[. . . ] Every time the button is pressed, display changes as follows:
BLANK POWER SOFT
Power indicator (Lights up when unit starts. )
Timer mode indicator
(Lights up whenTimer operation is selected. )
1. Mode display
Operation mode indicator
(lights up when the compressor is on. )
Remote signal receiver
(A beeping sound is generated when a signal from remote controller isreceived. )
Ambient temp display
When receiving the remote control signal, display the set temperature and in the rest time the room temperature is is displayed and this room temperature is only for reference.
2. FAN SPEED display
AUTO
AUTO COOL DRY HEAT FAN
LO
MED
HI
Horizontal flap
adjust up and down air flow Don't adjust it manually
4. HEALTH Used to operate the healthy function and LCD display.
Actual inlet grille may vary from the one shown in the manual according to the product purchased
NOTE: Cooling only unit do not have displays and functions related with heating If the unit which you purchased has healthy function, follow it. If not, please ignore.
Outdoor Unit
Loading of the battery
Remove the battery cover;
Load the batteries as illustrated. [. . . ] If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key
OUTLET INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
Clock set
Press CLOCK button, "AM" or "PM" flashes. Each press will increase or decrease 1min. If the button is kept pressed, time will change quickly. After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working.
POWER/SOFT
TIMER CLOCK
LIGHT
SET
SLEEP
1
Operation
Unit start / stop
Press ON/OFF button, unit starts or stops.
HEALTH ON/OFF
Auto Operation
According to the automatic choice system in temperature in indoors cold or make the hot movement
FAN MODE FAN
FAN
Select temp. setting
SWING
MODE
SWING
Operation Mode
Remote Controller
Note
Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Dry Operation
AUTO COOL DRY HEAT
In DRY mode, when room temperature becomes lower than temp. setting+2 oC, unit will run intermittently at LOW speed regardless of FAN setting.
FAN
FAN
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP operation is not available.
MODE
SWING
Cool Operation
Note:
In DRY mode, when room temperature becomes lower than temp. setting+2oC, unit will run intermittently at LOW speed regardless of FAN setting.
Fan Operation
FAN
MODE
SWING
the air conditioner automatically adjusts HEALTH ON/OFF HI the fan speed according AUTO LO MED to roomtemperature. FAN 2. In FAN operation mode the unit will not operate MODE in COOL mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled.
1. When FAN is set to AUTO,
Heat Operation Air Flow Direction Adjustm
(1)
FAN
MODE
FAN
MODE
SWING
SWING
Note:
In HEAT mode, warm air will blow out after a short periodof the time due to cold-draft prevention function.
When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.
Cooling only unit do not have displays and functions related with heating
Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.
2
Operation
HEALTH Operation
(This function is unavailable on some models. )
POWER/SOFT Operation
(This function is unavailable on some models. )
(1) POWER Operation
HEALTH ON/OFF
When you need rapid heating or cooling, you can use this function.
POWER/SOFT
FAN
TIMER
CLOCK
LIGHT
In COOL mode, fan speed automatically takes high speed of AUTO fan mode. But in the period of using them , you should remove the dust frequently by using vacuum cleaner or flaping them lightly, otherwise , its performance will be affected.
Please keep the bacteria-killing medium air purifying filter in the cool and dry conditions avoid long time directly sunshine when you stop using it, or its ability of sterilization will be reduced.
5
Cautions
WARNING
Please call Sales/Service Shop for the Installation. During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system. ) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes. During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air. In DRY mode, when room temperature becomeslower than temp. setting+2 oC, unit will run intermittently at LOW speed regardless of FAN setting. Is fuse blownout?
Is the air filter dirty?Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? [. . . ] If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F 3. If the fuse on PC board is broken please change it with a fuse type T. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-16CB03R1
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.