User manual HAIER HSU-12C13

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-12C13. We hope that this HAIER HSU-12C13 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-12C13.


Mode d'emploi HAIER HSU-12C13
Download
Manual abstract: user guide HAIER HSU-12C13

Detailed instructions for use are in the User's Guide.

[. . . ] Air Conditioner Edition:2006/01/09 OPERRATION Air Conditioner Edition:2006/01/09 Caution Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner Consult your local authorities for the name and address of the waste materials collecting in order to avoid the risk of child entrapment. centers and waste paper disposal services nearest to your house. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. [. . . ] Each press will increase or decrease 1min. If the button is kept depressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working. NOTE: Cooling only unit do not have displays and functions related with heating Hints After replacing with new batteries, remote controller will conduct self-check, displaying all information on LCD. Then, it will become normal. Air Conditioner Edition:2006/01/09 Operation Remote controller's operation When in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the controller, prevent it from being damaged. When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter. Loading of the battery Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder) Remove the battery cover: Slightly press " " and push down the cover. *7# **** *, * **** **** *** **, * **** **** , * **** *** **** *, 6* **** ** **** **** **** **** **** *********7# **, ******, * *********** ********, * *****, 6**** ****** ******** ******** *********7# **, ******, * *********** ********, * *****, 6**** ****** ******** ******** Load the battery: Be sure that the loading is in line with the" + "/"-" pole request as illustrated. Put on the cover again Confirmation indicator: In disorderation, reload the batteries or load the new batteries after 6mins. Note: Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key. Hint: Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key. Power failure resume(please set and apply as necessary) If sudden power failure occurs, the unit will resume original operation when power is supplied again. Note: When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press ON/OFFto turn off the unit when power resumes. Air Conditioner Edition:2006/01/09 Operation Auto run, Fan operation (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. Enjoy yourself by just a gentle press. (2) Select operation mode Press MODE button. For each press, operation mode changes as follows: ON/OFF TEMP 1 4MODE 2 FAN SET AUTO COOL DRY HEAT FAN TIMER Unit will run in selected mode. Stop display at " " AUTO or " 3 "FAN. SWING CLOCK (3) FAN Press FAN button. For each press, fan speed changes as follows: SLEEP LOCK RESET AUTO LO MED HI (4) Unit stop Unit will run at selected fan speed. Vertical flap closed automatically. Hints Remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reelecting is needed. (TIMER ON/OFF needs reelecting) Cautions: Note: On cooling only unit, heating mode is not available, The above information is the After replacing batteries, press ON/OFF, and display explanation of the displayed becomes as follows: information therefore varies Operation mode: AUTO, Temp. No with those displayed in actual Timer mode: No, Fan speed :AUTO operation. Air Conditioner Edition:2006/01/09 Operation COOL, HEAT and DRY operation Recommendations: (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator on indoor unit lights up. Use COOL in summer. Use HEAT in winter Use DRY in spring, autumn and in damp climate. (2) Select operation mode Press MODE button. [. . . ] When the emergency operation switch is pressed, a" Pi "sound starts once, which means the start of this operation. In this operation, it is not possible to change the Pi settings of temperature and air flow speed, it is also impossible to do an operation by the timer. Room Designated temperature temperature More than 23 C Less than 23 C o o Timer mode Air flow Operation speed mode COOL HEAT 26 C 23 C o o CONTINUOUS AUTO CONTINUOUS AUTO If an air conditioner is a model for both cooling and heating. Cooling when the room temperature at the start of operation is above 23 C. o Heating when the room temperature at the start of operation is below 23 C o Test operation: Use this switch in the test operation when the room o temperature is less 16 C, do not use it in the normal operation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12C13

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12C13 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag