User manual HAIER HSU-12LEK13-M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU-12LEK13-M. We hope that this HAIER HSU-12LEK13-M user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU-12LEK13-M.


Mode d'emploi HAIER HSU-12LEK13-M
Download

You may also download the following manuals related to this product:

   HAIER HSU-12LEK13-M annexe 1 (4156 ko)

Manual abstract: user guide HAIER HSU-12LEK13-M

Detailed instructions for use are in the User's Guide.

[. . . ] Installation Manual of Room Air Conditioner Read this manual before installation Explain sufficiently the operating means to the user according to this manual. Necessary Tools for Installation 1. Driver 2. Hacksaw 3. Hole core drill 4. Spanner(17, 19 and 26mm) 5. Torque wrench(17mm, 22mm, 26mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap-and-water solution 11. Measuring tape 12. Reamer Drawing for the installation of indoor and outdoor units Accessory parts 1 2 3 Mounting plate Remote controller 1 2 1 1 6 4 1 1 4 1 1 Optional parts for piping Mark A B C D E F G Parts name Non-adhesive tape Adhesive tape Saddle(L. S) with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover mo re tha n R-03 dry battery 10c m 4 5 6 7 8 9 10 11 more than 5cm No. Accessory parts Number of articles Drain hose 4X50 Steel nail, cement 4X25 Screw Plastic cap mo re tha n1 0cm Attention must be paid to the rising up of drain hose A Drain-elbow Cover Cushion Arrangement of piping directions Rear left Left Rear right Below Right mo re tha n1 0c m C re t mo m 10c han Pipe supporting plate Connecting cable Note:Cooling only units don't have Drain-elbow E D more than 60cm mor e than 15c m The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. No. 0010518787 256 140 415 140 140 500 140 113. 5 583 113. 5 Floor fixing dimensions of the outdoor unit (Unit:mm) Floor fixing dimensions of the outdoor unit (Unit:mm) Floor fixing dimensions of the outdoor unit (Unit:mm) HSU-09LEK13 HSU-12LEK13 HSU-07LEK03 HSU-07HEK03 HSU-09LEK03 HSU-12LEK03 HSU-09HEK03 HSU-12HEK03 HSU-09LEK03/ (DB) HSU-12LEK03/ (DB) HSU-18LEK13 HSU-108CH09 HSU-138CH09 HSU-12LEK13-M HSU-18HEK03 HSU-24LEK13 HSU-18LEK03/(DB) HSU-24HEK03 Selection of pipe To this unit, both liquid and gas pipes shall be insulated as they become Iow temperature in operation. [. . . ] Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW). If the fuse on PC board is broken please change it with the type of T. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. A breaker should be incorporated into fixed wiring. [. . . ] Charge according to the following list. for 5k 7k 9k 10k 12k 13k 18k Piping length Additional amount 5m No need 7m 40g 10m Piping length 5m 100g Additional amount No need Outdoor unit for 22k 24k 7m 120g 10m 300g 20m 900g Indoor unit A Outdoor unit A B Indoor unit B Outdoor unit A C Oil trap Indoor unit B Max. Elevation: for 5K 7K 9K 10K 12K 13K: B=5m for 18K 22K 24K: B=10m Max. Length: for 5K 7K 9K 10K: A=7m for 12K 13K: A=10m for 18K 22K 24K: A=20m CAUTION In case more than 5 metresoil trap should be installed every 5~7m. C 4 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12LEK13-M

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12LEK13-M will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag