If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS EC 214. We hope that this HANNA INSTRUMENTS EC 214 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS EC 214.
Manual abstract: user guide HANNA INSTRUMENTS EC 214
Detailed instructions for use are in the User's Guide.
[. . . ] 4 SPECIFICATIONS EC 214 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 FUNCTIONAL DESCRIPTION EC 215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 SPECIFICATIONS EC 215 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 OPERATIONAL GUIDE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Press the "COND/ C" key to select temperature setting. · Adjust the "TEMPERATURE" knob to display the temperature of the solution on the LCD.
· Select the appropriate conductivity range.
Note: If the display shows "1", there is an over-range condition. · Allow a few minutes for the reading to stabilize. The LCD will display the temperature compensated conductivity reading.
· Press the "COND/ C" key to select conductivity reading. · Select the appropriate conductivity range.
8
9
CALIBRATION
The instrument should be re-calibrated at least once a month, or when the probe is changed.
INITIAL PREPARATION
If you are measuring in the mS ranges, calibrate the meter using HI7030 (or HI8030) conductivity solution (12. 88 mS @ 25 C) or HI7034 (or HI8034) conductivity solution (80 mS @ 25 C). For the µS ranges, use HI7031 (or HI8031) conductivity solution (1413 µS @25 C) when calibrating in the range from 0 to 1999 µS or HI7033 (or HI8033) conductivity solution (84 µS @ 25 C) when calibrating in the range from 0 to 199. 9 µS. Choose a solution with a conductivity value close to the solution to be measured. Rinse the probe thoroughly in distilled water. This is to minimize contamination of the calibration solution and secure higher accuracy. When possible, use plastic beakers to minimize any EMC interferences.
· Press the "COND/ C" key to select conductivity reading and select the appropriate range: "199. 9 µS" for HI7033/HI8033, "1999µS" for HI7031/HI8031, "19. 99 mS" for HI7030/HI8030, "199. 9 mS" for HI7034/HI8034. Note: If the display shows "1", there is an over-range condition. · Allow a few minutes for the reading to stabilize and adjust the "CALIBRATION" knob to read (on the LCD) the value of the buffer solution at 25 C (77 F), e. g. 12. 88 mS/cm.
PROCEDURE FOR EC 214:
· Pour a small quantity of the conductivity solution, e. g. HI7030 or HI8030 (12. 88 mS/cm @ 25 C), into a plastic beaker. · Immerse the probe in the solution submerging the holes of the sleeve (0. 5 cm below). Tap the probe lightly on the bottom of the beaker to remove any air bubbles trapped inside the sleeve. Take the temperature of the solution with a CHECKTEMP or a glass thermometer. · Press the "COND/ C" key to select temperature setting. · Adjust the "TEMPERATURE" knob to display the temperature of the solution on the LCD.
· All subsequent measurements will be referenced to 25 C (77 F). · To reference the measurements to 20 C (68 F), adjust the "CALIBRATION" knob to read (on the LCD) the value of the buffer solution at 20 C (68 F), e. g. · Calibration is now complete and the instrument is ready for use.
0 703 HI
PROCEDURE FOR EC 215:
· Pour a small quantity of the conductivity solution, e. g. HI7030 or HI8030 (12. 88 mS/cm @ 25 C), into a plastic beaker. [. . . ] Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.
CE DECLARATION OF CONFORMITY
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. The metal band at the end of the sensor is sensitive to electrostatic discharges. Avoid touching this metal band at all times. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS EC 214
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.