User manual HAIER HSU-10HA03(DB)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-10HA03(DB). We hope that this HAIER HSU-10HA03(DB) user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-10HA03(DB).


Mode d'emploi HAIER HSU-10HA03(DB)
Download
Manual abstract: user guide HAIER HSU-10HA03(DB)

Detailed instructions for use are in the User's Guide.

[. . . ] SPLIT AIR CONDITIONER OPERATION MANUAL AS102AMARA AU102ACARA (HSU-10HA03(DB)) AS102ALARA AU102ACARA (HSU-10H03(DB)) AS122AYARA AU122ACARA (HSU-12HA03(DB)) AS122AVARA AU122ACARA (HSU-12H03(DB)) Digital DC Variable Frequency Healthy Split Air Conditioner Please read this manual carefully before use. Please keep this manual carefully and safely. No. 0010540438 I Contents Cautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Name of Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4 Operation Hints. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-13 Notes for Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14-15 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-18 Trouble Shooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-21 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-30 Installation Check and Trial Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use. [. . . ] 6. 35 mm(1/4") 9. 52 mm(3/8") 12. 7 mm(1/2") Refrigeration Oil Connector Nut Piping Connection Hose Expander 1. Connecting Method To ensure the efficiency, the pipe should be as short as possible. Apply refrigerant oil at half union and flare nut. Spanner To bend a pipe, five the roundness as large as possible not to crash the pipe. When connecting pipe, hold the pipe center to center then screw nut on by hand, refer to the Drawing. Correct Be careful not to let foreign matters, such as sands enter the pipe. Tilting Fastening Torque Liquid pipe 6. 35mm(1/4") 18 N. m Gas Pipe 9. 52mm(3/8") 42 N. m Gas Pipe 12. 7mm(1/2") 50 N. m 26 + /- as illustrated. Spanner Not Correct cracks on expanded mouth burr incomplete too long 7 Operation Installation 1. Indoor Unit Mounting Plate Localization 3. Drill through Wall Small Hints: Remove the batteries in case the unit won't be in use for a long period. The remote controller will be self-checked after loading the new batteries by displaying all the symbols and resume working very soon. 4. After turning on the air conditioner, set to the desired mode: The remote controller displays the mode selected, the power light on the indoor unit lights up. Set Healthy Operation: Press the Health button once ion 5. Install Outdoor Unit is displayed and ion the power or healthy operation indicator turns from orange color to green. Now the air conditioner is operating the healthy function, meanwhile the anion generator in the indoor unit begins to release anion to clean the air and eliminate dust. Cancel Healthy Operation: Press the button Health again to stop the display, then the healthy operation stops. Notes: When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion. Brief Introduction to Health Operation The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of posion and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room. Check Drainage TEMP ON/OFF SWING FAN POWER RESET HEALTH 3 2 10. Wind up Pipes The step 4 and step 5 above can be adjusted according to the practical situation. This procedure is a reference to the installation person and customer, it can be adjusted according to the practical situation. 8 25 Installation To enable the air conditioner to work well, please install it as required by this manual. When moving the air conditioner, please don't scratch the shell. length of the connection pipe is 15 meters, and the max. [. . . ] The smell results from residents of tobacco smoke or cosmetics stuck inside of unit. During the cooling and dehumidifying operation, a thin white fog would be sprayed out of the indoor unit. It is a watery fog formed by a condensed air blew out of the unit. It smells. Clean the dust filter periodically: Blockage of the dust filter would reduce the cooling and heating effect, consume more power, water would be leaked during cooling, and other failures would also occur. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-10HA03(DB)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-10HA03(DB) will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag