Detailed instructions for use are in the User's Guide.
[. . . ] If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. These instruments are in compliance with the directives.
SPECIFICATIONS
Range 0. 0 to 14. 0 pH Resolution 0. 1 pH Accuracy (@ 20°C/68°F) ±0. 2 pH Typical EMC Deviation ±0. 1 pH Calibration Manual, through CAL (Offset) trimmer Dosing Contact Maximum 2A (fuse protected), 250 Vac, 30 Vdc Dosing Selection Acid or Alk, selectable on the back panel Contact Open=Acid dosage=Relay ON if Measure > Setpoint Contact Close=Alk dosage=Relay ON if Measure < Setpoint Setpoint Adjustable, from 0 to 14 pH Overtime Adjustable, typically from 5 to approx. 30 minutes Power Consumption 10 VA Installation Category II Power supply: External (fuse protected) BL981411-0 12 Vdc BL981411-1 115/230 Vac ; 50/60Hz Dimensions 83 x 53 x 99 mm (3. 3x2. 1x3. 9")
ACCESSORIES
pH CALIBRATION SOLUTIONS HI 7006M/L pH 6. 86 buffer solution, 230/500 mL bottle HI 7007M/L pH 7. 01 buffer solution, 230/500 mL bottle OTHER SOLUTIONS HI 70300M/L Electrode storage solution, 230/500 mL bottle HI 7061M/L Electrode general cleaning solution, 230/500 mL HI 7073M/L Protein cleaning solution, 230/500 mL bottle HI 7074M/L Inorganic cleaning solution, 230/500 mL bottle HI 7077M/L Oil & Fat cleaning solution, 230/500 mL REFILLING ELECTROLYTE SOLUTIONS (50 mL, 4 pcs. ) HI 7071 3. 5M KCl+AgCl, for single junction electrodes HI 7072 1M KNO3 solution HI 7082 3. 5M KCl, for double junction electrodes pH ELECTRODES HI 1002/5 BNC connector, double junction, plastic-body w/external thread & 5 m (16. 5') cable HI 1090T Screw connector, double junction, glass-body with external thread HI 1110S Screw connector, single junction, glass-body HI 1210T Screw connector, double junction, plastic-body with external thread HI 2114P/2 BNC connector, double junction, plastic-body with 2 m (6. 6') cable HI 1210B/5 BNC connector, double junction, plastic-body, with 5 m (16. 5') cable HI 2910B/5 BNC connector, double junction, plastic-body, with built-in amplifier and 5 m (16. 5') cable EXTENSION CABLES, SCREW TO BNC CONNECTOR HI 7855/5 Extension cable 5 m (16. 5') long HI 7855/10 Extension cable 10 m (33') long OTHER ACCESSORIES BL PUMPS Dosing Pumps (flow rate from 1. 5 to 20LPH) HI 6050 Submersible electrode holder, 60 cm (24") HI 6051 Submersible electrode holder, 110 cm (43") HI 6054B Electrode holder for in-line applications HI 6054T Electrode holder for in-line applications HI 710005 12 Vdc power adapter, US plug HI 710006 12 Vdc power adapter, European plug HI 731326 Calibration screwdriver (20 pcs) HI 740146 Mounting brackets HI 7871 Level Controller (min and max) HI 7873 Level Controller (min, max and overflow)
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center. [. . . ] Any variation introduced by the user to the supplied equipment may degrade the instrument's EMC performance. To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 24 Vac or 60 Vdc. To avoid damages or burns, do not perform any measurement in microwave ovens.
GENERAL DESCRIPTION
BL981411-0 and BL981411-1 are panel-mounted pH indicators and controllers designed for simplicity of use in a wide range of industrial applications. Connections and wiring to electrode, power supply and contacts are made via the terminal blocks on the rear panel. The meters are equipped with a BNC socket and accept input from conventional pH electrodes. Other features include: overtime control system, selection of dosing direction (Acid/Alk), one dosing contact, multi-colour LED for indicating if the meter is in measurement/dosing/ alarm condition, possibility to set (Off-Auto-On switch) dosing action mode. Two models are available: · BL 981411-0 powered at 12 Vdc · BL 981411-1 powered at 115 or 230 Vac
ASSEMBLING VIEW
FUNCTIONAL DESCRIPTION Front panel
Rear panel
OPERATIONS
REAR PANEL CONNECTIONS Terminals #1, #2 and #3: Electrode · Connect a pH-electrode to the meter BNC plug (#1). · To benefit from the differential input, connect the proper electrode wire (if available) or a cable with a potential matching pin (grounding bar) to the relevant terminal (#3) on the rear panel. Note: When the Matching Pin can not be immersed together with the pH electrode in the solution, disable the differential input by shorting terminals #3 (Matching Pin) and #2 (Electrode Reference) with a jumper wire. Terminals #4: Dosing selection · For acid dosage, leave the circuit open. · For alkaline dosage, short the terminals with a jumper wire. Terminals #5: Not Used Terminals #6: Power Supply · Model BL981411-0: connect the 2 wires of a 12 Vdc power adapter to the terminals +12 Vdc and GND. · Model BL981411-1: connect a 3-wire power cable to the terminals while paying attention to the correct earth (PE), line (L) and neutral (N1 for 115 V or N2 for 230 V) contacts. Terminals #7: Dosing Contact · This contact drives the dosing system, accordingly to the selected setpoint and dosing direction: · if "Acid" dosage is set, the relay is ON and dosing activated if measured value is higher than setpoint; · if "Alk" dosage is set, the relay is ON and dosing activated if measured value is lower than setpoint. Note: The setpoint has a typical hysteresis value comparable to the meter accuracy. Terminals #8: Not Used Overtime system: jumper (#9) and trimmer (#10) · This system allows the user to set a maximum dosing period, by adjusting the rear trimmer from 5 (min) to approx. · When the set time is exceeded, any dosing action stops, the LED indicator on the front panel will blink Red and the LCD will show the "TIMEOUT" warning message. To exit the overtime condition, set the OFF/Auto/ON switch to "OFF" position, and then to "Auto" again. · For disabling the overtime feature, simply remove the jumper on the rear panel. Note: The overtime system works only if the OFF/Auto/ON switch is in "Auto" position. [. . . ] "SET" trimmer to adjust the setpoint value (0 to 14 pH) 6. "CAL" trimmer to adjust the pH offset value during calibration 7. 3-colour LED indicator: · Green = meter in measurement mode · Orange/Yellow = dosing in progress · Red, blinking = indicates an alarm condition
5. 10.
BNC plug for pH electrode Connection for electrode reference Connection for potential Matching Pin Acid/Alkaline dosage selection terminal: · contact open = acid selection · contact closed = alkaline selection Not Used contact Power supply terminal: · for BL981411-0 model: 12 Vdc adapter · for BL981411-1 model: 115 Vac or 230 Vac option This contact acts as a switch for driving the dosing system (e. g. [. . . ]