User manual HAIER HSU-09RS03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-09RS03-R2. We hope that this HAIER HSU-09RS03-R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-09RS03-R2.


Mode d'emploi HAIER HSU-09RS03-R2
Download
Manual abstract: user guide HAIER HSU-09RS03-R2

Detailed instructions for use are in the User's Guide.

[. . . ] the manual of how to display set temp Press LIGHT button continuously for ten times, the display temp on display panel can be changed from ambient temp to set temp. Set temp function only valuable for RS. Load the battery, then put on the cover again. Clock set 1 Press CLOCK button, "AM" or "PM" flashes. 23 22. POWER / SOFT button 23. 10 special heating set function: 10 degree heating maintaining (valuable for RS) 22 21 31 32 20 19 18 33 34 2 Press "+" or "-" to set correct time. AM PM 18. CODE button Used to select CODE A or B with a press, A or B will be displayed on LCD. Please select A without special explanation. 19. RESET button When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the controller normal. 24. HEALTH AIRFLOW button 25. HEALTH button 26. SWING UP/DOWN button 27. SWING LEFT/RIGHT button 28. FRESH button 29. SLEEP button 30. TIMER ON / OFF button 31. HOUR button 32. CANCEL/CONFIRM button Used to confirm timer and clock settings. SMART Each press will increase or decrease 1min. If the button is kept pressed, time will change quickly. 3 Confirm time. After time setting is confirmed, press CONFIRM, "AM "and "PM" stop flashing, while clock starts working. 20. INQUIRE button Inquire the external environmental temperature and the operating power of the machine. when the panel display "01", the 33. CLOCK button 34. LOCK button If pressed, the other buttons will be disabled. Press it once again, lock will be cancelled. Note: The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. [. . . ] Press POWER button again, POWER SMART will flash. Select your desired TIMER OFF. Remote controller: " TIMER OFF " will flash. disappears, the operation 2 Time setting. stops. SOFT Operation You can use this function when silence is needed for rest or reading. For each press, SOFT Every time the button is pressed, time setting increases or decreases 1 min, if kept depressed, it will increase rapidly. It can be adjusted within 24 hours. is displayed Air conditioner 3 Confirming your setting. After setting correct time, press CONFIRM button press CONFIRM button to confirm " ON "or" OFF " on the remote controller stops flashing. starts POWER function operation. In SOFT operation mode, fan speed automati cally takes low speed of AUTO fan mode. Press SOFT button again, SOFT disappears, the operation stops. TIMER ON OFF TIMER ON OFF press TIMER ON button to confirm, follow the same procedure in "Time setting for TIMER OFF " Remote controller: TIMER ON OFF press TIMER OFF button to confirm, follow the same procedure in "Time setting for TIMER ON " Remote controller: TIMER ON OFF Hints: During POWER operation, in rapid COOL mode, the room will show inhomogeneous temperature distribution. When the power resumes after power failure, the unit will run automatically, and 3 minutes later the compressor starts running. Note to the power failure resume: press the sleep button ten times in five seconds and enter function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds. 8 Operation iFP Operation The movement of people in the room can be sensed, which can improve the air adjustment efficiency. ECO Operation Automatic adjusting with the environmental temperature, running with power saving. 1 Press iFP button " and " iFP AM iFP " is Press ECONOMY button " ECO AM displayed on the remote controller " is displayed on the display board, unit will unrin iFP mode. SMART SMART ECO " is displayed on the remote controller, unit will run in ECONOMY operation. 2 Every time the button is pressed, display changes as follows: Remote controller: BLANK Press ECONOMY button For twice press, ECONOMY disappears, the operation stops. Detect the location of the human body, adjust the wind swing, blow the location where the body is. Detect the location of the human body, adjust the wind swing, avoid the location where the body is. When several people are located at different positions, or one person is moving in different areas, no matter whether the wind is blowing or not, the wind will automatically swing and blow to multi areas, the wind direction adjustment will be delayed, it cannot be deflected suddenly while detecting. In iFP, FOLLOW and EVADE operation mode, Press" button, the unit will not operate " " mode, Press " button, the operation stops. " " The power saving function only works under the cooling, heating or dehumidifying mode, after the power saving function is set, press the sharp, mute, sleep, or smart key to exit the power saving function. After the power saving is set, the host machine will automatically adjust the setting temperature, and automatically control the switch of the compressor, which may be inconsistent with the user's setting. The power saving function is more effective after the air conditioning has been running for a long time (more than 2 hours) The human body sensor is used to detect if the infrared ray is changing. It may be inaccurate in the following conditions: The human body keeps still (when reading or watching TV etc. ) or is blocked by barriers like screen, cabinet or glass. The person is wearing very thick clothes or the person is lying or sleeping. A pet is moving frequently, or the wind is blowing the curtains, or something in the room is swinging frequently. 9 Operation FRESH Operation Exhaust the vitiated air from the room, and inhale fresh air. (This function is unavailable on some models. ) Emergency operation and test operation Emergency Operation: Pi Press FRESH button " AM " is Use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, the"Pi" sound is heard once, which means the start of this operation. In this operation, the system automatically selects the operation modes, cooling tor fan or heat, according to the room temperature. Room temperature ABOVE 23 C BELOW 23 C O O displayed on the remote controller and " " is displayed on the display board, Operation mode COOLING HEAT Designated Timer temperature mode 26 O C 23 O C NO NO Air flow AUTOMATIC AUTOMATIC and the change-for-fresh-air function SMART operation begins. (cooling only uint) Room temperature BELOW 23 C O Operation Designated Timer mode temperature mode FAN 26 C O Air flow AUTOMATIC NO It is not possible to operate in dry mode. For twice press , the display " " Test operation: Test operation switch is the same as emergency switch. Pi Pi disappears and the change-for-freshair function operation is canceled. Use this switch in the test operation when the room temperature is below 16 o C, do not use it in the normal operation. Continue to press the test operation switch for more than 5 seconds. After you hear the"Pi" sound twice, release your finger from the switch:the cooling operation starts with the air flow speed "Hi". Note If the unit didn't install change-for-fresh-air electrical engine, change-for-fresh-air function is not available. For smart Use of The Air Conditioner About change-for-fresh-air function After the change-for-fresh-air function is initiated, the outside air can enter the indoors through the change-fresh-air tube thereby keeping the indoor air fresh. Setting the change-for-fresh-air function under the shutdown status, press the fresh air key and the remote controller displays the on status of air flow, low wind, and change-for-fresh-air functions, and now can set the timing open, timing close and time control switch. The dual fresh air has a memory function, which can be cancelled by pressing the key one time. Under the smart mode, after the machine has been running for a while, the dual fresh air function will be started automatically, it will be automatically stopped after continuously running for a while. Air Filter cleaning Open the inlet grille by pulling it upward Remove the filter Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. Clean the filter Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. Attach the filter Attach the filter correctly so that the "FRONT" indication is facing to the front. [. . . ] A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. 11 . The power plug and connecting cable must have acquired the local attestation. 12. In order to protect the units, please turn off the A/C first, and at least 30 seconds later, cutting off the power. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-09RS03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-09RS03-R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag