detach old Air Purifying Filter 4. Attach old Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames . Detach old Air Purifying Filter
5. Attach the standard air filter
(Necessary installation)
6. Close the Inlet Grille
Close the Grille surely
NOTE:
The air purifying filter of the bacteria-killing medium and the electrostatic air purifying filter accessories with machine will be used based on real situation. The bacteria-killing medium air purifying filter is available for a long time and needn't to be changed. But it must be noticed to use the vacuum cleaner frequently to adsorb the dusts covering the purifying filter lest the covering dusts effect the function of the bacteria-killing medium air purifying filter. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09LH04
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09LH04 will begin.