[. . . ] SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
HSU-18H03/R2(DB) HSU-22H03/R2(DB)
Please read this operation manual before using the air conditioner.
No.
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable materials contained in an air conditioner can be recycled . Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. [. . . ] When indoor wind machine is running, it has healthy process function. (It's available under any mode)
3. Unit stop
Press HEALTH button, the health function stops. The pilot light of healthy process on the display board is extinguished.
BRIEF INTRODUCTION TO HEALTH OPERATION
The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air in the room.
Note
When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.
8
Operation
Auto Operation
1. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select DRY operation
3. Select temp. setting
Press TEMP. button Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will increase rapidly Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will decrease rapidly Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
COOL operation starts when room temp. is higher than temp. setting. Temp. setting+2oC Temp. setting
Ultra-low air flow
Air conditioner is running under displayed wind speed In DRY mode, when room temperature becomes 2OC higher than temp. setting, unit will run intermittently at LOW speed regardless of FAN setting.
5. Unit stop
On reaching temp. setting +2 C unit will run in mild DRY mode.
o
Press ON/OFF button, the unit stops.
11
Operation
Fan Operation
1. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
Then Select FAN operation
3. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI
4. Unit stop
Press ON/OFF button, the unit stops.
About FAN operation
In FAN operation mode, the unit will not operate in COOL or HEAT mode but only in FAN mode , AUTO is not available in FAN mode. And temp. setting is disabled. In FAN mode, SLEEP operation is not available.
12
Operation
Heat Operation
1. Press ON/OFF on the remote controller, unit starts. The liquid crystal will display the working state of last time (Except Timer, Sleep, Power/Soft and Health airflow).
Remote controller
2. Select operation mode
Press MODE button. For each press, operation mode changes as follows: Remote controller:
AUTO COOL DRY FAN HEAT
6
Then Select HEAT operation
3. Select temp. setting
Press TEMP. button Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will increase rapidly. Every time the button is pressed, temp. setting increase 1 C, if kept depressed, it will decrease rapidly. Select a desired temperature.
4. Fan speed selection
Press FAN button. For each press, fan speed changes as follows: Remote controller:
LOW MED HI AUTO
Air conditioner is running under displayed wind speed IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function. [. . . ] After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
Pi. . . Pi Pi
Removal of the restriction of emergency or test operation
Press the emergency operation switch once more, or manipulate through the remote controller; the "Pi" sound, the emergency or test operation is terminated. When the remote controller is manipulated, it gets the system back to the normal operation mode. 19
Maintenance
For Smart Use of The Air Conditioner
Setting of proper room temperature
Proper temperature
Do not block the air inlet or outlet
Close doors and windows Use the timer effectively during operation
During cooling operation, prevent the penetration of direct sunlight with curtain or blind.
If the unit is not to be used Use the louvers effectively for a long time, turn off the power supply main switch.
OFF
20
Maintenance
For Smart Use of The Air Conditioner WARNING
Before maintenance, be sure to turn off the system and the circuit breaker.
Remote Controller
Indoor Body
Do not use water, wipe the controller with a dry cloth. Do not use glass cleaner or chemical cloth.
Wipe the air conditioner by using a soft and dry cloth. For serious stains, use a neutral detergent diluted with water. Wring the water out of the cloth before wiping. then wipe off the detergent completely.
Do not use the following for cleaning
Gasoline, benzine, thinner or cleanser may damage the coating of the unit.
Hot water over 40OC(104OC) may cause discoloring or deformation.
Air Filter cleaning
Open the inlet grille by pulling it upward. Remove the filter.
Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.
Air Filter
Clean the filter.
Use a vacuum cleaner to remove dust, or wash the filter with water. After washing, dry the filter completely in the shade.
Attach the filter.
Attach the filter correctly so that the "FRONT" indication is facing to the front. Make sure that the filter is completely fixed behind the stopper. If the right and left filters are not attached correctly, that may cause defects.
Once every two weeks
Close the inlet grille.
21
Maintenance
Replacement of Air Purifying Filter
1. Open the lnlet Grille
Open the inlet grille by pushing each ends of the inlet grille upward. (use thumbs to push up)
2. Detach the standard air filter
Slide the knob slightly upward to release the filter, then withdraw it.
3. Detach the Air Purifying Filter
Replace the old filter with new one into the frame.
4. Attach new Air Purifying Filter
Attaching each of the Air Purifying Filter to the indoor unit as its white side faces to the front .
5. Attach the standard air filter as its front side faces to the front
Operating without standard air filter may cause troubles with the machine.
6. Close the Inlet Grille
Close the Grille surely
NOTE:
Please replace the air Purifying Filter when color of the filter become same levle of sample attached in the indoor unit. [. . . ]