[. . . ] SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL
HSU-09HEA03 HSU-12HEA03 HSU-12HEB03 HSU-18HEA13(T3) HSU-18HEA03(T3) HSU-18LEA13(T3) HSU-18LEA03(T3)
Please read this operation manual before using the air conditioner.
0010522564
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled . Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. [. . . ] The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the controller, prevent it from being damaged. r When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receivering the signals so the distance to the indoor unit should be shorter. Loading of the battery Load the batteries as illustrated. 2 R-03 batteries, resetting key (cylinder) Remove the battery cover:
HEA LTH ON/ OFF FAN DE MO
SW
TIM
ING
ER
CLO
CK
SET
K LOC
EP SLE
RES
ET
Slightly press " Load the battery:
" and push down the cover.
Be sure that the loading is in line with the" + "/"-" pole request as illustrated. Put on the cover again Confirmation indicator: In disorderation, reload the batteries or load the new batteries after 6 mins.
Note:
Use two new same-typed batteries when loading. If the remote controller can't run normally or doesn't work at all, use a sharp pointed item to press the reset key.
Hint:
Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out just need to press reset key. Power failure resume(please set and apply as necessary) If sudden power failure occurs, the unit will resume original operation when power is supplied again.
Note: When sudden power failure happens during unit operation in power failure resume
mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is resupplied, or press ON/OFF to turn off the unit when power resumes. 7
Operation
Auto, Cool Dry, Heat and Fan operation
(1) Unit start
Press ON/OFF button, unit starts.
(2) Select operation mode
Press MODE button. For each press, operation mode changes as follows: Operation mode AUTO COOL Remote controller Display board
SWING
HEALTH ON/OFF
DRY
HEAT
FAN
FAN MODE
Unit will run in selected mode.
TIMER CLOCK
(3) Select temp. o Every time the button is pressed, temp. setting increases 1 C o Every time the button is pressed, temp. setting decreases 1 C Unit will start running to reach the temp. setting on LCD.
SET
SLEEP
LOCK
RESET
(4) FAN
Press FAN button. For each press, fan speed changes as follows:
AUTO LO MED HI
Unit will run at selected fan speed. COOL or DRY mode , otherwise, condensate water might occur.
Hints
As cold air flows downward in COOL mode, adjusting air flow horizontally will be much more helpful for a better air circulation. As warm air flows upward in HEAT mode, adjusting air flow oblique downwards will be much more helpful for a better air circulation.
9
Operation
HEALTH Operation
1. Unit start
Press the ON/OFF switch
HEALTH
ON/OFF
2. Health anion function
FAN
Press HEALTH button remote controller and display board .
is displayed on the is displayed on the
TIMER
MODE
SWING
CLOCK
SET
SLEEP
3. To Cancel HEALTH Model
Press the " HEALTH"again, then the healthy function stops. .
LOCK
RESET
When indoor fan motor is running, it has healthy process function. (It's available under any mode)
NOTE:
If the unit which you purchased has healthy function, follow it. If not, please ignore.
Brief introduction to health anion function
The anion generator in the air conditioner can generate a lot of anion effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
10
Operation
TIMER Operation
Set Clock correctly before starting Timer operation
You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night.
TIMER ON/OFF
(1)After unit start, select your desired operation mode.
Operation mode will be displayed on LCD. Power indicator on indoor unit lights up.
HEALTH ON/OFF
(2)TIMER mode selection
PressTIMER button to change TIMER mode. Every time the button is pressed, display changes as follows:
ON
AM
FAN
MODE
OFF
PM
ON
AM N 12:00
OFF
ON
PM
OFF
12:00
blank
SWING
12:00
12:00
TIMER CLOCK
TIMER ON
TIMER OFF
TIMER ON-OFF
TIMER ON-OFF
Select your desired TIMER mode (TIMER ON or TIMER OFF), ON or OFF will flash.
SET
SLEEP
LOCK
RESET
(3)Timer setting
Press HOUR / button. [. . . ] Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Pi Pi
Removal of the restriction of emergency or test operation:
Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. When the remote controller is manipulated, it gets the system back to the normal operation mode.
14
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper temperature
Do not block the air inlet or outlet
Close doors and windows Use the timer effectively during operation
During cooling operation prevent the penetration of direct sunlight with curtain or blind
If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch.
OFF
15
Maintenance
For Smart Use of The Air Conditioner WARNING
Before maintenance, be sure to turn off the system and the circuit breaker.
Remote Controller
Indoor Body
Do not use water wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth.
Wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping. then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline, benzine, thinner or cleanser may damage the coating of the unit.
Hot water over 40 C(104 F) may cause discoloring or deformation.
O
O
Air Filter cleaning
Open the inlet grille by pulling it upward. Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects.
Once every two weeks
Close the inlet grille.
16
Maintenance
Replacement of Air Purifying Filter
1. Open the lnlet Grille
Prop up the inlet grille by using a small device named grille-support which located in the right side of the indoor unit.
2. Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
3. Attach Air Purifying Filter
Put air purifying filter appliances into the right and left filter frames. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-18HEA03
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.