User manual HAIER HUM18HA03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HUM18HA03-R2. We hope that this HAIER HUM18HA03-R2 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HUM18HA03-R2.


Mode d'emploi HAIER HUM18HA03-R2
Download
Manual abstract: user guide HAIER HUM18HA03-R2

Detailed instructions for use are in the User's Guide.

[. . . ] The power source is the same as the corresponding name plate. Install an exclusive branch circuit of the power. A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it. Selection of pipe To this unit, both liquid and gas pipes shall be insulated as they become low temperature in operation. [. . . ] If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is H05RN-F or H07RN-F. If the fuse on PC board is broken please change it with the type of T. The wiring method should be in line with the local wiring standard. After installation, the power plug should be easily reached. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the distance between its two contacts should be not less than 3mm. Outdoor unit 1(N) 2(L) 3(C) 4G0. 75mm2 1(N) 2(L) 3(C) Indoor unit HSM09HEA03/R2(DB) HSM12HEA03/R2(DB) HSM18HEA03/R2(DB) POWER { 1 (N) 2 (L) 3 (C) 2(N) 1(L) Outdoor unit 4G0. 75mm2 Indoor unit POWER { Power cable: 09-12: 3G1. 5mm2 18-22: 3G2. 5mm2 HSM22HEA03/R2(DB) 5 Outdoor unit 1. Installation of Outdoor Unit Install according to Drawing for the installation of indoor and outdoor units 2. Connection of pipes To bend a pipe, give the roundness as large as possible not to crush the pipe , and the bending radius should be 30 to 40 mm or longer. Connecting the pipe of gas side first makes working easier. The connection pipe is specialized for R410A. Flare nut Forced fastening without careful centering Half union may damage the threads and cause a leakage of gas. Pipe Diameter ( ) Fastening torque 18N. m 40N. m 55N. m Liquid side 6. 35mm(1/4") Spanner Torque wrench Gas side 9. 52mm(3/8") Gas side 12. 7mm(1/2") Be careful that matters, such as wastes of sands, etc. 2-way valve 3-way valve Valve rod cap After attaching the each caps, check the gas leakage around the caps. CAUTION: 1. If the refrigerant of the air conditioner leaks, it is necessary to discharge all the refrigerant. Vacuumize first, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate. 2. Please do not let other cooling medium, except specified one (R410A), or air enter into the cooling circulation system. Otherwise, there will be abnormal high pressure in the system to make it crack and lead to personal injuries. Service port cap Valve rod cap 1. Power Source Installation The power source must be exclusively used for air conditioner. (Over I0A) In the case of installing an air conditioner in a moist place, please install an earth leakage breaker. For installation in other places, use a circuit breaker as far as possible. 2. Cutting and Flaring Work of Piping Pipe cutting is carried out with a pipe cutter and burs must be removed. After inserting the flare nut, flaring work is carried out. A Flare tooling die 1. Cut pipe 2. Remove burs Flare tool for R410A Clutch-type Conventional flare tool clutch-type(Rigid-type) Wing-nut type (Imperial-type) 0~0. 5mm 1. 0~1. 5mm 1. 5~2. 0mm 3. Insert the flare nut Correct Incorrect 4. Flare pipe Lean Damage of flare Crack Partial Too outside 3. On Drainage Please install the drain hose so as to be downward slope without fail. Please don't do the drainage as shown below. Less than 5cm It becomes high midway. The gap with the ground is too small There is the bad smell from a ditch Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out surely to outdoor. [. . . ] A B C D E F contiene gas fluorurati ad effetto serra inclusi nel protocollo di Kyoto carica di refrigerante di fabbrica del prodotto: vedi targhetta con il nome dell'unità quantità di refrigerante aggiuntiva nel campo carica di refrigerante totale unità esterna cilindro del refrigerante e collettore di carica Questo prodotto contiene gas fluorurati ad effetto serra inclusi nel Protocollo di Kyoto. Non liberare tali gas nell'atmosfera. Tipo di refrigerante: R410A Valore GWP*: 1975 *GWP = potenziale di riscaldamento globale Compilare con inchiostro indelebile, ·1 la carica di refrigerante di fabbrica del prodotto ·2 la quantità di refrigerante aggiuntiva nel campo e · 1+2 la carica di refrigerante totale sull'etichetta di carica del refrigerante fornita con il prodotto EN IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED The filled out label must be adhered in the proximity of the product charging port (e. g. onto the inside of the stop valve cover). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HUM18HA03-R2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HUM18HA03-R2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag