Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual HANNA INSTRUMENTS HI 142. We hope that this HANNA INSTRUMENTS HI 142 user guide will be useful to you.
Lastmanuals help download the user guide HANNA INSTRUMENTS HI 142.
You may also download the following manuals related to this product:
HANNA INSTRUMENTS HI 142 (180 ko)
Manual abstract: user guide HANNA INSTRUMENTS HI 142
Detailed instructions for use are in the User's Guide.
[. . . ] These instruments are in compliance with the
SPECIFICATIONS
Model HI142AH HI142BH HI142CH HI142DH HI142EH HI142FH HI142GH HI142HH Range Resolution Accuracy ±1. 5°C ±0. 5°C ±0. 5°C ±0. 5°C ±0. 3°C ±0. 3°C ±0. 3°C ±2°C
LED INDICATORS
The status of the logger is indicated by the 2 front LEDs (green and red) as follows: 1. Green LED always ON: the meter has been reset and requires new setting of the parameters. Green LED flashes once every 4": the meter is logging. Green LED flashes twice every 4": the meter is waiting for a delayed logging start. [. . . ] They can all be wired through RS485 to the HI504903 GSM supervisor or to a local PC, allowing data downloading without removing the loggers from their sites. Moreover, with HI504903 GSM supervisor it is possible to receive SMS when an alarm occurs (low/high temperature, low battery level, etc. ) or upon user request. The user can interact with the meters through a PC using the HI92140 Windows® compatible software for setting High and Low alarm thresholds, logging interval, logging delay start, alarm mask time, lot ID, etc. The logger can memorize up to 7600 samples (i. e. stops when memory is full) and can also work in a cyclic way (i. e. old data are replaced by new samples when memory is full). In case of power failure, an internal battery assures a working time of at least 1 week.
OPERATIONAL GUIDE
For connecting the HI142 loggers with the HI504903 GSM supervisor, please refer to the HI504903 instruction manual. It is possible to connect up to 31 units within the same RS485 network with a wires total length up to 1 km. After connection to the GSM supervisor, the user can program and real-time monitor the loggers and also download the data from a PC with the HI92140 software installed. Refer to the on-line-help for further details. The PC can be locally connected to the HI504903 supervisor with a serial cable or can call the HI504903 from remote location through a modem connection. Before starting any operation, activate each logger by pulling the nylon strip in the indicated direction. Simply hang the logger out of the site to be monitored and insert the temperature probe (1. 5 m cable).
TECHNICAL SERVICE
These instruments have been accurately pre-calibrated at the factory; anyway, it is generally recommended to have all thermometers recalibrated at least once a year. For an accurate recalibration, contact the nearest Hanna Customer Service Center. If necessary, contact the nearest Hanna Customer Service Center also for replacement of internal backup battery and/or temperature probe.
Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice.
CONNECTION CABLES
For connecting the first HI142 datalogger to the HI504903 supervisor, make a cable for both RS485 and power supply connections. A 4-wire cable and an RJ11 jack (male connector) are necessary, then follow the below diagram: For connecting the HI142 datalogger network to a local PC and to external power supply, make a cable following the below diagram and plug it to either RJ11 female connector on the logger. Necessary material: a 4-wire cable, an RJ11 jack (male connector), a 12 VDC adapter and an RS485 adapter with Send Data Control connected to PC.
ACCESSORIES
HI 504903-1 GSM Supervisor (dual-band 900/1900 MHz; with 115 Vac to 12 Vdc adapter) HI 504903-2 GSM Supervisor (dual-band 900/1800 MHz; with 230 Vac to 12 Vdc adapter) HI 710005 115 Vac to 12 Vdc adapter, US plug HI 710006 230 Vac to 12 Vdc adapter, European plug HI 92140 Windows® compatible software
SALES & TECHNICAL SERVICE CONTACTS
Australia:
Tel. (03) 9769. 0666 · Fax (03) 9769. 0699
China:
Tel. (10) 88570068 · Fax (10) 88570060
Egypt:
Tel. & Fax (02) 2758. 683
Germany:
Tel. [. . . ] 6296. 7118 · Fax 6291. 6906
South Africa:
Tel. (011) 615. 6076 · Fax (011) 615. 8582
Taiwan:
Tel. 886. 2. 2739. 3014 · Fax 886. 2. 2739. 2983
Thailand:
Tel. 66-2 619-0708 · Fax 66-2619-0061
United Kingdom:
Tel. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HANNA INSTRUMENTS HI 142
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual HANNA INSTRUMENTS HI 142 will begin.