User manual HAIER HSU-12C03/VA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-12C03/VA. We hope that this HAIER HSU-12C03/VA user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-12C03/VA.


Mode d'emploi HAIER HSU-12C03/VA
Download

You may also download the following manuals related to this product:

   HAIER HSU-12C03/VA annexe 1 (950 ko)

Manual abstract: user guide HAIER HSU-12C03/VA

Detailed instructions for use are in the User's Guide.

[. . . ] In the case of fixing the remote controller on a wall, place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened. Place, which is less affected by rain or direct sunlight and is sufficiently ventilated. Place, possible to bear the unit, where vibration and noise are not increased. Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked is available as illustrated in the above figure. Power Source Before inserting power plug into receptacle, check the voltage without fail. [. . . ] Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape Heat insulation material signal wire Piping Lid for right piping Lid for under piping Drain hose Lid for left piping Indoor/outdoor electric cable Change-for-fresh-air tube Fix with adhesive tape Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. [Other direction piping] Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole. When bending, be careful not to crash pipes. Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially. Fixing the indoor unit body Hang surely the unit body onto the upper notches of the mounting plate. Move the body from side to side to verify its secure fixing. In order to fix the body onto the mounting plate, hold up the body aslant from the underside and then put it down perpendicularly. 4. Connecting the indoor/outdoor Electric Cable Removing the wiring cover Remove terminal cover at right bottom corner of indoor unit, then take off wiring cover by removing its screws. When connecting the cable after installing the indoor unit 1. Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop. When connecting the cable before installing the indoor unit Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. 4 Indoor unit 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. 1(L) 2(N) Indoor unit Indoor unit Outdoor unit Indoor unit Outdoor unit Outdoor unit Connecting wiring 3G1. 0mm2 HSU-09C03/VA(ZXF) HSU-12C03/VA(ZXF) Connecting wiring 5G1. 0mm2 HSU-09H03/VA(ZXF) HSU-12H03/VA(ZXF) 1(L) 2(N) Connecting wiring 3G2. 5mm2 HSU-18C03/V(ZXF) For the units with fresh air function To indoor unit 1(L) 2(N) Indoor unit Connecting wiring 3G2. 5mm2 HSU-22C03/V(ZXF) HSU-22C03/V(ZF) HSU-24C03/V(ZXF) HSU-24C03/V(ZF) Indoor unit Outdoor unit HSU-12H03/VB(ZXF) HSU-12H03/V(ZXF) HSU-18H03/V(ZXF) HSU-22H03/V(ZXF) HSU-22H03/V(ZF) HSU-24H03/V(ZXF) HSU-24H03/V(ZF) HSU-24HK0307 HSU-24HD0307 Power cable: -mod 09-12: 3G1. 0mm2 -mod 18: 3G1. 5mm2 -mod 22-24: 3G2. 5mm2 Outdoor unit Connecting wiring -mod 12: 5G1. 0mm2 -mod 18-22-24: 3G2. 5mm2+2x0. 75mm2 To outdoor fresh air motor The connecting method of fresh air box signal wire 5. Installation instruction on the indoor part of the fresh air device 1. Two ways for the installation of indoor part, as illustrated: Way One:(For all the models) In the guard ring, connect outlet joint with the fresh air tube . Way Two(Only for the models of 09, 12): Insert the joint of water collecting pan into the fresh air tube, then connect the other end of joint with mesh enclosure of water collecting pan. Outlet joint (in guard ring) Joint of water collecting pan Fresh air tube Guard ring Fresh air tube Installation way One Installation way Two 2. Another way for the models of 18, 22 , 24, as illustrated: Way One (right direction): Take off the lid for right piping pipe, put the Outlet joint into the lid, then put the fresh air tube into the outlet jont. Way Two (left direction): Take off the lid for leftt piping pipe, put the Outlet joint into the lid, then put the fresh air tube into the outlet jont. Outlet joint Lid for under piping Fix with adhesive tape Change for fresh air tube Drain hose Lid for left piping 5 Outdoor unit 6. Easily-demount cleaning of indoor unit 1. Top inlet can be taken down Open the inlet grille, press the claw of the clip on the unit, then take down the top inlet. (according to figure 1) 2. Vertical flap can be taken down Overturn the vertical flap, press the claw of the clip , then take down vertical flap. (according to figure 2) 3. Horizontal louvers can be taken down After taking down vertical flap. Horizontal louvers are appeared, draw the middle louver, and take down the horizontal louvers . (according to figure 3) Figure 1 Figure 2 claw of the clip Figure 2 Daff Outdoor unit 1. Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units Figure 3 2. Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. Connecting the pipe of gas side first makes working easier. The max vertical distance between the indoor unit and the outdoor unit is 5 m. [. . . ] For installation in other places, use a circuit breaker as far as possible. 2. Cutting and Flaring Work of Piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. A Pipe diameter( 6. 35mm(1/4") 9. 52mm(3/8") 9. 52mm(3/8") 12. 7mm(1/2") 15. 88mm(5/8") ) Size A(mm) 0. 8~1. 5 1. 0~1. 8 1. 0~1. 8 1. 2~2. 0 1. 2~2. 0 Liquid side Flare tooling die 1. Cut pipe 2. Remove burs Liquid side Gas side Gas side Gas side 3. Insert the flare nut Correct 4. Flare pipe Incorrect Lean Damage of flare Crack Partial Too outside 3. On Drainage Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below. Less than 5cm It becomes high midway. The end is immersed in water. It waves. The gap with the ground is too small There is the bad smell from a ditch Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out surely to outdoor. In case that the attached drain hose is in a room, please apply heat insulation to it without fail. Check for Installation and Test Run Please kindly explain to our customers how to operate through the instruction manual. Check Items for Test Run Gas leak from pipe connecting? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12C03/VA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12C03/VA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag