[. . . ] TIMER Used to select TIMER ON, TIMER OFF, TIMER ON-OFF 21. RESET Used to reset the controller back to normal condition. HEALTH Used to operate the healthy function .
4. SIGNAL SENDING 7. TIMER OFF display
AUTO
LO
MED
HI
7 TIMER OFF display
TIMER ON display SLEEP display
Dry display
NOTE: Cooling only unit do not have displays and functions related with heating If the unit which you purchased has healthy function, follow it. If not, please ignore.
Loading of the battery
2 1 3
Outdoor Unit
1 Remove the battery cover; 2 Load the batteries as
illustrated. [. . . ] Use this switch in the test operation when the room o temperature is below 16 C, do not use it in the normal operation. Pi Pi Continue to press the test operation switch for more than 5 seconds. After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".
3
Operation
Comfortable SLEEP
Before going to bed, you can simply press the SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.
SLEEP Operation
TIMER CLOCK SET SLEEP
1 hours after SLEEP mode starts, temp will become 2OC lower than temp. setting. After another 1 hours, temp decrease by 2 O C further. The unit will run for further 3 hours then stops. setting so that room temperature won't be too high for your sleep.
2. In HEAT mode
Temp. setting 1 hr 1 hr
O
Unit stop
Decreases 2 C
O
Decreases 2 C 3 hrs Rises 1 C 3 hrs SLEEP SLEEP operation stops operation starts In HEAT mode
O
Operation Mode
1. In COOL, DRY mode 1 hours after SLEEP mode starts, temp. The unit will run for further 6 hours then stops Temp. setting so that room temperature won't be too Iow for your sleep. SLEEP operation stops SLEEP operation starts Approx. 6hrs
3. In AUTO mode The unit operates in corresponding sleep mode corresponding sleep mode adapted to the automatically selected operation mode. In FAN mode It has no SLEEP function.
5. When quiet sleeping function is set to 8 hours the quiet sleeping time can not be adjusted. When TIMER function is set, the quiet sleeping function can't be set up. After the sleeping function is set up, if user resets TIMER function, the sleeping function will be cancelled; the machine will be in the state of timing-on, if the two modes are set up at the same time, either of their operation time is ended first , the unit will stop automatically, and the other mode will be cancelled.
1 hr 1 hr
Rises 1 C
O O
Rises1 C
Unit stop Temp. setting In COOL, DRY mode
Power Failure Resume Function
If the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. STRICT ENFORCEMENT
Please call Sales/Service Shop for the Installation. Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.
Use an exclusive power source with a circuit breaker
WARNING
WARNING
Check proper installation of the drainage securely
STRICT ENFORCEMENT
OFF Connect power supply cord to the outlet completely
Use the proper voltage
STRICT STRICT ENFORCEMENT ENFORCEMENT Do not use power supply Take care not to damage the power supply cord. cord in a bundle.
1. Do not use power supply cord extended or connected in halfway 2. Do not install in the place where there is any possibility of inflammable gas leakage around the unit. 3. Do not get the unit exposed to vapor or oil steam. PROHIBITION Do not insert objects into the air inlet or outlet.
PROHIBITION Do not start or stop the operation by disconnecting the power supply cord and so on.
PROHIBITION Do not channel the air flow directly at people, especially at infants or the aged. Do not try to repair or reconstruct by yourself.
PROHIBITION
Connect the earth cable.
PROHIBITION
PROHIBITION
earthing
Do not use for the purpose of storage of Take fresh air occasionally especially Do not operate the switch with food, art work, precise equipment, when gas appliance is running at the wet hand. STRICT ENFORCEMENT Check good condition of the installation stand
CAUTION
PROHIBITION Do not install the unit near a fireplace or other heating apparatus.
PROHIBITION Do not pour water onto the unit for cleaning
PROHIBITION Do not place animals or plants in the direct path of the air flow
PROHIBITION Do not place any objects on or climb on the unit.
PROHIBITION Do not place flower vase or water containers on the top of the unit.
PROHIBITION
PROHIBITION
PROHIBITION
6
Trouble shooting
Before asking for service, check the following first.
Phenomenon The system does not restart immediately. Cause or check points When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system. When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner. [. . . ] 4. The distance between the indoor unit and the floor should be more than 2m. 5. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. . 7. The used batteries should be disposed of properly. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-24LEA03
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.