User manual HAIER HSU12XH7-W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HSU12XH7-W. We hope that this HAIER HSU12XH7-W user guide will be useful to you.

Lastmanuals help download the user guide HAIER HSU12XH7-W.


Mode d'emploi HAIER HSU12XH7-W
Download

You may also download the following manuals related to this product:

   HAIER HSU12XH7-W annexe 1 (7861 ko)

Manual abstract: user guide HAIER HSU12XH7-W

Detailed instructions for use are in the User's Guide.

[. . . ] Place, where discharged wind and noise do not cause a nuisance to the neighbors. Place, where a distance marked Q is available as illustrated in the above figure. Drawing for the installation of indoor and outdoor units The models adopt HC FC free refrigerant R410A Attention must be paid to the rising up of drain hose more than 5cm Optional parts for piping A Non-adhesive tape B Adhesive tape more than 10cm G C Saddle (L. S) with screws Connecting electric cable D for indoor and outdoor E Drain hose F Heating insulating material G Piping hole cover Arrangement of piping directions Rear left Left Rear right Right Below more than 10cm F A Floor fixing dimensions of the outdoor unit (Unit:mm) For 18K 113. 5 C 633 113. 5 more than10cm more than 10cm 184 For 24K 580 184 The marks from A to G in the figure are the parts numbers. The distance between the indoor unit and the floor should be more than 2m. [. . . ] Connecting the pipe of gas side first makes working easier. The connection pipe is specialized for R410A. Half union Flare nut Forced fastening without careful centering may damage the threads and cause a leakage of gas. Pipe Diameter() Liquid side6. 35mm(1/4") Fastening torque 18N. m 42 N. m 55N. m 60 N. m Indoor unit Connecting wiring: AWG18X6, Power Cable: AWG12X3. Outdoor unit Liquid/Gas side9. 52mm(3/8") Gas side 12. 7mm(1/2") Spanner Torque wrench Gas side 15. 88mm(5/8") SN-18000-H Ensure that on dirt or debris enters the pipe. If it is over 7m, the function of the unit will be affected. If the pipe has to be lengthened, the refrigerant should be charged, according to 50 g/m. But the charge of refrigerant must be conducted by professional air conditioner engineer. Before adding additional refrigerant, perform air purging from the refrigerant pipes and indoor unit using a vacuum pump, then charge additional refrigerant. CAUTION Outdoor unit B A Indoor unit B Indoor unit A Outdoor unit Outdoor unit B Oil trap Indoor unit A Indoor unit Connecting wiring: AWG18X6, Power Cable: AWG12X3. Outdoor unit Connection Max. Elevation: Amax=15m In case the elevation A is more than 5m, oil trap shoud be installed every 5~7m Max. Length: Bmax=25m = In case the pipe length B is more than 7m, the refrigerant should be charged, according to 20 g/m. (for 18k) In case the pipe length B is more than 7m, the refrigerant should be charged, according to 50 g/m. (for 24k) SN-24000-H 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F. If the fuse on PC board is broken please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Take off the panel(top), by removing the 5 screws. Temporarily mount the conduit tubes on the conduit plate. Connect both the power supply and unit wire harness to the corresponding terminals on the terminal board. [. . . ] Is the connecting wiring of indoor and outdoor firmly fixed?Is power source voltage abided by the code?Are cooling and heating (when in heat pump) performed normally? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU12XH7-W

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU12XH7-W will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag