If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS C 101. We hope that this HANNA INSTRUMENTS C 101 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS C 101.
Manual abstract: user guide HANNA INSTRUMENTS C 101
Detailed instructions for use are in the User's Guide.
[. . . ] Instruction Manual
MULTIPARAMETER ION SPECIFIC METERS
Manufacturers since 1978
These Instruments are in Compliance with the CE Directives
Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the meter. This manual will provide you with the necessary information for the correct use of the instrument. If you need additional technical information, do not hesitate to e-mail us at tech@hannainst. com. [. . . ] The reaction between pH and the reagent causes a red tint in the sample. For Iron, Adaptation of the TPTZ Method. The reaction between iron and the reagent causes a blue tint in the sample. For Hardness, adaptation of the Standard Meth21
HI 93744 Hardness/Iron LR/pH
ods for the Examination of Water and Wastewater, 18th edition, Calmagite/colorimetric method. The reaction between hardness and reagents causes a maroon tint in the sample.
REQUIRED REAGENTS
Code HI 93710-0 HI 93746-0 HI 93719A-0 HI 93719B-0 HI 93719C-0 HI 93719D-0 Unit pH Iron LR Hardness Hardness Hardness Hardness
Description Phenol red TPTZ Reagent Ca & Mg indicator Alkali solution EDTA solution EGTA solution
Quantity 5 drops 2 packets 0. 5 mL 0. 5 mL 1 drop 1 drop
REAGENT SETS
HI 93710-01 Reagents for 100 pH tests HI 93710-03 Reagents for 300 pH tests HI 93746-01 Reagents for iron LR (100 packets) HI 93746-03 Reagents for iron LR (300 packets) HI 93719-01 Reagents for 100 hardness tests HI 93719-03 Reagents for 300 hardness tests For other accessories see page 48.
MEASUREMENT PROCEDURES
ON OFF
· Turn the meter on by pressing ON/OFF.
· When the LCD displays "- - - -" keep SET pressed until the desired parameter is displayed.
SET
· Release the key and when the LCD displays "- - -", it is ready. · Refer to the manual pages below to measure the appropriate parameter and for the required reagents:
pH MEASUREMENT
· "PH" will appear on the LCD; then see page 46.
LOW RANGE IRON MEASUREMENT HARDNESS MEASUREMENT
· "FE" will appear on the LCD; then see page 44. · "Hrd" will appear on the LCD; then see page 39.
HI 93744 Hardness/Iron LR/pH
22
HI 93745 pH/Free & Total Chlorine Total Hardness/Iron Low Range
The HI 93745 meter measures the pH, the Magnesium (Mg), Calcium (Ca) and Total Hardness, the Free and Total Chlorine (Cl2) and Iron (Fe) contents in water and wastewater.
SPECIFICATIONS
Range pH Free Cl2 Total Cl2 Fe Mg Hardness Ca Hardness Total Hardness Resolution pH Cl2 Fe Hardness Accuracy pH Cl2 Fe Hardness Typical EMC pH Deviation Cl2 Fe Hardness 5. 9 to 8. 5 0. 00 to 2. 50 mg/L 0. 00 to 3. 50 mg/L 0 to 400 µg/L 0. 00 to 2. 00 mg/L 0. 00 to 2. 70 mg/L 0. 00 to 4. 70 mg/L 0. 1 0. 01 mg/L 1 µg/L 0. 01 mg/L ±0. 1 ±0. 03 mg/L ±3% of reading ±10 µg/L ±8% of reading ±0. 11 mg/L ±5% of reading ±0. 1 ±0. 01 mg/L ±1 µg/L ±0. 02 mg/L
23
HI 93745 Chlorine/pH/Iron LR/Hardness
Light Source Method
Light Emitting Diode @ 555 nm For pH, Phenol red method. The reaction between pH and the reagent causes a red tint in the sample. For Chlorine, adaptation of the EPA recommended DPD method 330. 5. The reaction between chlorine and the reagent causes a pink tint in the sample. For Iron, Adaptation of the TPTZ Method. The reaction between iron and the reagent causes a blue tint in the sample. For Hardness, adaptation of the Standard Methods for the Examination of Water and Wastewater, 18 t h edition, Calmagite/colorimetric method. The reaction between hardness and reagents causes a maroon tint in the sample. Description Phenol red DPD DPD TPTZ Reagent Ca & Mg indicator Alkali solution EDTA solution EGTA solution DPD1 indicator DPD1 buffer DPD1 indicator DPD1 buffer DPD3 solution Quantity 5 drops 1 packet 1 packet 2 packets 0. 5 mL 0. 5 mL 1 drop 1 drop 3 drops 3 drops 3 drops 3 drops 1 drop
REQUIRED REAGENTS
Code Unit HI 93710-0 pH HI 93701-0 Free Cl2 HI 93711-0 Total Cl2 HI 93746-0 Iron LR HI 93719A-0 Hardness HI 93719B-0 Hardness HI 93719C-0 Hardness HI 93719D-0 Hardness Liquid version (chlorine): HI 93701A-F Free Cl2 HI 93701B-F Free Cl2 HI 93701A-T Total Cl2 HI 93701B-T Total Cl2 HI 93701-C Total Cl2
REAGENT SETS
HI 93710-01 HI 93710-03 HI 93701-01 HI 93701-03 HI 93711-01 HI 93711-03 HI 93701-F Reagents for 100 pH tests Reagents for 300 pH tests Reagents for 100 free chlorine tests Reagents for 300 free chlorine tests Reagents for 100 total chlorine tests Reagents for 300 total chlorine tests Reagents for 300 free chlorine tests (liquid version)
24
HI 93745 Chlorine/pH/Iron LR/Hardness
HI 93701-T Reagents for 300 total chlorine tests (liquid version) HI 93719-01 Reagents for 100 hardness tests HI 93719-03 Reagents for 300 hardness tests HI 93746-01 Reagents for iron LR (100 packets) HI 93746-03 Reagents for iron LR (300 packets) For other accessories see page 48.
MEASUREMENT PROCEDURES
· Turn the meter on by pressing ON/OFF.
ON OFF
· When the LCD displays "- - - -" keep SET pressed until the desired parameter is displayed. · Release the key and when the LCD displays "- - -", it is ready.
SET
· Refer to the manual pages below to measure the appropriate parameter and for the required reagents:
FREE CHLORINE MEASUREMENT
· "Cl F" will appear on the LCD; then see page 34.
TOTAL CHLORINE MEASUREMENT
· "Cl t" will appear on the LCD; then see page 36.
pH MEASUREMENT
· "PH" will appear on the LCD; then see page 46.
LOW RANGE IRON MEASUREMENT
· "FE" will appear on the LCD; then see page 48.
HARDNESS MEASUREMENT
· "Hrd" will appear on the LCD; then see page 39.
25
HI 93745 Chlorine/pH/Iron LR/Hardness
C 101 - PH, CL 2, CYS, I, BR, FE
The C 101 meter measures free & total chlorine, cyanuric acid, pH, iodine, bromine and low range iron in water and wastewater.
SPECIFICATIONS
Range pH Free Cl2 Total Cl2 Cyanuric Acid Iodine Bromine Low Range Iron Resolution pH Free Cl2 Total Cl2 Cyanuric Acid Iodine Bromine Low Range Iron Accuracy pH Free Cl2 Total Cl2 Cyanuric Acid Iodine Bromine Low Range Iron Typical EMC pH Deviation Free Cl2 Total Cl2 Cyanuric Acid 5. 9 to 8. 5 0. 00 to 2. 50 mg/L 0. 00 to 3. 50 mg/L 0 to 80 mg/L 0. 0 to 12. 5 mg/L 0. 00 to 8. 00 mg/L 0 to 400 µg/L (ppb) 0. 1 0. 01 mg/L 0. 01 mg/L 1 mg/L 0. 1 mg/L 0. 01 mg/L 1 µg/L ±0. 1 ±0. 03 mg/L ±3% of reading ±0. 03 mg/L ±3% of reading ±1 mg/L ±15% of reading ±0. 1 mg/L ±5% of reading ±0. 08 mg/L ±3% of reading ±10 µg/L ±8% of reading ±0. 1 ±0. 01 mg/L ±0. 01 mg/L ±1 mg/L
26
C 101 pH/Cl/CYS/I/Br/Fe
Iodine Bromine Low Range Iron Light Source Method
±0. 1 mg/L ±0. 01 mg/L ±1 µg/L Light Emitting Diode @ 555 nm For Chlorine, Iodine and Bromine, adaptation of the EPA recommended DPD method 330. 5. For Cyanuric Acid, adaptation of the turbidimetric method. For Iron, adaptation of the TPTZ method. Description Phenol red DPD Reagent DPD Reagent DPD Reagent Powder Reagent TPTZ Reagent DPD1 indicator DPD1 buffer DPD1 indicator DPD1 buffer DPD3 solution Quantity 5 drops 1 packet 1 packet 1 packet 1 packet 2 packets 3 drops 3 drops 3 drops 3 drops 1 drop
REQUIRED REAGENTS
Code Unit HI 93710-0 pH HI 93701-0 Free Cl2 HI 93716-0 Bromine HI 93718-0 Iodine HI 93722-0 Cyanuric Acid HI 93746-0 Iron LR Liquid version (Chlorine): HI 93701A-F Free Cl2 HI 93701B-F Free Cl2 HI 93701A-T Total Cl2 HI 93701B-T Total Cl2 HI 93701-C Total Cl2
REAGENT SET
HI 93701-01 Reagents for 100 free chlorine tests HI 93701-03 Reagents for 300 free chlorine tests HI 93701-F Reagents for 300 free Cl2 tests (liquid version) HI 93701-T Reagents for 300 total Cl2 tests (liquid version) HI 93710-01 Reagents for 100 pH tests HI 93710-03 Reagents for 300 pH tests HI 93711-01 Reagents for 100 total chlorine tests HI 93711-03 Reagents for 300 total chlorine tests HI 93716-01 Reagent for 100 bromine tests HI 93716-03 Reagent for 300 bromine tests HI 93718-01 Reagent for 100 iodine tests HI 93718-03 Reagent for 300 iodine tests HI 93722-01 Reagents for 100 cyanuric acid tests HI 93722-03 Reagents for 300 cyanuric acid tests HI 93746-01 Reagents for Iron LR (100 packets) HI 93746-03 Reagents for Iron LR (300 packets) For other accessories see page 48.
27
C 101 pH/Cl/CYS/I/Br/Fe
MEASUREMENT PROCEDURES
· Turn the meter on by pressing ON/OFF.
ON OFF
· When the LCD displays "C101" keep SET pressed until the desired parameter is displayed.
SET
· Release the key and when the LCD displays "- - -", it is ready. · Refer to the manual pages below to measure the appropriate parameter and for the required reagents:
FREE CHLORINE MEASUREMENT
· "Cl F" will appear on the LCD; then see page 34.
TOTAL CHLORINE MEASUREMENT
· "Cl t" will appear on the LCD; then see page 36.
pH MEASUREMENT
· "PH" will appear on the LCD; then see page 46.
IODINE MEASUREMENT
· "Id" will appear on the LCD; then see page 42.
BROMINE MEASUREMENT
· "br" will appear on the LCD; then see page 32.
CYANURIC ACID MEASUREMENT
· "CYS" will appear on the LCD; then see page 38.
LOW RANGE IRON MEASUREMENT
· "FE" will appear on the LCD; then see page 44.
C 101 pH/Cl/CYS/I/Br/Fe
28
C 104 - PH, CL2 AND CYANURIC ACID
The C 104 meter measures pH, chlorine (Cl2, free and total) and cyanuric acid content in water and wastewater.
SPECIFICATIONS
pH Free Cl2 Total Cl2 Cyanuric Acid Resolution pH Cl2 Cyanuric Acid Accuracy pH Cl2 Cyanuric Acid Typical EMC pH Deviation Cl2 Cyanuric Acid Light Source Method Range 5. 9 to 8. 5 0. 00 to 2. 50 mg/L 0. 00 to 3. 50 mg/L 0 to 80 mg/L 0. 1 0. 01 mg/L 1 mg/L ±0. 1 ±0. 03 mg/L ±3% of reading ±1 mg/L ±15% of reading ±0. 1 ±0. 01 mg/L ±1 mg/L Light Emitting Diode @ 555 nm For chlorine, adaptation of the EPA recommended DPD method 330. 5. For cyanuric acid, adaptation of the turbidimetric method. Description Phenol red DPD
29
REQUIRED REAGENTS
Code HI 93710-0 HI 93701-0 Unit pH Free Cl2 Quantity 5 drops 1 packet
C 104 pH/Cl/Cyanuric A.
HI 93711-0 Total Cl2 HI 93722-0 Cyanuric Acid Liquid version (chlorine): HI 93701A-F Free Chlorine HI 93701B-F Free Chlorine HI 93701A-T Total Chlorine HI 93701B-T Total Chlorine HI 93701-C Total Chlorine
DPD Powder Reagent DPD1 indicator DPD1 buffer DPD1 indicator DPD1 buffer DPD3 solution
1 packet 1 packet 3 drops 3 drops 3 drops 3 drops 1 drop
REAGENT SETS
HI 93701-01 Reagents for 100 free chlorine tests HI 93701-03 Reagents for 300 free chlorine tests HI 93701-F Reagents for 300 free chlorine tests (liquid version) HI 93701-T Reagents for 300 total chlorine tests (liquid version) HI 93710-01 Reagents for 100 pH tests HI 93710-03 Reagents for 300 pH tests HI 93711-01 Reagents for 100 total chlorine tests HI 93711-03 Reagents for 300 total chlorine tests HI 93722-01 Reagents for 100 cyanuric acid tests HI 93722-03 Reagents for 300 cyanuric acid tests For other accessories see page 48.
MEASUREMENT PROCEDURE
· Turn the meter on by pressing ON/OFF. [. . . ] A "V" on the LCD indicates low voltage and the battery should be replaced. If the battery is not replaced immediately, in order to prevent erroneous readings due to low voltage "-BA-" is displayed soon afterwards. At this point, the meter will completely lockup and will not allow any commands and the display will go blank. Battery replacement must only take place in a non-hazardous area using a 9V alkaline battery. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS C 101
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.