User manual HAIER HSU-12HM03 annexe 1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-12HM03. We hope that this HAIER HSU-12HM03 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-12HM03.


Mode d'emploi HAIER HSU-12HM03
Download
Manual abstract: user guide HAIER HSU-12HM03annexe 1

Detailed instructions for use are in the User's Guide.

[. . . ] OPERATION MANUAL Please read this operation manual before using the air conditioner. No. 0010544529 Cautions Disposal of the old air conditioner Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled. [. . . ] setting so that room temperature won't be too low for your sleep. SLEEP operation starts SLEEP operation stops Approx. 2 hrs 3 hr Rises 1 °C 3 hr Rises 1 °C Temp. setting Unit stop In COOL, DRY mode Remote Controller 2. In HEAT mode 3 hours after SLEEP mode starts, temp. The unit will run for further 2 hours then stops. setting so that room temperature won't be too high for your sleep. Temp. setting 3 hr Decreases 1°C 3 hr Decreases 1°C Unit stop TEMP HEALTH ON OFF FAN MODE 2 hr SWING SET SLEEP CLOCK SLEEP operation starts SLEEP operation stops TIMER POWER/SOFT In HEAT mode RESET LIGHT LOCK 6. If the sleep time in cooling, dehumidifying and heating run is less than 8 hours Within the set sleep time, the conditioner will run as per the procedure described in 1 and 2. It will be switched off automatically when the sleep time is expired. 3. In AUTO mode The unit operates in corresponding sleep SLEEP mode adapted to the automatically selected operation mode. 4. In FAN mode It has timing off function. The sleep time can be adjusted within the range of 1-8 hours. The remote controller will display " ", and display the timing off and detail off time in the timing off setting area. Push the time adjusting button to adjust the detail sleep time. Operation Timer On/Off Operation Remote Controller BLANK AM AM AM TIMER ON TIMER OFF TIMER ON-OFF TEMP HEALTH ON OFF 1 FAN MODE SLEEP SWING CLOCK SET TIMER 4 3POWER/SOFT 5 3 LIGHT LOCK 2 RESET Operation BLANK AM AM AM TIMER ON TIMER OFF TIMER ON-OFF Operation POWER/SOFT Operation POWER Operation When you need rapid heating or cooling, you can use this function. Selecting of POWER operation Press POWER/SOFT button. Every time the button is pressed, display changes as follows: BLANK SOFT POWER Stop the display at " TEMP ". HEALTH ON OFF FAN In POWER operation status: In HEAT or COOL mode, fan speed automatically runs in HI mode for 15 min then returns to original status setting. To cancel POWER operation Press POWER/SOFT button twice, POWER/SOFT disappears. MODE SLEEP SWING CLOCK SET TIMER POWER/SOFT RESET LIGHT LOCK SOFT Operation You can use this function when silence is needed for rest or reading. Selecting of SOFT operation Press POWER/SOFT button. Every time the button is pressed, display changes as follows: BLANK POWER SOFT Stop the display at " ". In SOFT operation mode, fan speed automatically takes "LO". To cancel SOFT operation Press POWER/SOFT button once, HI/SOFT disappears. Hints: During POWER operation, in rapid HEAT or COOL mode, the room will show inhomogeneous temperature distribution. Long period SOFT operation will cause effect of not too cool or not too warm. Operation TEMP HEALTH ON OFF FAN MODE SLEEP SWING CLOCK SET TIMER POWER/SOFT RESET LIGHT LOCK Operation About natural air function Natural air means that the air conditioner runs with analog natural airflow and automatically changes air speed to avoid human discomfort due to long exposure to strong wind. About human sensing function Human sensing function is to detect indoor human activity with a human sensor. After human sensing is actuated, if the unit keep detecting no human activity for 20 min, it will automatically enters standby (monitor) status, during which the unit will automatically start and resume operation if sensing human activity. [. . . ] To bend a pipe, give the roundness as large as possible not to crush the pipe. Connecting the pipe of gas side first makes working easier. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening Torque 18N. m 50N. m Liquid Side 6. 35mm(1/ 4") Spanner Torque wrench Gas Side 12. 7mm(1/ 2") 3 Connection Use the same method on indoor unit. Loosen the screws on terminal block and insert the plugs fully into terminal block, then tighten the screws. Insert the cable according to terminal number in the same manner as the indoor unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12HM03

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12HM03 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag