User manual HAIER TME1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HAIER TME1000. We hope that this HAIER TME1000 user guide will be useful to you.

Lastmanuals help download the user guide HAIER TME1000.


Mode d'emploi HAIER TME1000
Download
Manual abstract: user guide HAIER TME1000

Detailed instructions for use are in the User's Guide.

[. . . ] Young children should be supervised to ensure that they do not play with the appliance. · Do NOT use this appliance for other than its intended use. · Do NOT cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit. · Only use this appliance with voltage specified on the rating label. [. . . ] Fit both the sign side panels over the four retaining screws on top of the cabinet. Slide the panels forward, flush with edges of the cabinet, and tighten the retaining screws. Clip the sign rear panel into the retaining slots on the rear of the sign side panels (see Figure 1 below). Lift the sign unit on to the top of the cabinet and connect the sign 3-pole plug into the roof top power supply socket. Clip the sign into the retaining slots on the front of each side panel and pull the sign unit firmly down. Ensure the two screws in the back of the sign unit fit into slots in the cabinet top angle bracket and then tighten all the screws. Turn the sign retaining clips on top of each side panel, to hold the sign unit firmly in position (see Figure 2 below). Sign Retaining Clip Sign Side Panel Sign Rear Panel Retaining Slot Figure 1: Sign Rear Panel Figure 2: Sign Retaining Clip 6 TME650/1000 SKOPE One and Two Door Vertical Chillers 1 INSTALLATION 1. 4 Fitting the Shelves The chiller is supplied with five cabinet shelves, which may be positioned at different heights to suit various products. Depending on the model cabinet, each shelf is held in place with either four or six shelf clips, which engage in the shelf support strips. The support strips are marked with a `+' for easy location of shelf clips. Unpack the shelves and shelf clips from inside the cabinet. Establish the desired position for the shelves and securely engage a shelf clip in each of the shelf support strips (see Figure 3 below). Sit the shelves onto the shelf support clips. Loading Product For even cooling and efficient operation, allow air space around packages etc. Do not allow products to overhang the front of the shelf as this could prevent the doors from shutting or cause glass breakage. Leave an airspace of at least 75mm (3") above product loaded on the top shelf. Shelf Support Strip Shelf Shelf Clip `+' Mark Figure 3: Shelf Clip TME650/1000 SKOPE One and Two Door Vertical Chillers 7 2 OPERATION 2. 1 Cabinet Operation Connect the cabinet to the mains power supply and check operation of the refrigeration unit and cabinet lighting. NOTE: After moving the chiller, allow the cabinet to stand for at least 30 minutes before connecting to the power supply. Refrigeration Unit The compressor, and evaporator and condenser fans should all operate continuously from the time the cabinet is plugged in. This may be verified by listening for compressor switch on and checking for air movement inside the cabinet. The compressor and condenser fans should switch off when the cabinet internal temperature reaches approximately 2°C. The internal cabinet air will continue to circulate at all times. Lighting The sign light and cabinet interior lights will go on when the cabinet is plugged in, and will stay on permanently. The fluorescent lights will require a period of time to stabilise following initial start up. 8 TME650/1000 SKOPE One and Two Door Vertical Chillers 3 MAINTENANCE 3. 1 Lighting Cabinet Interior lights Depending on the model cabinet, the chiller has either one or two interior side lights. Each side light houses a 35 Watt T5 fluorescent tube (Ø16mm x 1450mm), which may be replaced without removing shelves or product from the cabinet. To replace the interior side light fluorescent tube: 1. Disconnect the cabinet from the mains power supply. [. . . ] Disconnect the cabinet from the mains power supply. Loosen the sign retaining clip on the top of each side panel and lift the sign unit up, to disengage from the sign sides. Disconnect the sign plug from the electrical box socket and remove the sign unit from the cabinet. The condenser coil is now accessible for cleaning. Condenser Coil Sign Plug Socket Figure 7: Cleaning the Condenser Coil TME650/1000 SKOPE One and Two Door Vertical Chillers 11 3 MAINTENANCE 3. 3 Advanced Servicing Advanced servicing should be carried out by an authorised service agent. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER TME1000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER TME1000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag