User manual HAIER HSU-09RC03/R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09RC03/R2. We hope that this HAIER HSU-09RC03/R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-09RC03/R2.


Mode d'emploi HAIER HSU-09RC03/R2
Download

You may also download the following manuals related to this product:

   HAIER HSU-09RC03/R2 annexe 1 (1552 ko)

Manual abstract: user guide HAIER HSU-09RC03/R2

Detailed instructions for use are in the User's Guide.

[. . . ] SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-09RC03/R2(DB) HSU-12RC03/R2(DB) HSU-18RC03/R2(DB) HSU-22RC03/R2(DB) Please read this operation manual before using the air conditione Cautions Safety Instructions and Warnings Disposal of the old air conditioner Before disposing an old air conditioner that Before starting the air conditioner, read the goes out of use, please make sure it's inopinformation given in the User's Guide careferative and safe. The User's Guide contains very imporin order to avoid the risk of child entrapment. observations relating to the assembly, tant operation and maintenance of the air conditioner. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. [. . . ] Unit stop Press HEALTH button, the healthy function stops. The pilot light of healthy process on the display board is extinguished. BRIEF INTRODUCTION TO HEALTH OPERATION The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air the room. Note When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion. 8 Operation Auto Operation Display panel Remote controller 1. Unit start Link with electronic power. Press ON/OFF on the remote controller, unit starts. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY F AN HEA T Then Select DRY operation 3. Select temp. setting Press TEMP. button Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will decrease rapidly Select a desired temperature. 4. Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: COOL operation starts when room temp. is higher than temp. setting. Ultra-low air flow LOW MED I H AUTO Tt2 ei mn pg . + sC eo T e m . p s t i n g On reaching temp. setting +2oC unit will run in mild DRY mode. Air conditioner is running under displayed fan speed In DRY mode, when room temperature becomes 2oC higher than temp. setting, unit will run intermittently at LOW speed regardless of FAN setting. 5. Unit stop Press ON/OFF button, the unit stops. 11 Operation Fan Operation Display panel Remote controller 1. Unit start Link with electronic power. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow). 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY F AN HEA T Then Select FAN operation 3. Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED I H 4. Unit stop Press ON/OFF button, the unit stops. About FAN operation In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP operation is not available. 12 Operation Heat Operation Display panel Remote controller 1. Unit start Link with electronic power. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow). 2. Select operation mode Press MODE button. For each press, operation mode changes as follows: Remote controller: AUTO COOL DRY F AN HEA T Then Select HEAT operation 3. Select temp. setting Press TEMP. button Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will decrease rapidly Select a desired temperature. 4. Fan speed selection Press FAN button. For each press, fan speed changes as follows: Remote controller: LOW MED I H AUTO Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. [. . . ] cloth. Do not use the following for cleaning Gasoline, benzine, thinner or cleanser may damage the coating of the unit. Hot water over 40OC(104OF) may cause discoloring or deformation. Air Filter cleaning Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. Clean the filter. Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects. Once every two weeks Close the inlet grille. 22 Maintenance Replacement of Air Purifying Filter 1. Open the lnlet Grille Open the inlet grille by pushing each ends of the inlet grille upward. (use thumbs to push up) 2. Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3. Detach old Air Purifying Filter 4. Attach old Air Purifying Filter Detach old Air Purifying Filter Put air purifying filter appliances into the right and left filter frames . The green aspect of the bacteria-killing medium air purifying filter will face outside, the white aspect will face to the machine. 5. Attach the standard air filter (Necessary installation) 6. Close the Inlet Grille Close the Grille surely NOTE: The air purifying filter of the bacteria-killing medium and the the multi-lights touchi intermediary accessories with machine will be used based on real situation. The bacteria-killing medium air purifying filter is available for a long time and needn't to be changed. But it must be noticed to use the vacuum cleaner frequently to adsorb the dusts covering the purifying filter lest the covering dusts effect the function of the bacteria-killing medium air purifying filter. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09RC03/R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09RC03/R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag