User manual HAIER HSU-10HC03(B)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-10HC03(B). We hope that this HAIER HSU-10HC03(B) user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-10HC03(B).


Mode d'emploi HAIER HSU-10HC03(B)
Download
Manual abstract: user guide HAIER HSU-10HC03(B)

Detailed instructions for use are in the User's Guide.

[. . . ] Please ensure that the pipework of your air conditioner does not get damagedprior to being picked up by the relevant waste disposal center, and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal. Safety Instructions and Warnings Before starting the air conditioner, read the information given in the Operation manual carefully. The Operation manual contains very important observations relating to the assembly, operation and maintenance of the air conditioner. The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following instruction. Damaged air conditioners are not to be put into operation. [. . . ] Loading of the battery Load the batteries as illustrated right 2 R-03 (7#) batteries Remove the battery cover: Slightly press" "area and push down the cover as illustrated. Load the battery: Be sure that the loading is in line with the "+" / "-". request as illustrated on the bottom of the case. Confirmation indicator: After pressing power ON/OFF, if no display, reload the batteries. Note: Full display or unclear display during operation indicates the batteries have been used up. Used two new same-typed batteries when loading. If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key. POWER/SOFT 7 Operation HEALTH operation Remote controller 1. Unit start Press ON/OFF on the remote controller, unit starts. 2. Health negative ion function Press HEALTH button. Air conditioner starts health negative ion function operation. For twice press, disappears, the operation stops. POWER/SOFT When indoor fan motor is running, it has healthy process function. After another 1 hours, temp decrease by 2 OC further. The unit will run for further 3 hours then stops. setting so that room temperature won't be too high for your sleep. Temp. setting 1 hr Decreases 2OC 1 hr Decreases 2OC 3 hrs 3 hrs SLEEP operation starts Rises 1OC Unit stop SLEEP operation stops In HEAT mode POWER/SOFT 3. In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode. 5. Set the wind speed change when sleeping If the wind speed is high or middle before setting for the sleep, set for lowing the wind speed after sleeping. 6. Note to the power failure resume: press the sleep button ten times in five seconds and enter this function after hearing four sounds. And press the sleep button ten times within five seconds and leave this function after hearing two sounds. NOTE: With the power failure resume, when setting the TIMER ON, TIMER OFF and TIMER ON/OFF, itís memorized as shutdown status when resuming after power out. 15 Operation Timer On/Off Operation Set clock correctly before starting TIMER operation. After unit starts, select your desired operation mode Operation mode will be displayed on LCD. Timer mode selection Press TIMER button to change TIMER mode. Every time the button is pressed, display changes as follows: Remote controller: BLANK TIMER ON TIMER OFF TIMER ON-OFF Remote Controller Then select your desired TIMER mode (TIMER ON or TIMER OFF). " "or " "will flash. 3. Time setting Press HOUR button. [. . . ] When the remote controller is manipulated, it gets the system back to the normal operation mode. 20 Maintenance For Smart Use of The Air Conditioner Setting of proper room temperature Proper temperature Do not block the air inlet or outlet Close doors and windows Use the timer effectively during operation During cooling operation prevent the penetration of direct sunlight with curtain or blind If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch. OFF 21 Maintenance For Smart Use of The Air Conditioner WARNING Before maintenance, be sure to turn off the system and the circuit breaker. Remote Controller Indoor Body Do not use water, wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth. Wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping. then wipe off the detergent completely. Do not use the following for cleaning Gasoline, benzine, thinner or cleanser may damage the coating of the unit. Hot water over 40 C(104 F) may cause discoloring or deformation. O O Air Filter cleaning Open the inlet grille by pulling it upward. Remove the filter. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward. Clean the filter. Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade. Attach the filter. Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects. Once every two weeks Close the inlet grille. 22 Maintenance Replancement of Air Purifying Filter 1. Open the lnlet Grille Open the inlet grille by pushing each ends of the inlet grille upward. (use thumbs to push up) 2. Detach the standard air filter Slide the knob slightly upward to release the filter, then withdraw it. 3. Attach old Air Purifying Filter Put air purifying filter appliances into the right and left filter frames. Detach old Air Purifying Filter 4. Attach the standard air filter (Necessary installation) Note: the bacteria-killing mediums placed on the left side. the multi-lights touching intermediary is placed on the right side. 5. Close the Inlet Grille Close the Grille surely NOTE: The photocatalyst air purifying filter and the bacteria-killing medium air purifying filter will be used based on real situation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-10HC03(B)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-10HC03(B) will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag