User manual HAIER HW-07C03/R1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER HW-07C03/R1. We hope that this HAIER HW-07C03/R1 user guide will be useful to you.

Lastmanuals help download the user guide HAIER HW-07C03/R1.


Mode d'emploi HAIER HW-07C03/R1
Download
Manual abstract: user guide HAIER HW-07C03/R1

Detailed instructions for use are in the User's Guide.

[. . . ] ", fan motor runs at low speed to blow out gentle air. ", air conditioner will start cooling at low speed, blowing out gentle air. ", air conditioner will start speedy cooling, blowing out strong air. ", air conditioner stops running. <3> When set to " <4> When set to " <5> When set to " Hint When the mode selection switch is turned to " " or " the air conditioner will only blow out air without cooling. ", If the mode selection switch is turned from cooling mode to fan mode, do not turn it back until at least 3 minutes have elapsed. 4 Operation Guide Thermostat switch This switch controls the preset indoor temperature to make the air conditioner start or stop automatically, so as to reduce power consumption and operate the system both comfortably and economically. [. . . ] Remark: The compressor stops running when the set temperature is reached but the fan continues to operate to keep an even indoor temperature. Vertical Airflow Direction Vane (Airflow direction adjustment Up-and-Down) The Vertical Airflow Direction Vane is manually controlled by positioning the vane to discharge the air upward, downward or straight out. Vertical airflow direction Note: It is advisable not to keep horizontal flap at downward position for a long time in COOL or FAN mode, otherwise , condensate water might occur. Don't move the vertical flap with hand in order to avoid the vertical flap abnormal, using the remote controller to adjust the move of vertical flap. CAUTION In cooling mode, after you turn thermostat switch counter-clockwise, do not turn it back until at least 3 minutes have elapsed. Otherwise, the fuse may blow due to overload. Do not exceed the selection range. 5 Maintenance Air filter cleaning (before cleaning, turn off the power) When dirt accumulates on air filter, air circulation will be blocked, which causes poor cooling. It is advisable to clean air filter every two weeks for longer operation. Take out the air filter . Press the concave parts on both sides at 1 the lower part of air inlet grille to open the air inlet grille. As illustrated, remove the screw at the left 2 corner of the air filter. Hold the two white humps of filter mesh with 3 fingers (as illustrated) and take it out. Gently flap the dirt off the air filter. Carefully wash air filter in warm water (below 40*). To obtain better cleaning effect, soap water or neutral detergent may be used. Temperature should be set properly when there are infant, child, the aged or disabled in the room. Go away! Baby has gone sleep, better to adjust suitable temp. Before operating mode selection switch, check that if the air inlet or outlet have been blocked. For longer and trouble-free operation of the unit, pay special attention to the following: Install air-con at a place strong enough to support the unit. Leave enough space around air inlet and outlet for better circulation. Problems may occur if unit is installed in the following places: Place where oil exists in the air including engine oil or seaside with salt breeze blows and hot spring area with sulphurous gas in the air. 10 Installation Guide Selection of the installation position 1. The air-conditioner is better installed in shadow or in a place with short period of sunshine. In case the air-conditioner is installed at the point exposed directly to the sunshine, it should be protected from the direct sunlight as possible in order to avoid the long time of direct sunlight otherwise its performance will be lowered. For the convenience of operation, it is recommended that air-conditioner be installed at least at the height of 760-1300 mm above the floor and no obstacles before it for a free airflow. The shutters at both sides and the top of air-conditioner should be protruded outdoors free from being blocked by wall, window, etc. The back of air-conditioner should be kept over 500mm from the obstacles (for example, wall, etc. ) (As illustrated in Fig. To have an efficient drainage, the back part of the air-conditioner should be inclined downward by 5-10mm (As illustrated in Fig. 3). cover m0m15 support fig. 1 >500mm fig. 2 fig. 3 The enclosed accessories of the conditioner are: Name Manual Outlet pipe fitting Sealed gasket Drain pan Screw Figure Quantity 1 1 1 1 2 11 Installation Guide Installation of air-conditioner (only for reference) 1. Make the wall hole or window hole (see Fig. 1). [. . . ] 3). cover m0m15 support fig. 1 >500mm fig. 2 fig. 3 The enclosed accessories of the conditioner are: Name Manual Outlet pipe fitting Sealed gasket Drain pan Screw Figure Quantity 1 1 1 1 2 11 Installation Guide Installation of air-conditioner (only for reference) 1. Make the wall hole or window hole (see Fig. 1). Fix the prefabricated iron frame to stable position by expansible screws. 3. Take out the conditioner and accessories from the package . 350 Iron frame 450 Width of the wall Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HW-07C03/R1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HW-07C03/R1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag