[. . . ] When set to "OFF", air conditioner stops running.
Hint
When the mode selection switch is turned to "HIGH FAN" or "LOW FAN" , the air conditioner will only blow out air without cooling. If the mode selection switch is turned from cooling mode to fan mode, do not turn it back until at least 3 minutes have elapsed.
4
Operation Guide
Thermostat switch This switch controls the preset indoor temperature to make the air conditioner start or stop automatically, so as to reduce power consumption and operate the system both comfortably and economically. Remark: The compressor stops running when the set temperature is reached but the fan continues to operate to keep an even indoor temperature.
Airflow Direction Vane The Vertical Airflow Direction Vane is manually controlled by positioning the vane to discharge the air upward, downward or straight out. The horizontal air direction is adjusted by setting the AUTO SWING switch to the ON position.
Vertical airflow direction
Note: It is advisable not to keep vertical flap at downward position for a long time in COOL or FAN mode, otherwise , condensate water might occur. [. . . ] Don't move the horizontal flap with hand in order to avoid the vertical flap abnormal, using the remote controller to adjust the move of vertical flap.
CAUTION
In cooling mode, after you turn thermostat switch counter-clockwise, do not turn it back until at least 3 minutes have elapsed. Otherwise, the fuse may blow due to overload. Do not exceed the selection range.
5
Maintenance
Air filter cleaning (before cleaning, turn off the power)
When dirt accumulates on air filter, air circulation will be blocked, which causes poor cooling. It is advisable to clean air filter every two weeks for longer operation.
Take out the air filter
1. Press the concave parts on both sides at the lower part of air inlet grille to open the air inlet grille. 2. Hold the hump of filter mesh with fingers (as illustrated) and take it out.
Hump
Air filter cleaning
Cleaning of the air filter
6
Maintenance
Disposal of the condensed water
Generally there are two methods available on disposal of the condensed water: 1. Block the bottom plate hole of the conditioner with rubber lid, install outlet pipe fitting on the back hole and let the condensing water flow from the back hole of the conditioner. (See Fig. 1 ) In this method, the accumulated condensed water in the bottom plate is hit by the fan onto the heat exchanger, and evaporated and blown out from the machine. It can cool the heat exchanger radiator more quickly, and improve the energy efficiency of the conditioner. But the hitting noise by the fan at the outdoor side is relatively large. Problems may occur if unit is installed in the following places: Place where oil exists in the air including engine oil or seaside with salt breeze blows and hot spring area with sulphurous gas in the air.
10
Installation Guide
Selection of the installation position
1. The air-conditioner is better installed in shadow or in a place with short period of sunshine. In case the air-conditioner is installed at the point exposed directly to the sunshine, it should be protected from the direct sunlight as possible in order to avoid the long time of direct sunlight otherwise its performance will be lowered. For the convenience of operation, it is recommended that air-conditioner be installed at least at the height of 760-1300 mm above the floor and no obstacles before it for a free airflow. The shutters at both sides and the top of air-conditioner should be protruded outdoors free from being blocked by wall, window, etc. The back of air-conditioner should be kept over 500mm from the obstacles (for example, wall, etc. ) (As illustrated in Fig. To have an efficient drainage, the back part of the air-conditioner should be inclined downward by 5-10mm (As illustrated in Fig. 3).
support fig. 1
>500mm
fig. 2
5-10mm
cover
fig. 3
The enclosed accessories of the conditioner are:
Name Manual Outlet pipe fitting Sealed gasket
Drain pan Screw
Figure
Quantity
1
1
1
1
2
11
Installation Guide
Installation of air-conditioner (only for reference)
1. Make the wall hole or window hole (see Fig. 1). [. . . ] 3).
support fig. 1
>500mm
fig. 2
5-10mm
cover
fig. 3
The enclosed accessories of the conditioner are:
Name Manual Outlet pipe fitting Sealed gasket
Drain pan Screw
Figure
Quantity
1
1
1
1
2
11
Installation Guide
Installation of air-conditioner (only for reference)
1. Make the wall hole or window hole (see Fig. 1). Fix the prefabricated iron frame to stable position by expansible screws. 3. Take out the conditioner and accessories from the package .
350
Iron frame
450
Width of the wall
Fig. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HW-09HA04
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.