Detailed instructions for use are in the User's Guide.
[. . . ] SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-07RS03/R2 HSU-09RS03/R2 HSU-12RS03/R2 HSU-18RS03/R2 HSU-22RS03/R2 H2SM-18HS03/R2 HSU-09HS03/R2(DB) HSU-12HS03/R2(DB) HSU-18HS03/R2(DB) HSU-22HS03/R2(DB) HSU-12HSB03/R2(DB)
Please read this operation manual before using the air conditioner. No.
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. [. . . ] For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select COOL operation
3. Select temp. setting
Press TEMP. button Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will decrease rapidly Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5. Unit stop
Press ON/OFF button, the unit stops.
10
Operation
Dry Operation
1. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select DRY operation
3. Select temp. setting
Press TEMP. button Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will decrease rapidly Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
COOL operation starts when room temp. is higher than temp. setting.
Ultra-low air flow
Air conditioner is running under displayed fan speed In DRY mode, when room temperature becomes 2oC higher than temp. setting, unit will run intermittently at LOW speed regardless of FAN setting.
Temp. setting+2oC Temp. setting On reaching temp. setting +2oC unit will run in mild DRY mode.
5. Unit stop
Press ON/OFF button, the unit stops.
11
Operation
Fan Operation
Remote controller
1. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select FAN operation
3. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI
4. Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP operation is not available.
12
Operation
Heat Operation
Remote controller
1. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select HEAT operation
3. Select temp. setting
Press TEMP. button Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will decrease rapidly Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed fan speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
5. Unit stop
Press ON/OFF button, the unit stops.
13
Operation
Air Flow Direction Adjustment
1. Status display of air sending direction
Vertical flap
Pos. 1 Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 5 Pos. 6 Pos. 2 Pos. 3 Pos. 4 Pos. 5
Horizontal louvers
(Auto swing)
Pos. 6 Pos. 7 Pos. 8
2. Up and down air flow direction
For each press of button, air flow direction on remote controller displays as follows according to different operation modes: COOL/DRY/FAN: Pos. 1 Pos. 2 Pos. 3 Pos. 4 Pos. 6 remote controller: HEAT: remote controller: AUTO: remote controller:
Pos. 5 Pos. 4 Pos. 3 Pos. 2 Pos. 1 Pos. 6
Pos. 1
Pos. 2
Pos. 3
Pos. 4
Pos. 5
Pos. 6
The vertical flap will swing according to the above positions
3. Left and right air flow direction
For each press of remote controller:
Pos. 1 Pos. 2 Pos. 3
button, remote controller displays as follows :
Pos. 4 Pos. 5 Pos. 6 Pos. 7 Pos. 8
The horizontal louvers will swing according to the above positions. Note:When restart after remote turning off, the remote controller will automatically memorize the previous set swing position. 14
Operation
Sleep Operation
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep. Use of SLEEP function After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set. [. . . ] Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects.
Once every two weeks
Close the inlet grille.
22
Maintenance
Replacement of Air Purifying Filter
1. Open the lnlet Grille
Open the inlet grille by pushing each ends of the inlet grille upward. (use thumbs to push up)
2. Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
3. Detach old Air Purifying Filter 4. Attach old Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames . Detach old Air Purifying Filter
5. Attach the standard air filter
(Necessary installation)
6. Close the Inlet Grille
Close the Grille surely
NOTE:
The air purifying filter of the bacteria-killing medium and the electrostatic air purifying filter accessories with machine will be used based on real situation. The bacteria-killing medium air purifying filter is available for a long time and needn't to be changed. But it must be noticed to use the vacuum cleaner frequently to adsorb the dusts covering the purifying filter lest the covering dusts effect the function of the bacteria-killing medium air purifying filter. [. . . ]