[. . . ] If not, please ignore. ) 7 TIMER OFF display TIMER ON display SLEEP display Dry display 4. POWER/SOFT button This function is unavailable on some models. POWER/SOFT display This function is unavailable on some models. NOTE: Cooling only unit do not have displays and functions related with heating If the unit which you purchased has healthy function, follow it. If not, please ignore. Outdoor Unit Loading of the battery 2 1 3 1 Remove the battery cover; 2 Load the batteries as illustrated. 2 R-03 batteries, resetting key(cylinder); OUTLET INLET CONNECTING PIPING AND ELECTRICAL WIRING 4 1 DRAIN HOSE 4 is in line with the " + "/"-"; Load the battery, then put on the cover again. 3 Be sure that the loading Clock set Press CLOCK button, "AM" or "PM" flashes. [. . . ] After time setting is confirmed, press SET, "AM "and "PM" stop flashing, while clock starts working. MODE SET Note: The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. When electronic-started type fluorescent lamp or change-over wireless telephone is installed in the type fluorescent lamp or room, the receiver is apt to be disturbed in receivingthe signals, so the distance to the indoor unit should be shorter. Full display or unclear display during operation indicates the batteries have been used up. If the remote controller can't run normally during operation, please remove the batteries and reload several minutes later. Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key FAN TIMER Hint: SWING CLOCK 1 Operation Press ON/OFF button, unit starts or stops. O Unit start / stop ON/OFF TEMP Auto Operation According to the automatic choice system in temperature in indoors cold or make the hot movement MODE SET ON/OFF TEMP Select temp. setting ON/OFF TEMP MODE SET MODE SET Operation Display Board Mode Remote Controller Note Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. Dry Operation AUTO COOL DRY HEAT In DRY mode, when room temperature becomes lower than temp. setting+2 oC, unit will run intermittently at LOW speed regardless of FAN setting. ON/OFF TEMP FAN nothing In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP operation is not available. MODE SET Note: Cool Operation In DRY mode, when room temperature becomes lower than temp. setting+2oC, unit will run intermittently at LOW speed regardless of FAN setting. Fan Operation 1. When FAN is set to AUTO, (This function is unavailable on some models. ) ON/OFF TEMP MODE SET the air conditioner automatically adjusts HI the fan speed according AUTO LO MED MODE SET to room temperature. 2. In FAN operation mode TIMER FAN the unit will not operate in COOL mode but only SWING in FAN mode , AUTO is not available in FAN mode. And temp. setting isCLOCK disabled. Heat Operation Air Flow Direction Adjustm (1) FAN ON/OFF TEMP TIMER SWING CLOCK MODE SET SLEEP HEALTH Note: When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature. In HEAT mode, warm air will blow out after a short periodof the time due to cold-draft prevention function. Cooling only unit do not have displays and functions related with heating Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status. 2 Operation HEALTH Operation (This function is unavailable on some models. ) POWER/SOFT Operation (1) POWER Operation (This function is unavailable on some models. ) When you need rapid heating or cooling, you can use this function. SWING CLOCK SWING CLOCK SLEEP HEALTH POWER/SOFT SLEEP HEALTH POWER/SOFT In COOL mode, fan speed automatically takes high speed of AUTO fan mode. (This noise is generated by refrigerant flowing in the system. ) During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes. Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells from the interior air such as the smell of furniture, paint, cigarettes. During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air. In DRY mode, when room temperature becomeslower than temp. setting+2 oC, unit will run intermittently at LOW speed regardless of FAN setting. Is fuse blownout? Is the air filter dirty?Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet?Are there some doors or windows left open?Is there any direct sunlight through the window during the cooling operation?(Use curtain) Are there too much heat sources or too many people in the room during cooling operation? Cautions The machine is adaptive in following situation 1. Applicable ambient temperature range: For: T1 Cooling Heating For: T3 Noise is heard Maximum: D. B / W. B Minimum: D. B / W. B Maximum: D. B Outdoor Minimum: D. B Maximum: D. B Indoor Minimum: D. B Maximum: D. B / W. B Outdoor Minimum: D. B / W. B Indoor 32 C/23 C o o 18 C/14 C o o 43 C/26 C o 18 C o 27 C o 15 C o o 24 C/18 C o o -7 C/-8 C o o o o Indoor Cooling Normal Performance inspection Maximum: D. B / W. B 29 C/19 C o o Minimum: D. B / W. B 18 C/14 C o o Smells are generated. [. . . ] If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F 3. If the fuse on PC board is broken please change it with a fuse type T. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-16H03R1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-16H03R1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag